Contact Us

Safety Light Curtains for Machine Guarding

Type 4 light curtains that put an infrared screen across an opening and drop two OSSD outputs when a beam is broken. Resolution from 14 mm for finger detection to 40 mm for body detection sets both the protection and the safety distance. Ranges run from 0.1 to 6 m on 14 mm pairs up to 0.1 to 18 m on 30 mm pairs, reduced by mirrors and lens shields. Response time follows the beam count, from 9 ms on a 150 mm pair to 56 ms on a 1.8 m pair.
quote now

Product Specifications

Product Overview

A safety light curtain is a pair of aluminium bars with no moving parts. The emitter fires a row of infrared beams at the receiver, the receiver checks that every beam arrives in sequence, and two solid state outputs stay energised while the screen is clear. Put a hand or a body into the screen and the outputs drop within the response time, the safety relay opens the stop circuit, and the machine stops. Because there is nothing to walk through and nothing to wear out, a curtain guards an opening that a gate would block and a mat would not cover.

Resolution is the number that decides what the curtain can see. A 14 mm curtain detects a finger and is used where the operator reaches into a hazard, a 23 or 30 mm curtain detects a hand and guards a cell opening, and a 40 mm curtain detects a body and is used where the risk is walking in. Resolution also enters the safety distance calculation. Under ISO 13855 the minimum distance is K multiplied by the total stopping time plus a penetration factor, and for resolutions up to 40 mm that factor is 8 x (resolution - 14), so a 14 mm curtain adds no distance while a 30 mm curtain adds 128 mm.

Range and response time both follow the beam count. A short pair has fewer beams, so it reacts faster and reaches less far; the Banner 14 mm pair reaches 6 m and the 30 mm pair reaches 18 m, while a 14 mm pair at 1.2 m height needs 40 ms and a 150 mm pair needs 11 ms. Mirrors and lens shields cut the range, about 8 percent per glass mirror and 10 percent per lens shield, and the mounting distance has to be calculated with the real response time of the pair that is installed, not the family headline.

Key Specifications

ParameterValueNote
Safety categoryType 4 per IEC 61496-1 and IEC 61496-2PL e and SIL 3 on the Banner LS pair, SIL 3 CL3
Resolution14 mm finger, 23 mm and 30 mm hand, 40 mm bodybeam gap is 10 mm on the 14 mm and 25 mm Omron types
Protective height150 mm to 2.4 m on the Banner SLS, 160 mm to 2.0 m on the Omron 14 mm rangeheight steps of 150 mm on the Banner SLS
Number of beams10 to 240 on the Banner SLS, 15 to 199 on the Omron 14 mm rangebeam count sets the response time
Operating range, 14 mm0.1 to 6 m on the Banner SLS, 0.3 to 10 m on the Omron SRA0.1 to 12 m on the Banner LS 14 mm pair
Operating range, 30 mm0.1 to 18 mrange falls with mirrors and lens shields
Response time9 ms at 150 mm, 23 ms at 600 mm, 40 ms at 1.2 m, 56 ms at 1.8 mBanner SLS figures, ON to OFF
Response time, Omron 14 mm8 to 18 ms with optical synchronization10 to 21 ms with wired synchronization
Outputs2 x OSSD, 24 V DC, 500 mA each on the Banner LSOmron protected output 300 mA, PNP or NPN selectable
Supply voltage24 V DC plus or minus 15 percentOmron 19.2 to 28.8 V DC
Housing protectionIP65 and IP67IP67G on the Omron F3SG-SR
Effective aperture angleplus or minus 2.5 degrees at 3 mType 4 requirement per IEC 61496-2
Ambient temperature-20 to +55 C on the Banner LS-30 to +55 C on the Omron F3SG-SR
Light sourcemodulated infrared, 870 nm on the Omron partimmunity to daylight and to other curtains on the line
ConnectionM12 5 pin or 8 pin pigtail on the Banner LSOmron root connector ordered separately
Safety distanceS = K x T + 8 x (resolution - 14)ISO 13855, T includes machine stop time and curtain response time

Included Models and Order Codes

The table lists the pairs that cover the usual opening sizes rather than every length in the catalogue. On the Banner SLS the pair code carries the resolution and the defined area: SLSP14-600Q88 is a 14 mm pair with a 600 mm protected height and an 8 pin quick disconnect, and the number after the dash is the height in millimetres. The Omron code reads the same way: F3SG-4SRA0320-14 is a Type 4 advanced curtain with a 320 mm protective height and 14 mm detection. Where a height is not listed, the same family is available in 40 mm steps on the Omron side and 150 mm steps on the Banner side, and the beam count moves with the height.

Part numberResolutionProtective heightBeamsResponse timeRangeNote
SLSP14-600Q8814 mm600 mm8023 ms0.1 to 6 mfinger detection, 8 pin quick disconnect pair
SLSP14-900Q8814 mm900 mm12032 ms0.1 to 6 mtaller opening on the same 6 m range
SLSP14-1200Q8814 mm1200 mm16040 ms0.1 to 6 mthe slowest 14 mm pair in the family
SLSP30-600Q8830 mm600 mm4015 ms0.1 to 18 mhand detection, long range
SLSP30-900Q8830 mm900 mm6019 ms0.1 to 18 mcell opening, 18 m reach
SLSP30-1200Q8830 mm1200 mm8023 ms0.1 to 18 mcommon palletizing opening size
SLSP30-1800Q8830 mm1800 mm12032 ms0.1 to 18 mfull body opening at 1.8 m
SLLP14-910P8814 mm910 mmnot published26.9 ms0.1 to 12 mEZ-SCREEN LS, 36 x 45 mm housing, IP65 and IP67
SLLP23-910P8823 mm910 mmnot published15.9 ms0.1 to 12 m23 mm hand detection at 12 m
F3SG-4SRA0320-1414 mm320 mm318 ms0.3 to 10 mOmron advanced, IP65, IP67 and IP67G
F3SG-4SRA0480-1414 mm480 mm4718 ms max0.3 to 10 msame body, taller field
F3SG-4SRA0640-1414 mm640 mm6318 ms max0.3 to 10 mcascadable with a second pair
F3SG-4SRA0800-1414 mm800 mm7918 ms max0.3 to 10 mmuting and blanking available on this family
F3SG-4SRA1200-1414 mm1200 mm11918 ms max0.3 to 10 mfull height finger protection

