Infrared Thermopile Temperature Sensors for Non Contact Measurement

A thermopile turns the infrared energy of a surface into a voltage, and the field of view decides how much of that surface is averaged. The digital parts carry a 17 bit converter, so the reading arrives over SMBus or I2C at 0.02 C resolution without an external amplifier. Fields of view run from 90 degrees for a close surface to 5 degrees for a target a metre away, and the spot size follows the half angle. Medical accuracy versions hold plus or minus 0.2 C around body temperature, which is a different part number, not a calibration step.
quote now

Product Specifications

Product Overview

An infrared thermometer does not touch the surface it measures, so everything between the sensor and the target matters: the emissivity of the surface, the gas in the path, the temperature of the sensor package itself and the size of the spot the optics project. A thermopile sensor answers only the last two of those well. It measures the temperature difference between its cold junction and the absorber, and it reports the result together with its own die temperature, which is why the digital parts give an ambient reading next to the object reading.

The field of view is the number that is most often misread. A 90 degree part sees a spot as wide as twice the distance, so at 100 mm it averages a 200 mm circle. A 5 degree part sees 8.7 mm at the same distance. Between those two extremes the same target can read several degrees apart, because a wide part averages the background into the reading and a narrow part misses the target if it is aimed badly. The table below carries the spot size at two working distances for each field of view, calculated from the half angle, so the aim can be checked before the part is ordered.

There are two electrical families here as well. The analogue thermopile, represented by the ZTP-148SR in a TO-46 can, gives a small voltage and an NTC resistance for the cold junction, and the host has to run both through its own converter and its own polynomial. The digital parts, MLX90614 and MLX90632, put the amplifier, the 17 bit converter and the calibration in the same package, and deliver a finished temperature over a two wire bus. The analogue part is still the right choice where the host already has a low noise converter and a housing that cannot take a digital part, and it is the cheaper route at high volume.

Medical accuracy is a separate ordering option and not a screening step. The MLX90614 versions marked with a D hold plus or minus 0.2 C between 16 and 40 C ambient with a 22 to 40 C target, and they comply with the ASTM E1965 section that covers intermittent patient temperature. A standard part can be calibrated to read a water bath well, and it will still drift more than a medical part over the ambient range a clinic sees, because the drift is compensated inside the medical version rather than in the host.

Key Specifications

ParameterValueNote
Sensor typethermopile with integrated or external cold junctiondigital parts carry amplifier, 17 bit converter and calibration
Object temperature range-70 to 380 C on MLX90614, -20 to 200 C on MLX90632, -20 to 100 C on ZTP-148SRthe medical MLX90632 stops at 100 C
Ambient temperature range-40 to 85 C on MLX90614, -20 to 85 C on MLX90632, -20 to 100 C on ZTP-148SRthe reading is compensated across this range
Accuracy, standardplus or minus 0.5 C between 0 and 50 C ambient and object on MLX90614valid only with the object filling the field of view
Accuracy, medicalplus or minus 0.2 C with ambient 16 to 40 C and object 22 to 40 Cmedical accuracy is only available on the D versions
Resolution0.02 C over SMBus, 0.01 C in the internal register, 0.14 C on 10 bit PWMMLX90632 delivers 0.02 C over I2C
Supply voltage4.5 to 5.5 V on A versions, 2.6 to 3.6 V on B and D versionsMLX90632 runs 3.0 to 3.6 V
Supply currentunder 2 mA active, under 6 uA in sleep on MLX90614MLX90632 under 1.4 mA active, under 2.5 uA in sleep
InterfaceSMBus or PWM on MLX90614, I2C on MLX90632 and the arraysPWM pin can also work as a thermal relay output
Field of view90, 70, 35, 15, 12, 10, 5 degrees on MLX90614, 50 degrees on MLX90632arrays cover 110 by 75 and 55 by 35 degrees
Emissivitycalibrated at 1.0 at the maker, adjustable 0.1 to 1.0 in EEPROMno black body recalibration needed for a different emissivity
Optical filterlong wave pass 5.5 to 14 um on lens versionsthe 12 and 5 degree parts use an uncoated germanium lens
PackageTO-39 can 9.1 mm diameter, 4.1 to 20.2 mm highMLX90632 is a 3 x 3 x 1 mm QFN, ZTP-148SR is TO-46
Thermopile data, ZTP-148SRinternal resistance 85 kΩ, responsivity 61 V/W, time constant 32 msNTC 100 kΩ at 25 C with beta 3960
Field of view, ZTP-148SR85 degrees typical at 50 percent of maximum outputsingle element with a flat infrared filter

