Liquid Flow Sensors for Medical and Analytical Instruments
Product Specifications
Product Overview
A dosing loop is only as good as the flow signal it closes on. A paddle wheel or a turbine gives a pulse per revolution, which means the reading lags the flow by the time the rotor takes to speed up and slow down, and at low flow rates the rotor may not turn at all. A thermal sensor on the outside of a capillary measures the heat carried away by the liquid, so the response is in milliseconds and there is no minimum flow below which it stops reading.
The second advantage is that nothing is in the fluid path. The sensor chip sits outside a PPS or stainless channel, so the wetted materials are the channel, the seal and the fitting, and there is no rotor, no bearing and no shaft to wear or to trap air. That is what lets the same measuring principle be used on an infusion line, where sterility and cleaning are the constraint, and on a coolant loop, where debris would jam a mechanical rotor.
The third decision is the range. A 2 ml per minute sensor resolves a few microlitres and saturates around 3.25 ml per minute. A 40 ml per minute sensor covers a reagent line at 5 percent of reading. A 600 ml per minute sensor covers a coolant or a dialysate loop, with 5 percent accuracy up to half scale and 10 percent above it. Choosing a sensor two ranges too large is the usual mistake: the reading is inside the accuracy band but it is a small fraction of full scale, and the resolution at the working point is what actually matters.
Key Specifications
| Parameter | Value | Note |
|---|---|---|
| Measuring principle | thermal, CMOS chip outside the flow channel | no moving parts in the fluid path |
| Full scale range | 2 ml per minute, 40 ml per minute, 600 ml per minute, 1000 ml per hour | four families, bi-directional |
| Sensor output limit | 3.25 ml per minute on the 2 ml sensor, 1000 ml per minute on the 600 ml sensor | the output saturates above full scale |
| Accuracy in water | 5 percent of reading or 0.5 ul per minute on the small range, 5 percent or 0.5 ml per minute to 300 ml per minute on the large range | larger error is the one that applies |
| Accuracy in IPA | 10 percent of reading on the small and large ranges | the sensor is calibrated for both media |
| Repeatability | 0.5 percent of reading plus a fixed floor per range | at constant temperature |
| Response time | below 20 ms, warm up 50 to 60 ms | thermal principle, no rotor inertia |
| Interface | I2C at 400 to 1000 kHz, RS485 on the larger body | 16 bit signed flow value, scale factor per range |
| Supply | 3.2 to 3.8 V, 6 mA maximum in measurement | 3.5 V nominal |
| Wetted materials | PPS, stainless steel 316L, epoxy adhesive | plus the seal and the fitting chosen at install |
| Maximum pressure | 12 bar on the 2 ml and 40 ml sensors, 3 bar on the 600 ml sensor | burst pressure 25 bar and 9 bar respectively |
| Fluid connection | 1/4-28 UNF flat bottom on the small bodies, 5 to 6 mm barb on the large body | fitting torque 0.5 Nm on the UNF port |
| Operating temperature | plus 5 to plus 50 C | liquid and ambient within that band for stated accuracy |
| Diagnostics | air in line flag and high flow flag | the flags are read with the flow value over the same interface |
| Calibration media | water and isopropyl alcohol | other media need a calibration check at the working point |
Included Models and Order Codes
The four ranges are chosen from the working flow, not from the largest number in the catalogue. SLF3S-0600F covers 2 ml per minute bi-directionally with a 3250 ul per minute output limit, 5 percent accuracy and an inner volume of 28 ul, which is the sensor for a reagent or a drug line where a few microlitres decide the dose. SLF3S-1300F covers 40 ml per minute with an inner diameter around 1.4 mm and a 58 ul volume, and it is the general purpose body for an analyser. SLF3S-4000B covers 600 ml per minute through a 5 to 6 mm barb, with 5 percent accuracy up to 300 ml per minute and 10 percent up to full scale, which is the coolant and dialysate range. LD20-2600B is the single use version: 1000 ml per hour full scale with 5 percent accuracy in a body made for a disposable line, which is what a peristaltic infusion set needs.
| Model | Full scale | Accuracy in water | Fluid connection | Pressure |
|---|---|---|---|---|
| SLF3S-0600F | 2 ml/min, output limit 3.25 ml/min | 5 percent or 0.5 ul/min | 1/4-28 UNF flat bottom | 12 bar, burst 25 bar |
| SLF3S-1300F | 40 ml/min | 5 percent or 0.05 ml/min | 1/4-28 UNF flat bottom | 12 bar |
| SLF3S-4000B | 600 ml/min, output limit 1000 ml/min | 5 percent to 300 ml/min, 10 percent above | 5 to 6 mm barb | 3 bar, burst 9 bar |
| LD20-2600B | 1000 ml/h | 5 percent | single use line body | per maker sheet |
| Gems FS-3 165840 | 0.05 GPM set point | switch, not a measurement | 1/4 inch male NPT | 150 psi at 70 F |
| Gems FS-3 165841 | 0.25 GPM set point | switch, not a measurement | 1/4 inch male NPT | 150 psi at 70 F |
| Gems FS-3 165842 | 0.50 GPM set point | switch, not a measurement | 1/4 inch male NPT | 150 psi at 70 F |
| Gems FS-3 165843 | 1.00 GPM set point | switch, not a measurement | 1/4 inch male NPT | 150 psi at 70 F |
Range Conversion for the Four Bodies
The same flow appears in microlitres per minute in a drug line specification and in gallons per minute in a coolant drawing, so the ranges are converted here once. The figures are the full scale of each body expressed in the four units that turn up in customer documents, calculated from the published full scale. A line that runs at 0.2 GPM sits at 757 ml per minute, which is above the 600 ml per minute body and needs a switch or a larger sensor rather than a sensor run at the top of its range.
