Safety Light Curtains for Machine Guarding
Product Specifications
Product Overview
A safety light curtain is a pair of aluminium bars with no moving parts. The emitter fires a row of infrared beams at the receiver, the receiver checks that every beam arrives in sequence, and two solid state outputs stay energised while the screen is clear. Put a hand or a body into the screen and the outputs drop within the response time, the safety relay opens the stop circuit, and the machine stops. Because there is nothing to walk through and nothing to wear out, a curtain guards an opening that a gate would block and a mat would not cover.
Resolution is the number that decides what the curtain can see. A 14 mm curtain detects a finger and is used where the operator reaches into a hazard, a 23 or 30 mm curtain detects a hand and guards a cell opening, and a 40 mm curtain detects a body and is used where the risk is walking in. Resolution also enters the safety distance calculation. Under ISO 13855 the minimum distance is K multiplied by the total stopping time plus a penetration factor, and for resolutions up to 40 mm that factor is 8 x (resolution - 14), so a 14 mm curtain adds no distance while a 30 mm curtain adds 128 mm.
Range and response time both follow the beam count. A short pair has fewer beams, so it reacts faster and reaches less far; the Banner 14 mm pair reaches 6 m and the 30 mm pair reaches 18 m, while a 14 mm pair at 1.2 m height needs 40 ms and a 150 mm pair needs 11 ms. Mirrors and lens shields cut the range, about 8 percent per glass mirror and 10 percent per lens shield, and the mounting distance has to be calculated with the real response time of the pair that is installed, not the family headline.
Key Specifications
| Parameter | Value | Note |
|---|---|---|
| Safety category | Type 4 per IEC 61496-1 and IEC 61496-2 | PL e and SIL 3 on the Banner LS pair, SIL 3 CL3 |
| Resolution | 14 mm finger, 23 mm and 30 mm hand, 40 mm body | beam gap is 10 mm on the 14 mm and 25 mm Omron types |
| Protective height | 150 mm to 2.4 m on the Banner SLS, 160 mm to 2.0 m on the Omron 14 mm range | height steps of 150 mm on the Banner SLS |
| Number of beams | 10 to 240 on the Banner SLS, 15 to 199 on the Omron 14 mm range | beam count sets the response time |
| Operating range, 14 mm | 0.1 to 6 m on the Banner SLS, 0.3 to 10 m on the Omron SRA | 0.1 to 12 m on the Banner LS 14 mm pair |
| Operating range, 30 mm | 0.1 to 18 m | range falls with mirrors and lens shields |
| Response time | 9 ms at 150 mm, 23 ms at 600 mm, 40 ms at 1.2 m, 56 ms at 1.8 m | Banner SLS figures, ON to OFF |
| Response time, Omron 14 mm | 8 to 18 ms with optical synchronization | 10 to 21 ms with wired synchronization |
| Outputs | 2 x OSSD, 24 V DC, 500 mA each on the Banner LS | Omron protected output 300 mA, PNP or NPN selectable |
| Supply voltage | 24 V DC plus or minus 15 percent | Omron 19.2 to 28.8 V DC |
| Housing protection | IP65 and IP67 | IP67G on the Omron F3SG-SR |
| Effective aperture angle | plus or minus 2.5 degrees at 3 m | Type 4 requirement per IEC 61496-2 |
| Ambient temperature | -20 to +55 C on the Banner LS | -30 to +55 C on the Omron F3SG-SR |
| Light source | modulated infrared, 870 nm on the Omron part | immunity to daylight and to other curtains on the line |
| Connection | M12 5 pin or 8 pin pigtail on the Banner LS | Omron root connector ordered separately |
| Safety distance | S = K x T + 8 x (resolution - 14) | ISO 13855, T includes machine stop time and curtain response time |
Included Models and Order Codes
The table lists the pairs that cover the usual opening sizes rather than every length in the catalogue. On the Banner SLS the pair code carries the resolution and the defined area: SLSP14-600Q88 is a 14 mm pair with a 600 mm protected height and an 8 pin quick disconnect, and the number after the dash is the height in millimetres. The Omron code reads the same way: F3SG-4SRA0320-14 is a Type 4 advanced curtain with a 320 mm protective height and 14 mm detection. Where a height is not listed, the same family is available in 40 mm steps on the Omron side and 150 mm steps on the Banner side, and the beam count moves with the height.
| Part number | Resolution | Protective height | Beams | Response time | Range | Note |
|---|---|---|---|---|---|---|
| SLSP14-600Q88 | 14 mm | 600 mm | 80 | 23 ms | 0.1 to 6 m | finger detection, 8 pin quick disconnect pair |
| SLSP14-900Q88 | 14 mm | 900 mm | 120 | 32 ms | 0.1 to 6 m | taller opening on the same 6 m range |
| SLSP14-1200Q88 | 14 mm | 1200 mm | 160 | 40 ms | 0.1 to 6 m | the slowest 14 mm pair in the family |
| SLSP30-600Q88 | 30 mm | 600 mm | 40 | 15 ms | 0.1 to 18 m | hand detection, long range |
| SLSP30-900Q88 | 30 mm | 900 mm | 60 | 19 ms | 0.1 to 18 m | cell opening, 18 m reach |
| SLSP30-1200Q88 | 30 mm | 1200 mm | 80 | 23 ms | 0.1 to 18 m | common palletizing opening size |
| SLSP30-1800Q88 | 30 mm | 1800 mm | 120 | 32 ms | 0.1 to 18 m | full body opening at 1.8 m |
| SLLP14-910P88 | 14 mm | 910 mm | not published | 26.9 ms | 0.1 to 12 m | EZ-SCREEN LS, 36 x 45 mm housing, IP65 and IP67 |
| SLLP23-910P88 | 23 mm | 910 mm | not published | 15.9 ms | 0.1 to 12 m | 23 mm hand detection at 12 m |
| F3SG-4SRA0320-14 | 14 mm | 320 mm | 31 | 8 ms | 0.3 to 10 m | Omron advanced, IP65, IP67 and IP67G |
| F3SG-4SRA0480-14 | 14 mm | 480 mm | 47 | 18 ms max | 0.3 to 10 m | same body, taller field |
| F3SG-4SRA0640-14 | 14 mm | 640 mm | 63 | 18 ms max | 0.3 to 10 m | cascadable with a second pair |
| F3SG-4SRA0800-14 | 14 mm | 800 mm | 79 | 18 ms max | 0.3 to 10 m | muting and blanking available on this family |
| F3SG-4SRA1200-14 | 14 mm | 1200 mm | 119 | 18 ms max | 0.3 to 10 m | full height finger protection |
Resolution, Safety Distance and the Number Buyers Get Wrong
The safety distance is where a curtain is most often installed short. The formula is simple, but two of its terms are easy to take from the wrong place: the response time has to be the installed pair, and the penetration factor has to match the resolution that is actually enabled, including reduced resolution and blanking.
