Contact Us
  • Home
  • COMPONENTS
  • Level Sensors and Float Switches for Tanks and Sumps

Level Sensors and Float Switches for Tanks and Sumps

A float switch is a reed contact inside a stem and a magnet inside a float, so it needs no supply and no signal conditioning. The 25 VA family switches 0.6 A at 240 V AC, and the 100 VA family 1 A at 300 V AC or DC. Bodies come in nylon, polypropylene, PPS and PVDF, with M12 by 1.75 or 1/8 NPT mounting. External fitting versions mount through a tank wall from outside, where the inside is not accessible.
quote now

Product Specifications

Product Overview

A float switch is the simplest level device there is: a magnet in the float closes a reed contact in the stem, and the contact is the output. There is no supply to bring to the tank, no drift to calibrate out and no software. The trade is that the contact is a small sealed switch, so the load it can break is limited and the load type matters. A 25 VA contact that switches a small solenoid directly will weld within a few thousand operations, while the same contact driving a relay coil lasts for years.

The second decision is mounting. An internal fitting switch goes through a hole in the top or the bottom of the tank and needs access to the inside for the nut. An external fitting switch goes through the wall from outside with a compression seal, which is the only option where the tank is welded shut or holds something that cannot be opened. The thread and the hole size are the difference: M12 by 1.75 on the compact bodies, M16 by 2 on the compression seal bodies, and 1/8 NPT where the tank is threaded to an American drawing.

The third decision is the material, and it follows the liquid. Nylon covers water and most aqueous solutions up to 75 C. Polypropylene goes to 100 C and is the general chemical body. PPS goes to 105 C and holds its dimensions better in hot water. PVDF is the body for aggressive chemicals and for lines that are cleaned with solvents. The float specific gravity matters as much: a float sized for water will not switch in a liquid with a specific gravity near 0.8, and the level at which it closes moves with the liquid.

Key Specifications

ParameterValueNote
Typefloat switch, reed contact inside the stem, magnet in the floatno supply, the contact is the output
Contact formnormally open or normally closedreversed by inverting the float on the stem
Switching power25 VA on the Y code, 100 VA on the H coderesistive load only
Switching voltage, 25 VA240 V AC maximum, 120 V DC maximum0.6 A maximum
Switching voltage, 100 VA300 V AC maximum, 300 V DC maximum1 A maximum
Body materialsnylon, polypropylene, PPS, PVDFchosen on liquid and temperature
Temperature rangeminus 20 to plus 75 C in nylon, minus 20 to plus 100 C in polypropylene, minus 10 to plus 105 C in PPShigher figures need the ETFE cable option
Mounting, internal fittingM12 by 1.75, or 1/8 NPTnut and gasket inside the tank
Mounting, external fittingM16 by 2 compression seal through a 23 mm holeno access to the inside needed
Float diameter27 mm on the compact internal bodies30 mm maximum body height
Lead length1 m PVC as standard, ETFE for high temperature2 core 7 by 0.2 mm
ApprovalsWRAS on the potable water versions, UL recognised file E171218per variant
Specific gravityfloats sized for water at 1.0a lower specific gravity liquid needs a different float
Mounting orientationvertical, from the top or the bottom of the tankside mount bodies are a separate family

Included Models and Order Codes

The code splits into two groups: internal fitting bodies that go through a hole in the tank, and external fitting bodies that clamp through the wall. RSF50 is the compact internal family, with a 27 mm float, M12 by 1.75 or 1/8 NPT thread, and a single switch point. RSF53 is the nylon body for water up to 75 C, RSF58 the polypropylene body rated to 100 C, and RSF56 the PPS body rated to 105 C. The H in the code is the 100 VA contact and the Y is the 25 VA contact, so RSF53H100RC and RSF53Y100RC are the same body with different contact ratings. RSF70 is the external fitting family: it goes through a 23 mm hole and seals with an M16 by 2 compression gland, which is the one for a tank that cannot be opened. RSF100 is the miniature external body, with a smaller float and the same compression seal, for a shallow tank or a sump.

Order codeBody materialContact ratingMountingTemperature
RSF53H100RCnylon100 VA, 1 A at 300 V AC or DCM12 by 1.75 internalminus 20 to plus 75 C
RSF53Y100RCnylon25 VA, 0.6 A at 240 V ACM12 by 1.75 internalminus 20 to plus 75 C
RSF53H100R1/8nylon100 VA1/8 NPT internalminus 20 to plus 75 C
RSF58H100RCpolypropylene, UL recognised100 VAM12 by 1.75 internalminus 20 to plus 100 C
RSF56H100RCPPS100 VAM12 by 1.75 internalminus 10 to plus 105 C
RSF56Y050TBPPS with ETFE cable25 VAM12 by 1.75 internalminus 10 to plus 120 C
RSF73H100nylon, external fitting100 VAM16 by 2 compression sealper maker sheet
RSF107H100GNPVDF, external fitting100 VAM16 by 2 compression sealper maker sheet

Contact Rating and Load Type

The two contact ratings are not interchangeable, and the difference is not only the current. The 25 VA contact switches 0.6 A at 240 V AC and 120 V DC, and the 100 VA contact switches 1 A at 300 V AC and DC. Both figures are for a resistive load, and a solenoid coil or a lamp is not resistive: the inrush of a small solenoid can be ten times its holding current, which is why the usual arrangement is a float switch driving a relay coil and the relay driving the load. The table puts the two ratings side by side so the load can be checked against the contact that is actually being ordered.

