Turbidity and Photometric Detector Modules for Water Analysis Turbidity is a scattered light measurement, and the number a plant reports depends on the wavelength, the angle and the standard the sensor was checked against. The modules below use an 860 nm source at 90 degrees, which is the geometry ISO 7027 asks for, and they report in NTU or FNU. Ranges run from 0 to 10 NTU on a drinking water point to 0 to 4,000 NTU on a sludge line, and each one is quoted with its accuracy at that range. Each entry also lists the flow or immersion requirement, because a turbidity sensor that sits in a dead pocket reads the pocket and not the water.
Solenoid and Pinch Valves for Fluid Handling in Analysers A valve in an analyser does one of two jobs: it isolates a reagent from a cell, or it lets a sample flow through a tube that must not touch metal. The parts below split along that line. A direct acting solenoid valve gives a fast, small, repeatable seat with a metal or plastic body. An air operated pinch valve closes by squeezing a sleeve, so the liquid only meets the sleeve and the flow path is straight through. Both are quoted with orifice, pressure range and wetted material, because those three decide whether a valve can sit in the fluid path at all.
Gas Mass Flow Sensors for Ventilators and Analysers A ventilator or a gas analyser has to know how much gas moved, not how fast the pressure changed. The sensors below are thermal mass flow meters with a calibrated digital output, so the host reads standard litres per minute instead of a raw bridge voltage. Flow ranges run from 20 slm on a gas mixing sensor to 300 slm on an inspiratory channel, and each one is quoted with its pressure drop at the flow that matters. Ranges are listed with accuracy per band, because the error grows at the top of a range and a single percentage hides that.
Peristaltic and Diaphragm Micro Pumps for Analysers A metering pump decides how much reagent reaches the cell, and that number is what the analyser reports. The pumps below cover two families: peristaltic heads that move liquid inside a disposable tube, and diaphragm heads that move it with a valve and a moving membrane. Flows run from 18 ml per minute on a small diaphragm head to 800 ml per minute, and the tube pumps go higher again on a 4.8 mm bore. Each entry lists the head, the pressure it holds and the suction height, because those three figures pick the pump long before the flow figure does.
Water Quality Sensor Circuits for pH, Conductivity and Dissolved Oxygen A water quality analyser is a probe plus a small computer, and the computer is the part that decides whether the reading holds its accuracy. The circuits below take pH, conductivity, dissolved oxygen, redox and platinum RTD probes and return a finished value over UART or I2C. Each one is calibrated in one, two or three points and each carries its own ISO reference for the quantity it reads. They run from 3.3 V to 5 V on a 14 by 20 mm board, which is small enough to sit inside a probe head rather than in a cabinet.
Infrared Thermopile Temperature Sensors for Non Contact Measurement A thermopile turns the infrared energy of a surface into a voltage, and the field of view decides how much of that surface is averaged. The digital parts carry a 17 bit converter, so the reading arrives over SMBus or I2C at 0.02 C resolution without an external amplifier. Fields of view run from 90 degrees for a close surface to 5 degrees for a target a metre away, and the spot size follows the half angle. Medical accuracy versions hold plus or minus 0.2 C around body temperature, which is a different part number, not a calibration step.
Oxygen Sensor Cells for Ventilators and Oxygen Concentrators An oxygen cell in the inspiratory limb turns partial pressure into a small voltage, and the ventilator alarms are set against that voltage. Galvanic cells need no supply and give 10 to 15.5 mV in air, with T90 from 5 to 60 seconds depending on the model. Optical cells output 0 to 25 percent over a 3.3 V UART and do not deplete, which suits instruments that sit idle for months. Every row below carries the output at 21 percent O2, because that is the number the calibration is checked against.
Level Sensors and Float Switches for Tanks and Sumps A float switch is a reed contact inside a stem and a magnet inside a float, so it needs no supply and no signal conditioning. The 25 VA family switches 0.6 A at 240 V AC, and the 100 VA family 1 A at 300 V AC or DC. Bodies come in nylon, polypropylene, PPS and PVDF, with M12 by 1.75 or 1/8 NPT mounting. External fitting versions mount through a tank wall from outside, where the inside is not accessible.
Differential Pressure Sensors for Ventilators and Process Lines A ventilator measures flow by measuring the pressure drop across a fixed restriction, so the sensor has to resolve a few pascal. The 125 Pa and 500 Pa bodies hold a zero point accuracy of 0.08 and 0.1 Pa, with no measurable drift. Response is under 3 ms and the digital versions sample at 2 kHz, which is faster than the breathing cycle needs. Ranges run from 125 Pa through 2 kPa, in manifold mount, tube connection and reflow solderable bodies.