| Body | Microlitres per minute | Millilitres per minute | Litres per hour | US gallons per minute |
|---|---|---|---|---|
| SLF3S-0600F | 2000 | 2 | 0.12 | 0.00053 |
| SLF3S-1300F | 40000 | 40 | 2.4 | 0.0106 |
| SLF3S-4000B | 600000 | 600 | 36 | 0.159 |
| LD20-2600B | 16667 | 16.7 | 1.0 | 0.0044 |
| Gems FS-3 maximum | 3785 | 3.79 | 0.227 | 1.00 |
Key Features
No moving parts – the chip sits outside the channel, so there is no rotor to jam, no bearing to wear and no minimum flow below which the reading stops.
Response below 20 ms – a dosing valve can be closed on the measured flow rather than on a calculated volume, because the signal follows the liquid in milliseconds.
Bi-directional measurement – the sign of the flow is part of the value, which is what a loop with a reversible pump or a syringe cycle needs.
Calibrated for two media – water and isopropyl alcohol are both calibrated, and the difference between them is stated, so a cleaning cycle reads correctly.
Air in line flag – the digital bodies report air in line and over range as flags on the same interface, which turns a bad reading into a diagnosable event.
Wetted materials stated – PPS, 316L stainless steel and epoxy, with the seal and fitting chosen at installation, so the fluid compatibility check has a starting list.
Pressure rating per body – 12 bar on the small bodies and 3 bar on the large one, with burst pressure stated, so a closed valve downstream is a pressure check rather than a surprise.
Switch option for go and no go – the FS-3 piston switch gives a fixed set point from 0.05 to 1.00 GPM where a measurement is not needed, at 20 VA contact rating.
Applications
Three instrument loops where the sensor range and the fluid path decide the model.
Infusion and drug delivery – a 2 ml per minute body reads the dose directly, and the air in line flag stops the pump before an air bubble reaches the patient line.
Laboratory analysers and dilution – a 40 ml per minute body sits on the reagent line, with 5 percent accuracy and a 58 ul inner volume that keeps the dead volume small.
Coolant and dialysate loops – a 600 ml per minute body with a barb connection covers the flow, and the switch bodies cover the go and no go check on a filter or a pump.
A flow sensor usually arrives on a small interface board, so the SUPERB PCBA and the SUPERB PCB are checked against the same fluidic layout and the connector orientation is reviewed once for both.
Sourcing and Cross-Reference
The first question is the working flow, not the maximum. A 600 ml per minute body run at 20 ml per minute is inside its accuracy band but far from its resolution, and the same money buys a 40 ml per minute body that reads properly. The second question is the fluid: the published accuracy is for water and IPA, and a reagent with a different viscosity needs a check at the working point.
The third question is the connection. The 1/4-28 UNF port takes a flat bottom fitting at 0.5 Nm, and the barb body takes 5 to 6 mm tubing. Mixing the two means an adapter, and an adapter in front of a thermal sensor changes the flow profile that the calibration assumed.
Where a body is not in the range, the usual route is the next size up with a calibration check, or a switch body where only a go and no go answer is needed. See lead time and availability for a specific model, and how to verify a drop in replacement where a sensor is being changed inside an existing instrument.
The SUPERB Assembly team keeps the sensor body level during the first power up and flushes the line before calibration, because a trapped bubble reads as a low flow rather than as a fault.
Q: Can you confirm the working flow and the fluid, because the accuracy we quote is for water and IPA and the body has to be sized on the working point rather than on full scale?
A: Yes. Send the working flow range, the fluid, the pressure, the connection type, the interface the controller uses and the ambient temperature, and the SUPERB Tech team returns the body and the calibration that fit.
Why Instrument Builders Source Liquid Flow Sensors Through SUPERB
- Range chosen on the working point: each body is quoted with its full scale and its output limit, so a sensor is not run in the bottom tenth of its range.
- Fluid path described: wetted materials, inner volume and connection are given per body, because the dead volume and the fitting decide the reading as much as the chip.
- Diagnostics included: air in line and over range flags are part of the interface, which turns a bad reading into something a service technician can act on.
- Switch and sensor kept apart: the piston switch bodies are listed as switches, so a go and no go requirement does not turn into an unnecessary measurement channel.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Differential Pressure Sensors for Ventilators and Process Lines, Level Sensors and Float Switches for Tanks and Sumps, Temperature and Humidity Sensors, Industrial Pressure Sensors and Transducers, IEC 60601 Power Supplies for Medical Diagnostic Equipment, Component Lead Time Solutions.