Included Models and Order Codes

The MLX90614 ordering code reads in three blocks: the zone count, the field of view and the supply. AAA is a single zone 90 degree 5 V part, BAA is the same optic on a 3 V supply, ACC is the 35 degree gradient compensated version, BCI is the 5 degree part on 3 V, and the D versions are the medical accuracy parts in the same optics. That is why a 90 degree medical part and a 90 degree standard part look identical on a drawing and are not interchangeable in a fever screening build. MLX90632SLD-BCB-000 is the small QFN part with a 50 degree field and a 3 x 3 mm footprint, and its DCB variant is the medical one. MLX90640 and MLX90641 are thermopile arrays rather than single pixels: 32 by 24 and 16 by 12 elements, both over I2C, for a thermal image instead of an average. The ZTP-148SR and ZTP-148SRC1 are the analogue route: a TO-46 can with an 85 degree field, a 100 kΩ NTC for the cold junction and a responsivity of 61 V/W for the SR part.

Part numberField of viewSupplyOutputPackageNote
MLX90614ESF-AAA-00090 degrees4.5 to 5.5 VSMBus or PWMTO-39, 4.1 mm highsingle zone, standard accuracy, widest field
MLX90614ESF-BAA-00090 degrees2.6 to 3.6 VSMBus or PWMTO-39, 4.1 mm highsingle zone, standard accuracy, battery supply
MLX90614ESF-ACC-00035 degrees4.5 to 5.5 VSMBus or PWMTO-39, 8.1 mm highgradient compensated, the usual choice for a small target
MLX90614ESF-BCI-0005 degrees2.6 to 3.6 VSMBus or PWMTO-39, 20.2 mm highnarrowest optic, target about 1 m away
MLX90614ESF-DAA-00090 degrees2.6 to 3.6 VSMBus or PWMTO-39, 4.1 mm highmedical accuracy, wide field
MLX90614ESF-DCC-00035 degrees2.6 to 3.6 VSMBus or PWMTO-39, 8.1 mm highmedical accuracy, gradient compensated
MLX90614ESF-DCI-0005 degrees2.6 to 3.6 VSMBus or PWMTO-39, 20.2 mm highmedical accuracy, long distance screening
MLX90632SLD-BCB-00050 degrees3.0 to 3.6 VI2CQFN 3 x 3 x 1 mmsmallest footprint, object range to 200 C
MLX90632SLD-DCB-00050 degrees3.0 to 3.6 VI2CQFN 3 x 3 x 1 mmmedical accuracy in the same footprint, object range to 100 C
MLX90640ESF-BAA-000110 by 75 degrees2.9 to 3.6 VI2CTO-39, 5.7 mm high32 by 24 element array, thermal image output
MLX90641ESF-BCA-000110 by 75 degrees3.0 to 3.6 VI2CTO-39, 5.7 mm high16 by 12 element array, lower cost than the 32 by 24
ZTP-148SR85 degreesnoneanalogue mV plus NTCTO-46responsivity 61 V/W, thermistor 100 kΩ at 25 C
ZTP-148SRC185 degreesnoneanalogue mV plus NTCTO-46active area 0.7 by 0.7 mm, same NTC and time constant

Spot Size at Working Distance

The spot diameter is twice the distance multiplied by the tangent of half the field of view. The values below are calculated from that relation and are the ones to compare against the target size before a part is chosen, because a spot larger than the target averages the background into the reading.

Field of viewSpot at 30 mmSpot at 100 mmSpot at 300 mmTypical use
90 degrees60 mm200 mm600 mmsurface temperature on a board or a plate held close to the sensor
70 degrees42 mm140 mm420 mmdual zone part looking at a hand or a grille
50 degrees28 mm93 mm280 mmMLX90632 on a small board with a short working distance
35 degrees19 mm63 mm189 mmear or forehead thermometry at a fixed jig distance
12 degrees6.3 mm21 mm63 mmsmall part on a moving line
10 degrees5.3 mm17.5 mm53 mmnarrow target with a fixed mount
5 degrees2.6 mm8.7 mm26 mmscreening at about one metre, single person target

Key Features

Finished digital reading – the 17 bit converter and the calibration sit inside the can, so the host reads a temperature over SMBus or I2C and does not build an amplifier chain.

