Optical Filter Mounts and Lens Holders Mounts that hold a lens where the beam expects it, and filter holders that let it be swapped. Fixed holders for 12.7, 25.4 and 50.8 mm optics with SM05, SM1 and SM2 threads. Kinematic and rotation mounts for alignment, drop in holders for quick filter changes.
Integrating Spheres and Diffuse Reflectance Standards Spheres that collect every reflected angle, and the white tiles that calibrate them. PTFE and Spectralon spheres from 30 to 200 mm, three or four ports. Calibrated standards from 2 to 99 percent, data every 50 nm from 250 to 2500 nm.
HPLC Columns for Reversed Phase Method Development Columns chosen by the method pH first. C18 and C8 chemistries, 4.6 mm and 2.1 mm bore. 5 and 3.5 um particles, 80 and 130 A pores, L1 classification.
Beam Dumps and Baffles for Stray Light Control Where the beam ends, on purpose. Traps and blocks from 200 nm to 12 um, 5 W to 500 W CW. Graphite, steel and ceramic absorbers, cage or post mounted.
Fiber Bundles and Light Guides for Spectrometers Bundles that match a spectrometer slit, not just a single fiber. Round to linear, bifurcated Y and fan out formats, 50 to 600 um cores. High OH, low OH and solarization resistant fibers, SMA 905 on both ends.
Lamp Reflectors and Ellipsoidal Condensers Ellipsoidal reflectors and condenser assemblies for lamp housings. Rhodium on nickel ellipsoids with both focal distances given. UV fused silica and Pyrex condensers, IR versions in germanium and ZnSe.
Autosampler Vials and Septa for HPLC 2 mL autosampler vials and closures for LC and GC trays. Screw neck 9 mm and crimp neck 11 mm, clear and amber, certified lots. PTFE silicone, sandwich and BTO septa, quoted as matched sets.
Neutral Density Filters and Photometric Reference Standards Neutral density filters and certified references for photometers. Absorptive ND filters in optical densities from 1.0 to 4.0 on 25 mm mounts. Schott NG glass references certified at 440, 465, 546.1, 590 and 635 nm. Holmium and didymium filters for wavelength checks, with NIST traceability.
Column Ovens and Heater Blocks for HPLC Compartments Column ovens and heater blocks that hold an HPLC column at temperature. Peltier ovens from 4.0 C to 70.0 C, heating only ovens from 20.0 C to 90.0 C. Aluminium block heaters to 150 C for columns up to 50 cm long. Stability of 0.1 C to 0.2 C, PID control and over temperature protection.
Optical Windows and Sapphire Discs for Detector Ports Windows and sapphire discs that seal a detector or sample port. UV fused silica from 185 nm, N-BK7 for visible work and sapphire for harsh ports. Thickness options from 1.0 mm to 12.0 mm in four AR coating bands. Flat, parallel and cleanable, with tolerances stated per size.
Tube Fittings and Ferrules for Reagent Lines Flangeless fittings and ferrules for analyser and HPLC reagent lines. 1/4-28 flat bottom, 10-32 coned and M6 ports for 1/16 and 1/8 inch tubing. ETFE ferrules to 2000 psi, PEEK and stainless two piece sets to 9000 psi. Nuts and ferrules listed separately so a single worn part can be replaced.
Lenses and Mirrors for Optical Benches Plano convex lenses and mirrors for photometric and analyser benches. N-BK7 lenses with three AR coating ranges from 350 nm to 3.0 um. Protected silver mirrors at 97.5% average reflectance from 450 nm to 2 um. Concave mirrors for focusing and relay paths, 1 inch body, 100 mm focal length.
Fiber Collimators and Patch Cords for Photometric Probes Collimating lenses and patch cords for photometric probes and dip cells. Lens options from f/2 at 10 mm focal length up to f/4 at 100 mm for long throw. Fixed focus FC/APC collimators at 543 nm and 1550 nm in a 12 mm body. Step index cords from 105 um to 600 um core in high OH and low OH glass.
Dichroic Filters and Beam Splitters for Photometric Channels Dichroic mirrors and beamsplitters for 45 degree photometric channels. Cut on wavelengths from 505 nm to 900 nm in 1 inch and 25 x 36 mm sizes. Plate splitters in five ratios and non polarizing cubes from 10 mm to 1 inch. Obsolete dichroics sourced on a last time buy basis against the original number.
