Reflectance and Transmission Probes for Spectrometers Probes that light a sample and read it back through one ferrule. Six illumination fibers around one read fiber, 200 to 600 um cores. Transmission dip probes from 2 to 50 mm pathlength for in line absorbance.
Photomultiplier Tubes and PMT Housings for Spectrometers 28 mm side on tubes for spectroscopy and fluorescence. Multialkali to 900 nm, bialkali to 650 nm, gain of 1.0 x 10^7. Socket assemblies with the divider built in, plus D type sockets.
RTD and Thermocouple Probes for Analyser Blocks Temperature probes built for a block, not for a wall. Pt100 class A in 2, 3 or 4 wire, type K and J thermocouples in class 1. 304 and 316 sheath, M8 to G1/2 threads, sealed or exposed junction.
Diaphragm Vacuum Pumps for Analyser Vacuum Lines Oil free vacuum for sample lines, degassers and filter housings. One stage pumps hold 70 to 160 mbar, two stage pumps reach 1.5 to 7 mbar. PTFE diaphragms and FFPM valves for solvent and acid vapours.
Filter Wheels and Automated Filter Changers Manual and motorized filter wheels for photometric and imaging benches. Six and twelve position wheels for 25.4 mm and 12.5 mm optics. Switching times from 55 ms, with USB, RS-232, TTL and BNC control.
Needle and Metering Valves for Analyser Lines Needle, metering and splitter valves for analyser and LC MS lines. Adjustable flow down to 3.5 uL per minute from a 1 mL per minute inlet. PEEK and PTFE wetted path rated to 800 psi, graduated splitter to 4000 psi. 1/4-28 flat bottom and 10-32 coned ports for 1/16 and 1/8 inch tubing.
Immersion Assemblies and Sample Probes for Online Analysers A pH or conductivity sensor is only as good as the point it sits in. An immersion assembly holds the probe at a depth where the reading is representative, seals the vessel, and lets a technician reach the sensor without draining the tank. The bodies below run from a polypropylene dip tube for an open channel up to a stainless retractable body rated 10 bar at 140 C, with hygienic versions that take 30 minutes of saturated steam at 120 C. Immersion depth runs from 48 mm on a short retractable body to 3,000 mm on a dip tube, and the process connection is a DN 100 or DN 80 flange, an ANSI 3 in flange, or a G 1 1/4 thread. Each line gives depth, pressure, temperature and wetted material together, because the depth that fits a tank and the pressure that fits a pipe rarely come from the same body.
Inline Degassing Modules and Vacuum Degassers for Liquid Lines Dissolved gas leaves a liquid when the pressure drops, so a degasser works by giving the gas somewhere to go before the liquid reaches the detector. The parts below are membrane degassing chambers from 20 to 800 millilitres per minute, with the flow at which each one removes half the dissolved oxygen stated on the line. Each entry gives the flow for 50 percent removal, the fluid volume inside the chamber, the vacuum level and the connections, so a chamber is matched to the pump rather than to the box size. The vacuum side is quoted as a pressure and a volume, because the pump and the chamber are one system and neither works at its rating alone.
Syringe Pumps and Precision Dispensers for Analysers A syringe pump delivers volume by moving a plunger, so the number that matters is not the flow rate but the resolution of that movement. The parts below cover 60 mm stroke OEM pumps from 25 microlitres to 50 millilitres per stroke, with step counts from 6000 up to 384000 on a smooth flow version. Each entry gives resolution, speed range, precision, accuracy and the syringe sizes the frame accepts, so the pump is matched to the volume before it is matched to the protocol. The slowest speed is quoted as a stroke time rather than a flow, because a nanolitre per minute flow is easier to read as hours per stroke.
Rotary and Injection Valves for Analyser Sample Paths A sample path is only as repeatable as the valve that switches it, and the two numbers that decide that are the internal volume and the pressure rating. The parts below cover six port injection valves with 20 microlitre loops rated to 345 bar, and multiposition selector valves from 4 to 16 ports. Each entry gives port count, bore or loop volume, maximum pressure, maximum temperature and the fitting, so the valve is matched to the pump and to the tubing. Loop volume tolerance and the filling method are stated as well, because a nominal 20 microlitre loop does not deliver 20 microlitres.