Liquid Flow Sensors for Medical and Analytical Instruments A thermal liquid flow sensor measures through the wall of the channel, so nothing sits in the fluid path. Four ranges cover 2 ml per minute, 40 ml per minute, 600 ml per minute and 1000 ml per hour for single use lines. Response time is below 20 ms, which is what a dosing loop needs to close on a valve rather than on an average. Output is I2C or RS485, calibrated for water and for IPA, with an air in line flag on the digital versions.
IEC 60601 Power Supplies for Medical Diagnostic Equipment A medical supply is chosen on leakage current and isolation before it is chosen on watts. The 65 to 300 W open frame family carries 2xMOPP between primary and secondary, with 4 kVAC isolation. Earth leakage runs from 130 to 190 uA depending on series, and touch current from 40 to 100 uA. All of them accept 80 to 264 VAC and run from minus 30 to plus 70 C, with a 3 year warranty.
Split Core Current Transformers for Retrofit Metering A split core transformer clamps around a cable that is already installed, so a metering point is added without cutting the conductor. The family runs from 200 A through a 0.75 inch opening to 3000 A through a 3 inch opening. Output is 0.333 V AC at rated current, which is a voltage signal that does not need a shorting switch. Accuracy is plus or minus 1 percent from 10 to 130 percent of rated current, class 1.0 to IEC 61869-2 on the larger frames.
CT Test Terminal Blocks and Shorting Links A current transformer secondary must never be opened under load, so the test point has to short before it separates. Test disconnect blocks do that inside one 8.2 mm body, with a 4 mm socket on each side of the break. Rated 41 A on a 6 mm2 conductor and 57 A on 10 mm2, with 0.72 to 1.2 kA short time current. Shorting links and switching jumpers complete a three phase set without handling the CT wiring.
Earth Fault Relays for Resistance Grounded Systems A resistance grounded system limits earth fault current, so the relay has to work with a few amps instead of a few thousand. Trip levels run from 0.5 to 4 A on the compact relays, and 2 to 100 percent of the CT primary on the monitoring types. Trip time is adjustable from 0.1 to 10 seconds, with harmonic filtering so a drive does not trip the feeder. The same unit watches the neutral grounding resistor, because an open resistor leaves the protection blind.
Voltage Transformers for Panel Metering and Protection A voltage transformer brings 415 V down to 110 V so a meter or a relay can read the line without touching it. Three phase units run 25 to 200 VA at class 0.5 or class 1, with a 1.9 voltage factor for eight hours. Residual winding types give 110/110 V for broken delta earth fault detection on the same footprint. Single pole units go up to 36 kV system voltage where the metering point sits on a medium voltage board.
Insulation Fault Locators for IT Systems An insulation fault locator finds which outgoing circuit in an unearthed system has the fault, not only that a fault exists. Each unit reads twelve measuring current transformers, and fifty units on one bus cover 600 circuits. Sensitivity is 2 to 10 mA for main circuits and 0.2 to 1 mA for control circuits and medical locations. The locating current is injected by the insulation monitor or by a separate injector, so the locator works with the monitoring system already in the panel.
Protection Current Transformers for Overcurrent Relays A protection transformer has to hold its ratio while a fault current runs, not only at rated current. This range covers 100/5 to 5000/5 in class 5P10 and 5P20, with burdens from 2.5 to 35 VA. The accuracy limit factor is quoted at rated burden, so the actual burden decides the real factor. Windows run from 40 to 180 mm, which covers cable primaries and busbar primaries in low voltage panels.
Rogowski Coil Current Sensors for Retrofit Metering A Rogowski coil has no iron core, so it reads a busbar from a few hundred amps to 15,000 A without saturation. The coil opens at the connector and closes around a cable or bar that cannot be disconnected. Output is 0.070 V per 1,000 A at 60 Hz, and a meter with a Rogowski input or an external integrator scales it. Linearity is 0.5 % from 100 A to 15,000 A, and phase displacement stays under 0.5 degrees for power readings.
Neutral Grounding Resistors for Resistance Grounded Systems A neutral grounding resistor limits the current that flows when one phase touches earth, so the fault is detected without destroying the transformer. The range covers 240 V to 72 kV systems, with current ratings up to 5000 A and duty from ten seconds to continuous. Time rating and temperature rise are the two numbers that size the resistor, and both come from IEEE 32. High resistance grounding on a 600 V system holds the fault current under 25 A and lets the plant run until the fault is located.
Metering Current Transformers for Panel and Switchgear A metering transformer steps the feeder current down to 5 A so a meter or a relay can read it without breaking the circuit. The range covers 100, 150 and 200 A primaries with a 21 mm cable window and a 6 kA thermal rating. Accuracy is class 0.5 at 2 VA, class 1 at 2.5 VA and class 3 at 3.5 VA, so the burden decides the class that is reached. The transformer class sets the accuracy of the whole metering point, whatever the meter is rated.