| Resolution in use | Penetration factor C | Effect on the mounting distance |
|---|---|---|
| 14 mm, reduced resolution off | 0 mm | distance is set by stopping time only |
| 14 mm, reduced resolution on | 128 mm | same pair, but mounted 128 mm further back |
| 30 mm | 128 mm | a hand curtain adds the same factor as reduced 14 mm |
| 40 mm | 208 mm | body detection on a large opening |
| Blanking active | recalculate per beam | a blanked beam is no longer detected, so the opening behaves as a larger resolution |
Key Features
Type 4 with two OSSD outputs – both outputs have to switch within the response time and are monitored against each other, so a single welded output cannot leave the guard in a safe looking state.
Resolution ladder from 14 to 40 mm – one family covers finger, hand and body detection, which lets a machine builder keep one spare pair and one mounting bracket set across a line.
Response time published per length – 9 ms on a 150 mm pair against 56 ms on a 1.8 m pair is a factor of six, and it goes straight into the safety distance, so the height cannot be increased without recalculating the mounting.
Range that survives a dirty shop – the 30 mm pair reaches 18 m and the 14 mm pair 6 m, which is enough margin to run at a shorter distance in a welding cell where the lenses need cleaning.
Diagnostics for alignment and faults – OSSD status, a fault output and an alignment indicator on the receiver shorten the time spent squaring a pair after a mechanical change.
Muting, blanking and cascading – the advanced Omron and LS families support muting for a conveyor opening and cascade connection for a corner, without a second safety relay for each pair.
Applications
Curtains are bought by the opening they guard and by what has to be kept out of it, so these three cases cover most of the requests we see.
Press and stamping guards – a 14 mm pair across the tool opening stops the ram before a finger can reach the die, and the short response time of a 600 mm pair keeps the safety distance small enough to load the part.
Robot cell and palletizing openings – a 30 mm pair at 1.2 to 1.8 m guards the opening of a cell where a person can walk in, with muting on the conveyor so a pallet can pass without stopping the robot.
Packaging and labelling lines – a 23 or 40 mm pair at 12 m covers a wide infeed without posts in the walkway, and the body detection resolution avoids stopping the line every time a case breaks a beam.
The guard is quoted with the control board behind it, so the SUPERB PCBA and the SUPERB PCB are checked on the same stop circuit and the OSSD pair lands on the safety relay terminals that the drawing names.
Sourcing and Cross-Reference
The two families on this page are not interchangeable at the connector level, so the first question is which receiver is already on the machine. Banner SLS and LS pairs use an M12 pigtail with 5 or 8 pins, and the pin count decides whether external device monitoring and a fault output are available. Omron F3SG-SR pairs use a root connector that is ordered as a separate line, which is a common reason a replacement arrives and cannot be plugged in.
A curtain is also a system, not a single part. The safety relay that the OSSDs feed, the brackets that hold the bars, the mirror that turns a corner and the test rod that the inspection procedure calls for are all separate order lines, and a quote that lists only the pair is short. Where a machine is being rebuilt, the old brackets rarely match the new housing profile, and the 36 x 45 mm LS body is slimmer than the older extruded profile it replaces.
For a line that is down, the practical substitute is the same resolution at the nearest available height, with the safety distance recalculated for the new response time. A taller pair is not automatically safe: it reacts more slowly and has to be mounted further from the hazard. See lead time and availability and shortage recovery for the options on a specific pair.
The SUPERB Assembly team keeps the two OSSD wires in separate terminals all the way to the relay, because a shared terminal defeats the cross monitoring inside the curtain.
Q: Can you supply the light curtain together with the safety relay, the brackets and the M12 cables as one matched set for a cell rebuild?
A: Yes. Send the opening size, the resolution the risk assessment asks for and the stop time of the machine, and the SUPERB Tech team returns the pair, the mounting distance and the relay that match.
Why Machine Builders Buy Light Curtains From SUPERB
- Resolution, height and response on one line: the three values that decide the safety distance are in the same row, so a substitute is checked without opening a catalogue.
- Pair and connector written out: the pin count and the connector type are part of the part number, which avoids a replacement that arrives with the wrong pigtail.
- Two families side by side: Banner and Omron pairs are compared on range, height and response, so a machine with either wiring can be matched.
- System parts kept visible: relays, brackets, mirrors and test rods are listed as separate items, because a curtain on its own does not guard anything.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Safety Relay Modules for Guard Monitoring, Door Interlock Switches for Safety Circuits, Emergency Stop Devices and Enabling Switches, Mechanical Limit Switches for Position Sensing, Inductive Proximity and Photoelectric Sensors.