Conductivity Cells and Toroidal Sensors for Water Analysers A conductivity reading is only as good as the cell constant, and the cell constant is the number that changes when the electrodes foul or the cable is extended. The parts below cover graphite and stainless steel contacting cells from k 0.1 to k 10, and toroidal sensors that reach 2000 mS/cm without any metal touching the sample. Each entry gives cell constant, wetted material, temperature and pressure limits and the fitting, so a cell is chosen for the range and for the pipe it goes into. Temperature compensation is listed with the element type, because a 10 k thermistor and a Pt1000 do not answer the same way at the top of the range.
pH and ORP Electrodes for Process Analysers An electrode that drifts is usually blamed on the glass, but on a process analyser the reference is the part that fails first. The parts below cover steam sterilizable in-line pH sensors with a pressurised reference, sealed gel electrodes for sampling lines, and platinum or gold ORP electrodes for redox control. Each entry lists pH or mV range, temperature and pressure limits, junction type and connector, so the electrode is matched to the process before it is matched to the meter. Slope, offset and response time are given where the maker publishes them, because a two point buffer check only proves the electrode still answers.
Air Bubble Detectors for Infusion and Reagent Lines An air bubble detector is chosen by the smallest bubble it must catch and by the tube it has to clamp, and those two figures decide the principle. The parts below cover ultrasonic transmission sensors from 1.8 mm to 15.5 mm channel width and optical types for 2 to 4 mm tube, with a response time down to 20 microseconds. Every entry lists the bubble size that is detected reliably, the tube outer and inner diameter, the output and the ingress protection. The trade is simple: ultrasound works through opaque tubing and sees a fraction of the inner diameter, optics need a clear tube and see a fixed air gap.
Particulate Matter Sensor Modules for Air Quality Monitors A particulate matter sensor counts and weighs what floats in the air, and the channel list it reports is as important as the accuracy. The modules below use laser scattering with a fan to pull a known volume past the beam, so the reading is a mass concentration in micrograms per cubic metre. One reports six size bins from 0.3 to 10 micrometre, the other reports PM1, PM2.5, PM4 and PM10 plus a number concentration for each. Both are quoted with the sample volume, the response time and the laser class, because those three decide how the reading behaves in a duct.
NDIR and Photoacoustic CO2 Sensor Modules for Medical and Building Use A CO2 module is a light source, a gas cell and a detector, and the number it reports depends on how the baseline is maintained. The modules below cover two optical methods: non dispersive infrared with a long cell, and photoacoustic detection in a small cavity. Specified ranges run from 400 to 2,000 ppm for room air up to 400 to 5,000 ppm for incubators and breathing gas. Each part is listed with its accuracy band, its response time and the self calibration behaviour, because that last figure decides whether a module can be used where fresh air never arrives.
Turbidity and Photometric Detector Modules for Water Analysis Turbidity is a scattered light measurement, and the number a plant reports depends on the wavelength, the angle and the standard the sensor was checked against. The modules below use an 860 nm source at 90 degrees, which is the geometry ISO 7027 asks for, and they report in NTU or FNU. Ranges run from 0 to 10 NTU on a drinking water point to 0 to 4,000 NTU on a sludge line, and each one is quoted with its accuracy at that range. Each entry also lists the flow or immersion requirement, because a turbidity sensor that sits in a dead pocket reads the pocket and not the water.
Solenoid and Pinch Valves for Fluid Handling in Analysers A valve in an analyser does one of two jobs: it isolates a reagent from a cell, or it lets a sample flow through a tube that must not touch metal. The parts below split along that line. A direct acting solenoid valve gives a fast, small, repeatable seat with a metal or plastic body. An air operated pinch valve closes by squeezing a sleeve, so the liquid only meets the sleeve and the flow path is straight through. Both are quoted with orifice, pressure range and wetted material, because those three decide whether a valve can sit in the fluid path at all.
Gas Mass Flow Sensors for Ventilators and Analysers A ventilator or a gas analyser has to know how much gas moved, not how fast the pressure changed. The sensors below are thermal mass flow meters with a calibrated digital output, so the host reads standard litres per minute instead of a raw bridge voltage. Flow ranges run from 20 slm on a gas mixing sensor to 300 slm on an inspiratory channel, and each one is quoted with its pressure drop at the flow that matters. Ranges are listed with accuracy per band, because the error grows at the top of a range and a single percentage hides that.
Peristaltic and Diaphragm Micro Pumps for Analysers A metering pump decides how much reagent reaches the cell, and that number is what the analyser reports. The pumps below cover two families: peristaltic heads that move liquid inside a disposable tube, and diaphragm heads that move it with a valve and a moving membrane. Flows run from 18 ml per minute on a small diaphragm head to 800 ml per minute, and the tube pumps go higher again on a 4.8 mm bore. Each entry lists the head, the pressure it holds and the suction height, because those three figures pick the pump long before the flow figure does.
Water Quality Sensor Circuits for pH, Conductivity and Dissolved Oxygen A water quality analyser is a probe plus a small computer, and the computer is the part that decides whether the reading holds its accuracy. The circuits below take pH, conductivity, dissolved oxygen, redox and platinum RTD probes and return a finished value over UART or I2C. Each one is calibrated in one, two or three points and each carries its own ISO reference for the quantity it reads. They run from 3.3 V to 5 V on a 14 by 20 mm board, which is small enough to sit inside a probe head rather than in a cabinet.