Inline Filters and Frits for Reagent Lines A reagent line fails quietly. The pump seal wears, the injection valve rotor sheds a few particles, a buffer precipitates at the first cold spot, and the damage shows up as a rising back pressure or a split peak rather than as a leak. The filters below cover the three places that matter: an inlet cup in the reservoir, an inline body between the pump and the valve, and a precolumn body just ahead of the column. Pore size runs from 0.2 to 20 micron, swept volume from 10 nL to 103 microlitre, and the wetted path is 316 stainless steel, PEEK or titanium, so the same family covers an HPLC line and a clinical reagent path. Each line gives the pore size, the swept volume and the pressure rating together, because a filter chosen on pore size alone can add more dispersion than the column can absorb.
Bandpass and Interference Filters for Photometric Channels A bandpass filter is specified by two numbers that are often confused, the guaranteed bandwidth that carries the transmission and the full width at half maximum. The parts below run from 340 to 1055 nm with guaranteed bandwidths from 6 to 90 nm, and every one is a hard coated single substrate filter in a 25 mm ring. Each entry gives centre wavelength, bandwidth, average transmission across the passband and the blocking levels on either side. The passband figure is quoted as an average over a stated band, because a peak transmission number tells nothing about what the channel sees at its edges.
Quartz Flow Cells and Cuvettes for Photometric Instruments In a flow cell the optical path and the volume pull against each other, and the method decides which one gives way. The parts below cover all quartz flow cells from 0.1 to 50 mm path with volumes from 6 to 3200 microlitres, plus cuvettes for batch work with a held path length tolerance. Each entry gives path length, centre height, outside dimensions, aperture and volume, so the cell is matched to the light beam and to the tubing that feeds it. Window material is listed with the wavelength band it transmits, because a quartz cell and an optical glass cell are not interchangeable at 340 nm.
Inline Fluid Heaters and Peltier Chillers for Analysers Heating a flowing liquid is a race between the power going in and the heat the tube takes out, and the number that settles it is watt density, not wattage. The parts below cover layered inline heaters from 250 W to 4 kW with water side densities up to 70 W per square centimetre, and thermoelectric chillers that hold a closed loop between minus 12 and plus 40 C. Each entry gives voltage, wattage, heated length, the number of zones and the density at that length, so a heater is chosen from the flow and the temperature rise rather than from the label. Chillers are listed with cooling capacity, control range and the interface, because a chiller that cannot be read by the instrument controller is a chiller that runs open loop.
Fluid Check Valves and Shuttle Valves for Reagent and Pneumatic Lines A check valve in a reagent line is a pressure gate, and the figure that decides whether the line works is the cracking pressure, not the body size. The parts below cover diaphragm, umbrella, duckbill and spring check valves from 0.11 psi to 10 psi cracking, plus shuttle valves for choosing between two pneumatic sources. Cracking pressure is quoted with the spring tolerance, because a 3 psi nominal spring is allowed to open anywhere from 2.1 to 3.9 psi. Every entry lists body material, seal material, connection and maximum working pressure, so the valve is matched to the reagent before it is matched to the tube.
Medical Isolation Transformers for Diagnostic and Laboratory Equipment A medical isolation transformer separates the mains from the instrument, and the figure that proves it did its job is the leakage current, not the isolation voltage. The parts below are toroidal transformers from 50 VA to 3,000 VA with dual primary and dual secondary windings, 5 kVrms isolation and leakage under 100 microampere. Each rating is listed with its outline, its height and its weight, because a 3,000 VA toroid has to fit a chassis before it can be ordered. The leakage limits from IEC 60601-1 are listed next to the parts, because the transformer is only one contributor to the figure the finished instrument has to meet.
Quick Disconnect Couplings and Luer Fittings for Reagent Lines A coupling on a reagent line is opened every time a bottle is changed, and what it does at that moment decides whether the instrument needs a wipe down. The parts below split into valved quick disconnects that shut both halves on separation, and luer fittings that join small bore tubing inside a manifold. Flow coefficients run from 0.6 on a non spill coupling to 1.4 on a quarter inch valved coupling, and the spill volume per disconnect is quoted on the non spill version. Each entry lists pressure, temperature, wetted material and tubing size, because a coupling is chosen by the tube it has to fit before it is chosen by the flow.