Multifunction Power Meters and Power Quality Analyzers A multifunction meter replaces the row of single function instruments on a panel door with one unit that measures voltage, current, power, power factor and energy. Accuracy runs from class 0.5S for sub metering to class 0.2S for billing and utility reporting. Harmonic analysis reaches the 31st order on the metering types and the 63rd on the billing type. The communication port, the current transformer and the tariff structure decide the model, not the display size.
Static VAR Generators for Dynamic Reactive Compensation A static VAR generator supplies or absorbs reactive current in steps smaller than a kvar, so the compensation follows the load instead of jumping between stages. Units run from 30 to 200 kvar at 400 V, with 480 V and 690 V families on the same frames. Full output is reached within 15 ms, and the target power factor runs from minus one to plus one. The unit is a converter, so it needs a current transformer, an air path and a short circuit protection, and all three decide whether it works.
Capacitor Discharge Reactors and Discharge Modules A discharge reactor brings a capacitor step below 50 V in seconds, so the step can be switched again inside the controller delay. Units cover 230 to 690 V networks and steps from 5 to 100 kvar, in a housing that clips onto a 35 mm rail. Loss is under 1.6 W against the several watts a bank of fixed resistors leaves in the enclosure. One unit per step is the usual arrangement, and the discharge time has to match the controller delay.
Active Harmonic Filters for Low Voltage Networks An active filter measures the harmonic current of the load and injects the same waveform in opposition, so the network sees a clean current. Units run from 40 to 300 A at 380 to 690 V, with harmonic cancellation to the 51st order and a two cycle correction time. The same unit corrects power factor in a quarter cycle and balances current between phases. Sizing follows the harmonic current of the load, not the load current, and the difference is where most oversized quotes come from.
Reactive Power Controllers for Automatic Capacitor Banks The controller reads voltage and current, works out the reactive power and closes the step that brings the power factor back to target. Outputs run from 3 to 12 relay steps, with a 1 A or 5 A current input and a C/k setting that follows the smallest step. Alarm contacts cover overvoltage, undervoltage, over temperature and a target that is not reached. The switching sequence is what separates a good bank from a chattering one, and it is set per installation.
Thyristor Switches for Capacitor Bank Switching A thyristor switch closes a capacitor step at the zero crossing of the current, so the step draws no inrush peak. Modules run from 10 to 100 kvar at 380 to 440 V, with 480 V and 690 V versions for other networks. Reaction time is 5 ms, and every module monitors supply voltage, phase sequence, capacitor output and temperature. Fuse, series reactor and ventilation clearance travel with the module, because those three decide how long the step lives.
Detuned Reactors and Harmonic Filters for Capacitor Banks A reactor in series with each capacitor step moves the resonant frequency below the lowest harmonic in the network, which stops the bank from amplifying it. Three detuning factors cover the common cases: 5.7 percent at 210 Hz, 7 percent at 189 Hz and 14 percent at 134 Hz. Each step is quoted with its inductance, fundamental current, RMS current and losses, because those four set the cable and the fan. The capacitor voltage rating changes with the factor, and that pairing is the point most often missed.
Interface and Coupling Relays for DIN Rail A 6.2 mm housing with one changeover contact at 6 A, so a PLC output drives a valve, a lamp or a small contactor without carrying the load itself. Coils run from 12 V DC to 230 V AC, with LED indication and a freewheel diode or bridge rectifier built into the base. The relay plugs into the base, so a failed part is changed without touching the field wiring. Gold contact versions hold 1 mA signals, which is what a dry contact or a multiplexer input needs.
Capacitor Switching Contactors for Power Factor Correction Contactors built for capacitor steps, where the closing peak reaches 100 times the running current. Standard AC-6b devices cover peaks up to that limit, and damping resistor versions take an unlimited peak. Ratings run from 12.5 to 100 kvar at 400 V, in 24 V DC and 220 to 230 V AC coils. Fuse, discharge and ambient derating sit next to each rating, because those three decide how long the contactor lasts.
EMC Cable Glands and Shield Clamps for Shielded Cables Brass cable glands that bond a cable shield to the enclosure at the entry, with a brush that touches the braid in one step. Contact resistance is 10 mOhm or less over a 360 degree contact area, which is what a drive cable needs at both ends. Sizes run M16 to M110 with IP68 to 10 bar and IP69 on the metric range, with strain relief to category A. Rail mounted shield clamps from 3 mm to 22 mm are listed for cables that are bonded inside the cabinet.