Infrared Thermopile Temperature Sensors for Non Contact Measurement A thermopile turns the infrared energy of a surface into a voltage, and the field of view decides how much of that surface is averaged. The digital parts carry a 17 bit converter, so the reading arrives over SMBus or I2C at 0.02 C resolution without an external amplifier. Fields of view run from 90 degrees for a close surface to 5 degrees for a target a metre away, and the spot size follows the half angle. Medical accuracy versions hold plus or minus 0.2 C around body temperature, which is a different part number, not a calibration step.
Oxygen Sensor Cells for Ventilators and Oxygen Concentrators An oxygen cell in the inspiratory limb turns partial pressure into a small voltage, and the ventilator alarms are set against that voltage. Galvanic cells need no supply and give 10 to 15.5 mV in air, with T90 from 5 to 60 seconds depending on the model. Optical cells output 0 to 25 percent over a 3.3 V UART and do not deplete, which suits instruments that sit idle for months. Every row below carries the output at 21 percent O2, because that is the number the calibration is checked against.
Level Sensors and Float Switches for Tanks and Sumps A float switch is a reed contact inside a stem and a magnet inside a float, so it needs no supply and no signal conditioning. The 25 VA family switches 0.6 A at 240 V AC, and the 100 VA family 1 A at 300 V AC or DC. Bodies come in nylon, polypropylene, PPS and PVDF, with M12 by 1.75 or 1/8 NPT mounting. External fitting versions mount through a tank wall from outside, where the inside is not accessible.
Differential Pressure Sensors for Ventilators and Process Lines A ventilator measures flow by measuring the pressure drop across a fixed restriction, so the sensor has to resolve a few pascal. The 125 Pa and 500 Pa bodies hold a zero point accuracy of 0.08 and 0.1 Pa, with no measurable drift. Response is under 3 ms and the digital versions sample at 2 kHz, which is faster than the breathing cycle needs. Ranges run from 125 Pa through 2 kPa, in manifold mount, tube connection and reflow solderable bodies.
Liquid Flow Sensors for Medical and Analytical Instruments A thermal liquid flow sensor measures through the wall of the channel, so nothing sits in the fluid path. Four ranges cover 2 ml per minute, 40 ml per minute, 600 ml per minute and 1000 ml per hour for single use lines. Response time is below 20 ms, which is what a dosing loop needs to close on a valve rather than on an average. Output is I2C or RS485, calibrated for water and for IPA, with an air in line flag on the digital versions.
Guard Locking Devices and Solenoid Door Locks Guard locking devices that hold a door shut until the hazard has actually ended, not just until the stop command is given. Holding force runs from 1,000 N on a light process guard to 10,000 N on a heavy machine door. Three families are listed with their coding level, safety rating and the force each mounting position gives. Release options, escape release and manual override are shown per part, because they decide the door hardware.
Safety Light Curtains for Machine Guarding Type 4 light curtains that put an infrared screen across an opening and drop two OSSD outputs when a beam is broken. Resolution from 14 mm for finger detection to 40 mm for body detection sets both the protection and the safety distance. Ranges run from 0.1 to 6 m on 14 mm pairs up to 0.1 to 18 m on 30 mm pairs, reduced by mirrors and lens shields. Response time follows the beam count, from 9 ms on a 150 mm pair to 56 ms on a 1.8 m pair.
Foot Switches for Machine Control Foot switches that leave both hands free on presses, tube benders, sewing stations and test benches. Housings run from plastic XPE types at IP66 to die-cast aluminium bodies with a protective shield. Contact blocks are 1 NO plus 1 NC or 2 NC plus 1 NO, with positive opening on the NC side. Momentary and latching versions are both listed, since a machine stop and a jog function are different purchases.
Mechanical Limit Switches for Position Sensing Mechanical limit switches that close or open a contact when a moving part reaches a set position, using a lever, plunger or rod rather than a magnetic field. Bodies cover compact plastic types for tight machine frames and die cast metal types for washdown and heavy handling. Contact arrangements run from one changeover to two normally closed plus one normally open, in snap action or slow action. Safety versions carry a direct opening mechanism on the normally closed contact, which is the feature a guard circuit needs.
Safety Relay Modules for Guard Monitoring Safety relay modules that monitor a guard door, light curtain or E-stop circuit and drop three safety contacts when a channel opens. Dual-channel versions detect cross shorts, broken wires and earth faults in the monitoring circuit. Supply options cover 24 V AC/DC as well as a universal 24 to 240 V AC/DC range in the same 22.5 mm housing. Relay outputs are positive guided, so the auxiliary contact follows the safety contacts for status and feedback.