RatingMaximum AC voltageMaximum DC voltageMaximum currentTypical use
25 VA contact240 V AC120 V DC0.6 Arelay coil, PLC input, alarm lamp
100 VA contact300 V AC300 V DC1 Asmall pump contactor coil, heater relay
25 VA with solenoid loadnot recommendednot recommendedinrush exceeds the contactadd an interposing relay
100 VA with solenoid loadcheck inrushcheck inrushinrush exceeds the contactadd an interposing relay

Key Features

No supply at the tank – the reed contact is the output, so the only wiring to the tank is the two core lead and there is nothing to power or to configure.

Two contact ratings in one body – 25 VA and 100 VA are the same stem and float, so the rating is a code letter rather than a different device.

Four body materials – nylon, polypropylene, PPS and PVDF cover water, hot water, general chemicals and aggressive solvents with the same switch point.

Internal or external fitting – the compact bodies go through a hole in the tank and the external bodies clamp through the wall, which is the only option where the tank cannot be opened.

Action reversed by inverting the float – the normally open contact becomes normally closed by removing the float and refitting it upside down, which removes a separate part number.

Potable water versions – the WRAS approved variants are marked, so a drinking water or a food line is not built from a general purpose body.

Thread options for both drawing styles – M12 by 1.75 and 1/8 NPT on the same body, and M16 by 2 on the compression seal bodies.

Temperature with cable option – the PPS body reaches 105 C and 120 C with the ETFE cable, which is the detail that fails first on a hot sump.

Applications

Three tank arrangements where the mounting style decides the part before the material does.

Coolant and lubricant sumps – an internal fitting nylon body on the tank top gives a low level alarm, and the 25 VA contact drives a PLC input without an interposing relay.

Chemical dosing tanks – a polypropylene or PVDF body with an external compression seal goes through the wall, so the tank is not opened for installation.

Hot water and cleaning lines – a PPS body with the ETFE cable holds 105 to 120 C, which is where a nylon body would soften and lose its switch point.

A tank sensor usually terminates on a small I/O board, so the SUPERB PCBA and the SUPERB PCB are checked against the same terminal list and the lead entry is reviewed once for both.

Sourcing and Cross-Reference

The first question is the mounting, because it fixes the hole in the tank. An internal fitting body needs a nut and a gasket inside, and an external fitting body needs a 23 mm hole and a compression gland. The second question is the contact rating against the load: a float switch that drives a solenoid directly is the most common failure in this family, and the fix is an interposing relay rather than a bigger contact.

The third question is the liquid. The body material follows the chemical, and the float follows the specific gravity: a float sized for water sits higher in a light solvent and the switch point moves with it. Both are decided from the liquid data sheet, not from the temperature alone.

Where a body has been superseded, the usual route is the same switch point in another material or the external fitting version, since the thread and the lead length are what the tank was built around. See lead time and availability for a specific code, and obsolete part cross reference where a tank is being refurbished.

The SUPERB Assembly team fits the gasket dry and tightens the nut by hand plus a quarter turn, because a crushed gasket on a nylon body leaks at the thread rather than at the seal.

Q: Can you confirm the tank wall thickness and the thread, and whether the load is a relay coil or a solenoid, because the contact rating and the mounting both depend on it?

A: Yes. Send the liquid, the specific gravity, the temperature, the tank wall thickness, the thread and the load the contact has to switch, and the SUPERB Tech team returns the body and the rating that fit.

Why Equipment Builders Source Float Switches Through SUPERB

  1. Mounting and thread stated: internal and external fitting bodies are listed with their thread and hole size, so the tank is drilled once.
  2. Contact rating against load type: 25 VA and 100 VA are quoted with the voltage and current limits and a note on inrush, which is where these switches actually fail.
  3. Material chosen on the liquid: four bodies are listed with their temperature and their approvals, so a potable water line is not built from a general purpose part.
  4. Lead and cable options listed: PVC and ETFE leads with the temperature each one allows, because the cable is the first thing to fail on a hot tank.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Liquid Flow Sensors for Medical and Analytical Instruments, Ultrasonic Transducers and Distance Sensors, Inductive Proximity and Photoelectric Sensors, Differential Pressure Sensors for Ventilators and Process Lines, Nylon Grommets and Hole Plugs for Panel Openings, Component Lead Time Solutions.