PV and DC Surge Protective Devices for String Combiners DC surge arresters for the string side of a photovoltaic plant, rated 1000 V or 1500 V continuously. Type 2 modules carry 25 kA to 40 kA at 8/20, and the type 1 version adds 6.25 kA at 10/350 per pole. Short circuit current rating and the open circuit failure mode are stated, because a PV array cannot be switched off. Enclosure versions and DIN rail versions are listed with their protection level and response time.
Photovoltaic Fuse Links for PV Strings and Battery Racks gPV fuse links built for the DC arc of a photovoltaic string, in 1000 V and 1500 V DC ratings. 10 x 38 mm midget bodies cover 1 A to 30 A, and 10 x 112 mm bodies cover 10 A to 25 A for larger strings. Breaking capacity is 20 kA up to 20 A and 50 kA at 25 and 30 A, with ferrule, PCB tab and crimp cap terminals. Pre-arcing I2t and watts loss are listed per part, because string sizing is done on current and on heat.
Surge Protective Devices for Signal and Data Lines Pluggable protectors that sit on a signal pair and clamp the surge before it reaches the input card. A 24 V module carries 10 kA per line at 8/20 and 2.5 kA per line at 10/350, so it covers a zone boundary. Line to line clamping is 45 to 52 V, which is the figure an analogue input is compared against. Series resistance, cut off frequency and capacitance are listed, because a loop has to keep working after the module is fitted.
Anti Condensation Heaters for Electrical Enclosures Small PTC heaters that hold a cabinet a few degrees above the dew point, which is what stops condensation on terminals. Radiant versions from 10 W to 30 W warm a single cold spot, convection versions from 15 W to 150 W warm the whole box. Fan heaters from 200 W to 800 W spread the heat when the cabinet is large or the ambient swings fast. Mounting, inrush current and surface temperature are listed per part, since they decide the fuse and the clearance.
Guard Locking Devices and Solenoid Door Locks Guard locking devices that hold a door shut until the hazard has actually ended, not just until the stop command is given. Holding force runs from 1,000 N on a light process guard to 10,000 N on a heavy machine door. Three families are listed with their coding level, safety rating and the force each mounting position gives. Release options, escape release and manual override are shown per part, because they decide the door hardware.
Contactor Coil Suppression Modules and RC Networks Suppressor modules that sit on the coil terminals of a contactor and cut the switching transient at the source. RC networks hold the peak to 3 x Uc, varistors to 2 x Uc, and diode assemblies remove the peak on DC coils. Voltage bands run from 24 to 48 V, 50 to 127 V, 110 to 240 V and 380 to 415 V AC, with 12 to 250 V DC on diodes. Each type adds a known release delay, which is stated here rather than left to be found on the machine.
Semiconductor and DC Fuses for Drive and Battery Protection aR fuse links that clear a fault before the module sees the let through energy, sized from 40 A to 2250 A. Square body and NH bodies carry the same 690 V AC rating, in four mounting styles for busbar and rail builds. DC ratings are quoted separately: 150 kA at 1000 V DC on the PSR range, 50 kA at 500 V DC on the stud fuse. Pre-arcing and clearing I2t sit on the same row, so a replacement is checked on energy rather than on amps.
Cam Switches and Changeover Switches for Panel Control Rotary cam switches stack contact stages on one shaft and close them in a fixed sequence as the handle turns. Thermal current runs 10 A on the S00 frame, 20 A on the S0 frame and 25 A on the larger S1 frame. Motor ratings are 3 kW, 7.5 kW and 11 kW at 380 to 440 V AC-23A, with 30, 45, 60 and 90 degree angles. Changeover switches add a 20 A mains transfer option with or without a centre off position.
Safety Light Curtains for Machine Guarding Type 4 light curtains that put an infrared screen across an opening and drop two OSSD outputs when a beam is broken. Resolution from 14 mm for finger detection to 40 mm for body detection sets both the protection and the safety distance. Ranges run from 0.1 to 6 m on 14 mm pairs up to 0.1 to 18 m on 30 mm pairs, reduced by mirrors and lens shields. Response time follows the beam count, from 9 ms on a 150 mm pair to 56 ms on a 1.8 m pair.
PTC Thermistor Motor Protection Relays for Winding Temperature Relays that trip on the resistance of PTC sensors buried in the motor windings, not on current. Trip threshold sits at 2.7 to 3.1 kOhm and the reset threshold at 1.1 to 1.65 kOhm, so the contact cannot chatter. Supply is 24 V or 24 to 240 V AC DC on one part, with 1 CO, 1 NO plus 1 NC or 2 CO outputs. ATEX versions, non volatile trip memory and two sensor circuits are listed per part number.