Door Interlock Switches for Safety Circuits Tongue operated safety switches with 1NC/1NO, 2NC, 2NC/1NO and 3NC contact forms. Slow action contacts with positive opening on the NC side, 10 A thermal current. IP67 bodies in glass fibre reinforced thermoplastic, with M20, M12 or PG13.5 entry. Actuator ordered separately so the approach direction matches the door.
IR Receiver Modules for Remote Control and Data An IR receiver module is a photodiode, a band pass filter and a demodulator in one three pin package, and it outputs a clean logic pulse.\nThe 38 kHz parts here run from 2.5 to 5.5 V, draw about 0.35 mA, and reach 24 m with a 50 mA emitter on the axis.\nHalf transmission angle is plus or minus 45 degrees, and the package is 5.0 x 6.95 x 4.8 mm on the minicast parts.\nAGC2 and AGC4 versions are both listed, because the choice decides which remote codes are accepted in daylight and under lamps.
Photointerrupters and Optical Switches for Position Detection A photointerrupter is chosen on slot width, aperture and output type, because those three set the resolution and the circuit around it. Transmissive parts on this page run from a 2 mm slot in a 5.2 mm tall body to a 5 mm slot 12 mm deep. Reflective parts sense a target at about 3 mm and suit paper, label and flag detection. All of them need a defined aperture or a comparator, and the page states which parts include one.
Reed Switches and Magnetic Actuators for Position Sensing A reed switch is chosen on sensitivity, load and body length, because those three decide the operate distance and the life of the contact. The parts here switch 5 to 20 W at 140 to 200 V DC, with sensitivity bands from 6 to 38 AT. Glass and surface mount versions share the same contact ratings, and the actuator has to be matched to the switch. Each row lists contact form, rating, sensitivity band and body size.
Inductive Proximity and Photoelectric Sensors for Automation A machine builder needs a sensor that repeats, not one that reaches far, so sensing distance and differential travel are read together. The inductive part on this page is an M18 body at 5 mm, and the photoelectric family covers 15 m through beam, 4 m retro reflective and 100 mm diffuse. Output type decides the wiring: NPN or PNP, light on or dark on, three wire at 12 to 24 VDC. Each row lists distance, output, response time and protection class.
RF Detector Diodes and Zero-Bias Schottky Detectors Schottky detector diodes for RF power measurement and receiver level detection. Low barrier parts work without bias current, which keeps the detector noise floor low. Single, series pair and quad configurations are supplied in SOT-23, SOT-143 and 0201. Replacement and long term supply are checked against the maker data sheet.
Time-of-Flight Distance Sensors for Ranging and Presence A time of flight sensor measures the flight time of a short infrared pulse, so the reading depends on distance and not on the colour or the reflectance of the target. Range runs from 60 cm on the smallest part to 5 m on the long range single zone part, and the field of view from 25 degrees to a 65 degree diagonal with 64 zones. Zoned parts report a small depth map, which turns a distance reading into presence detection across a doorway. The 940 nm emitter is class 1, so the module needs no eye safety label of its own when it is used behind a cover glass. Every row lists range, field of view, update rate and interface, because those decide the mounting height and the host bus.
PIR Motion Sensors and Pyroelectric Detector Modules A PIR sensor detects a change in infrared radiation, not motion itself, so a warm body crossing the field produces a pulse while a steady heat source does not. Module level parts such as the HC-SR501 include the comparator, the relay driver and the adjustable delay, so the output is already a logic level. Bare detectors such as the LHI878 need a lens and a signal chain, and they are chosen when the product has its own optics and firmware. Quiescent current runs from about 50 uA on the module to 170 uA on the digital PaPIRs part, which decides whether a battery product can use it. Every row lists supply, current, angle, range and output, because those decide the lens and the power budget.
Hall Effect Switches and Latches for Position Sensing A digital Hall switch reports one bit when a magnet crosses its threshold, so a lid, a valve or a rotor needs no contact and no wear surface. The threshold spread matters more than the typical value: a 4.8 mT maximum operate point on the DRV5032 variants leaves room for magnet tolerance and air gap. Sampling rate sets the current, from 0.54 uA at 5 Hz to 5.2 uA at 80 Hz on the same family. Omnipolar parts respond to either pole, which removes the magnet orientation error from assembly. Each row lists supply, threshold, output type and package, because those decide the magnet and the pull up resistor.
Gas Sensors for Air Quality and Leak Detection Photoacoustic CO2 parts measure 400 to 5000 ppm with an accuracy stated against the reading, not a single number. VOC and NOx index sensors report a 1 to 500 index over I2C and need no gas bottle for calibration. Heated metal oxide cells cover combustible gas and carbon monoxide at the lowest cost per point, with a preheat and a heater cycle. Each row lists range, supply, current and package, because those decide the enclosure and the power budget.