Split Core Current Transformers for Retrofit Metering A split core transformer clamps around a cable that is already installed, so a metering point is added without cutting the conductor. The family runs from 200 A through a 0.75 inch opening to 3000 A through a 3 inch opening. Output is 0.333 V AC at rated current, which is a voltage signal that does not need a shorting switch. Accuracy is plus or minus 1 percent from 10 to 130 percent of rated current, class 1.0 to IEC 61869-2 on the larger frames.
CT Test Terminal Blocks and Shorting Links A current transformer secondary must never be opened under load, so the test point has to short before it separates. Test disconnect blocks do that inside one 8.2 mm body, with a 4 mm socket on each side of the break. Rated 41 A on a 6 mm2 conductor and 57 A on 10 mm2, with 0.72 to 1.2 kA short time current. Shorting links and switching jumpers complete a three phase set without handling the CT wiring.
Earth Fault Relays for Resistance Grounded Systems A resistance grounded system limits earth fault current, so the relay has to work with a few amps instead of a few thousand. Trip levels run from 0.5 to 4 A on the compact relays, and 2 to 100 percent of the CT primary on the monitoring types. Trip time is adjustable from 0.1 to 10 seconds, with harmonic filtering so a drive does not trip the feeder. The same unit watches the neutral grounding resistor, because an open resistor leaves the protection blind.
Voltage Transformers for Panel Metering and Protection A voltage transformer brings 415 V down to 110 V so a meter or a relay can read the line without touching it. Three phase units run 25 to 200 VA at class 0.5 or class 1, with a 1.9 voltage factor for eight hours. Residual winding types give 110/110 V for broken delta earth fault detection on the same footprint. Single pole units go up to 36 kV system voltage where the metering point sits on a medium voltage board.
Insulation Fault Locators for IT Systems An insulation fault locator finds which outgoing circuit in an unearthed system has the fault, not only that a fault exists. Each unit reads twelve measuring current transformers, and fifty units on one bus cover 600 circuits. Sensitivity is 2 to 10 mA for main circuits and 0.2 to 1 mA for control circuits and medical locations. The locating current is injected by the insulation monitor or by a separate injector, so the locator works with the monitoring system already in the panel.
Protection Current Transformers for Overcurrent Relays A protection transformer has to hold its ratio while a fault current runs, not only at rated current. This range covers 100/5 to 5000/5 in class 5P10 and 5P20, with burdens from 2.5 to 35 VA. The accuracy limit factor is quoted at rated burden, so the actual burden decides the real factor. Windows run from 40 to 180 mm, which covers cable primaries and busbar primaries in low voltage panels.
Rogowski Coil Current Sensors for Retrofit Metering A Rogowski coil has no iron core, so it reads a busbar from a few hundred amps to 15,000 A without saturation. The coil opens at the connector and closes around a cable or bar that cannot be disconnected. Output is 0.070 V per 1,000 A at 60 Hz, and a meter with a Rogowski input or an external integrator scales it. Linearity is 0.5 % from 100 A to 15,000 A, and phase displacement stays under 0.5 degrees for power readings.
Neutral Grounding Resistors for Resistance Grounded Systems A neutral grounding resistor limits the current that flows when one phase touches earth, so the fault is detected without destroying the transformer. The range covers 240 V to 72 kV systems, with current ratings up to 5000 A and duty from ten seconds to continuous. Time rating and temperature rise are the two numbers that size the resistor, and both come from IEEE 32. High resistance grounding on a 600 V system holds the fault current under 25 A and lets the plant run until the fault is located.
Metering Current Transformers for Panel and Switchgear A metering transformer steps the feeder current down to 5 A so a meter or a relay can read it without breaking the circuit. The range covers 100, 150 and 200 A primaries with a 21 mm cable window and a 6 kA thermal rating. Accuracy is class 0.5 at 2 VA, class 1 at 2.5 VA and class 3 at 3.5 VA, so the burden decides the class that is reached. The transformer class sets the accuracy of the whole metering point, whatever the meter is rated.