Field of view on the row – 90, 35, 12, 10 and 5 degree optics are listed with the spot size they produce, which is the number that decides whether the reading is the target or the background.

Medical accuracy as a part number – the D versions hold plus or minus 0.2 C around body temperature and follow ASTM E1965, so a screening build does not rely on a calibration step in the host.

Gradient compensation – the C versions measure the thermal gradient across the package and correct for it, which is what keeps a 35 degree part stable when the electronics behind it warm up.

Adjustable emissivity – the maker calibration is at emissivity 1.0 and the value can be set in EEPROM from 0.1 to 1.0 without a black body source.

Analogue route still available – ZTP-148SR gives a millivolt output and a 100 kΩ NTC, which suits a host that already has a low noise converter and no room for a digital part.

Array options – MLX90640 and MLX90641 return 32 by 24 or 16 by 12 pixels over I2C where a single average is not enough to find a hot spot.

Low sleep current – under 6 uA in sleep on the TO-39 parts and under 2.5 uA on the QFN, which matters for a handheld thermometer that sits idle between patients.

Applications

Three measurement jobs where the field of view and the accuracy class, rather than the interface, decide which part number is right.

Body temperature screening – a 5 degree medical part at about one metre covers a face without averaging the wall behind it, and the 0.2 C accuracy holds across a clinic ambience.

Surface temperature on a moving part – a 35 degree gradient compensated part on a bracket reads a motor housing or a bearing cap, where the package itself is warmed by the machine.

Hot spot search on a board – a 32 by 24 array returns a small thermal image over I2C, which finds a single warm component that a single pixel part would average away.

A handheld thermometer is a small board plus a housing, so the SUPERB PCBA and the SUPERB PCB are reviewed with the optic in place and the sensor kept away from the regulator that warms the package.

Sourcing and Cross-Reference

The first question on a replacement is the field of view, then the accuracy class, then the supply. A 90 degree part and a 35 degree part of the same family give different readings on the same target, so a build that was calibrated around one will not accept the other without a new jig. The second question is whether the original was a medical version, because the D parts are a different order code and the firmware compensation written for a standard part will not be right for a medical one.

The third question is the package and the height. The TO-39 parts run from 4.1 mm to 20.2 mm depending on the optic, and a 5 degree part is the tallest because the germanium lens sits in front of the die. A housing cut for a 35 degree part will not close over a 5 degree part, and the lens must not be pressed or cleaned with a solvent.

Where the original code is gone, the route is the same optic in the current accuracy class, or the QFN part where the board has room for a 3 mm package and the target is within 200 C. See lead time and availability for a specific code and obsolete part cross reference where the instrument carries an older marking.

The SUPERB Assembly team fits the TO-39 can after reflow with a socket or a hand solder at the lens end, because the germanium window on the narrow parts cannot take a wash or a bake.

Q: Can you confirm the field of view and whether the part is the medical accuracy version, because our screening jig was set up around the original optic?

A: Yes. Send the target size, the working distance, the accuracy class and the supply, and the SUPERB Tech team returns the field of view and the order code that fit.

Why Instrument Builders Source Thermopile Sensors Through SUPERB

  1. Optic and spot size together: each row gives the field of view and the spot it produces, so a target smaller than the spot is caught before the build starts.
  2. Accuracy class separated: standard and medical versions are listed as different codes, which keeps a screening instrument on the part its validation was written around.
  3. Package height listed: the height of each TO-39 variant is on the row, because the optic that gives a narrow field also makes the part taller.
  4. Analogue and digital on one page: the ZTP analogue part sits beside the digital family, so a host with an existing converter is not pushed onto a bus it does not have.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Thermocouple and RTD Front Ends, Temperature and Humidity Sensors for Environmental Monitoring, Gas Sensors for Air Quality and Leak Detection, Ambient Light and Proximity Sensors, Differential Pressure Sensors for Ventilators, Component Lead Time Solutions.