Resolution, Safety Distance and the Number Buyers Get Wrong

The safety distance is where a curtain is most often installed short. The formula is simple, but two of its terms are easy to take from the wrong place: the response time has to be the installed pair, and the penetration factor has to match the resolution that is actually enabled, including reduced resolution and blanking.

Resolution in usePenetration factor CEffect on the mounting distance
14 mm, reduced resolution off0 mmdistance is set by stopping time only
14 mm, reduced resolution on128 mmsame pair, but mounted 128 mm further back
30 mm128 mma hand curtain adds the same factor as reduced 14 mm
40 mm208 mmbody detection on a large opening
Blanking activerecalculate per beama blanked beam is no longer detected, so the opening behaves as a larger resolution

Key Features

Type 4 with two OSSD outputs – both outputs have to switch within the response time and are monitored against each other, so a single welded output cannot leave the guard in a safe looking state.

Resolution ladder from 14 to 40 mm – one family covers finger, hand and body detection, which lets a machine builder keep one spare pair and one mounting bracket set across a line.

Response time published per length – 9 ms on a 150 mm pair against 56 ms on a 1.8 m pair is a factor of six, and it goes straight into the safety distance, so the height cannot be increased without recalculating the mounting.

Range that survives a dirty shop – the 30 mm pair reaches 18 m and the 14 mm pair 6 m, which is enough margin to run at a shorter distance in a welding cell where the lenses need cleaning.

Diagnostics for alignment and faults – OSSD status, a fault output and an alignment indicator on the receiver shorten the time spent squaring a pair after a mechanical change.

Muting, blanking and cascading – the advanced Omron and LS families support muting for a conveyor opening and cascade connection for a corner, without a second safety relay for each pair.

Applications

Curtains are bought by the opening they guard and by what has to be kept out of it, so these three cases cover most of the requests we see.

Press and stamping guards – a 14 mm pair across the tool opening stops the ram before a finger can reach the die, and the short response time of a 600 mm pair keeps the safety distance small enough to load the part.

Robot cell and palletizing openings – a 30 mm pair at 1.2 to 1.8 m guards the opening of a cell where a person can walk in, with muting on the conveyor so a pallet can pass without stopping the robot.

Packaging and labelling lines – a 23 or 40 mm pair at 12 m covers a wide infeed without posts in the walkway, and the body detection resolution avoids stopping the line every time a case breaks a beam.

The guard is quoted with the control board behind it, so the SUPERB PCBA and the SUPERB PCB are checked on the same stop circuit and the OSSD pair lands on the safety relay terminals that the drawing names.

Sourcing and Cross-Reference

The two families on this page are not interchangeable at the connector level, so the first question is which receiver is already on the machine. Banner SLS and LS pairs use an M12 pigtail with 5 or 8 pins, and the pin count decides whether external device monitoring and a fault output are available. Omron F3SG-SR pairs use a root connector that is ordered as a separate line, which is a common reason a replacement arrives and cannot be plugged in.

A curtain is also a system, not a single part. The safety relay that the OSSDs feed, the brackets that hold the bars, the mirror that turns a corner and the test rod that the inspection procedure calls for are all separate order lines, and a quote that lists only the pair is short. Where a machine is being rebuilt, the old brackets rarely match the new housing profile, and the 36 x 45 mm LS body is slimmer than the older extruded profile it replaces.

For a line that is down, the practical substitute is the same resolution at the nearest available height, with the safety distance recalculated for the new response time. A taller pair is not automatically safe: it reacts more slowly and has to be mounted further from the hazard. See lead time and availability and shortage recovery for the options on a specific pair.

The SUPERB Assembly team keeps the two OSSD wires in separate terminals all the way to the relay, because a shared terminal defeats the cross monitoring inside the curtain.

Q: Can you supply the light curtain together with the safety relay, the brackets and the M12 cables as one matched set for a cell rebuild?

A: Yes. Send the opening size, the resolution the risk assessment asks for and the stop time of the machine, and the SUPERB Tech team returns the pair, the mounting distance and the relay that match.

Why Machine Builders Buy Light Curtains From SUPERB

  1. Resolution, height and response on one line: the three values that decide the safety distance are in the same row, so a substitute is checked without opening a catalogue.
  2. Pair and connector written out: the pin count and the connector type are part of the part number, which avoids a replacement that arrives with the wrong pigtail.
  3. Two families side by side: Banner and Omron pairs are compared on range, height and response, so a machine with either wiring can be matched.
  4. System parts kept visible: relays, brackets, mirrors and test rods are listed as separate items, because a curtain on its own does not guard anything.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Safety Relay Modules for Guard Monitoring, Door Interlock Switches for Safety Circuits, Emergency Stop Devices and Enabling Switches, Mechanical Limit Switches for Position Sensing, Inductive Proximity and Photoelectric Sensors.