Multifunction Power Meters and Power Quality Analyzers A multifunction meter replaces the row of single function instruments on a panel door with one unit that measures voltage, current, power, power factor and energy. Accuracy runs from class 0.5S for sub metering to class 0.2S for billing and utility reporting. Harmonic analysis reaches the 31st order on the metering types and the 63rd on the billing type. The communication port, the current transformer and the tariff structure decide the model, not the display size.
Static VAR Generators for Dynamic Reactive Compensation A static VAR generator supplies or absorbs reactive current in steps smaller than a kvar, so the compensation follows the load instead of jumping between stages. Units run from 30 to 200 kvar at 400 V, with 480 V and 690 V families on the same frames. Full output is reached within 15 ms, and the target power factor runs from minus one to plus one. The unit is a converter, so it needs a current transformer, an air path and a short circuit protection, and all three decide whether it works.
Capacitor Discharge Reactors and Discharge Modules A discharge reactor brings a capacitor step below 50 V in seconds, so the step can be switched again inside the controller delay. Units cover 230 to 690 V networks and steps from 5 to 100 kvar, in a housing that clips onto a 35 mm rail. Loss is under 1.6 W against the several watts a bank of fixed resistors leaves in the enclosure. One unit per step is the usual arrangement, and the discharge time has to match the controller delay.
Active Harmonic Filters for Low Voltage Networks An active filter measures the harmonic current of the load and injects the same waveform in opposition, so the network sees a clean current. Units run from 40 to 300 A at 380 to 690 V, with harmonic cancellation to the 51st order and a two cycle correction time. The same unit corrects power factor in a quarter cycle and balances current between phases. Sizing follows the harmonic current of the load, not the load current, and the difference is where most oversized quotes come from.
Reactive Power Controllers for Automatic Capacitor Banks The controller reads voltage and current, works out the reactive power and closes the step that brings the power factor back to target. Outputs run from 3 to 12 relay steps, with a 1 A or 5 A current input and a C/k setting that follows the smallest step. Alarm contacts cover overvoltage, undervoltage, over temperature and a target that is not reached. The switching sequence is what separates a good bank from a chattering one, and it is set per installation.
Thyristor Switches for Capacitor Bank Switching A thyristor switch closes a capacitor step at the zero crossing of the current, so the step draws no inrush peak. Modules run from 10 to 100 kvar at 380 to 440 V, with 480 V and 690 V versions for other networks. Reaction time is 5 ms, and every module monitors supply voltage, phase sequence, capacitor output and temperature. Fuse, series reactor and ventilation clearance travel with the module, because those three decide how long the step lives.
Detuned Reactors and Harmonic Filters for Capacitor Banks A reactor in series with each capacitor step moves the resonant frequency below the lowest harmonic in the network, which stops the bank from amplifying it. Three detuning factors cover the common cases: 5.7 percent at 210 Hz, 7 percent at 189 Hz and 14 percent at 134 Hz. Each step is quoted with its inductance, fundamental current, RMS current and losses, because those four set the cable and the fan. The capacitor voltage rating changes with the factor, and that pairing is the point most often missed.
Interface and Coupling Relays for DIN Rail A 6.2 mm housing with one changeover contact at 6 A, so a PLC output drives a valve, a lamp or a small contactor without carrying the load itself. Coils run from 12 V DC to 230 V AC, with LED indication and a freewheel diode or bridge rectifier built into the base. The relay plugs into the base, so a failed part is changed without touching the field wiring. Gold contact versions hold 1 mA signals, which is what a dry contact or a multiplexer input needs.
Capacitor Switching Contactors for Power Factor Correction Contactors built for capacitor steps, where the closing peak reaches 100 times the running current. Standard AC-6b devices cover peaks up to that limit, and damping resistor versions take an unlimited peak. Ratings run from 12.5 to 100 kvar at 400 V, in 24 V DC and 220 to 230 V AC coils. Fuse, discharge and ambient derating sit next to each rating, because those three decide how long the contactor lasts.
EMC Cable Glands and Shield Clamps for Shielded Cables Brass cable glands that bond a cable shield to the enclosure at the entry, with a brush that touches the braid in one step. Contact resistance is 10 mOhm or less over a 360 degree contact area, which is what a drive cable needs at both ends. Sizes run M16 to M110 with IP68 to 10 bar and IP69 on the metric range, with strain relief to category A. Rail mounted shield clamps from 3 mm to 22 mm are listed for cables that are bonded inside the cabinet.