Draw Latches and Toggle Latches for Enclosure Doors A draw latch pulls a door closed and holds it with an over centre action, so the clamping force and the keeper position are what decide the fit. The over centre latches here run from 135 N in the small size to 670 N in the medium heavy duty size, in steel, zinc plated steel and stainless. Pull action toggle latches cover 1600 to 8900 N, with a threaded U hook that takes up 9.1 to 24.6 mm of adjustment on the door. Latch and keeper are separate parts on the over centre range, so both are quoted together and both appear on the door drawing.
Eyelets and Rivets for Panel and Board Fixing An eyelet lines a hole and gives a screw or a pin a metal seat, and its length is chosen from the panel stack, not from the hole size. The brass eyelets here run from a 0.062 in barrel to a 0.156 in barrel, with flanges from 0.125 to 0.245 in and four mounting hole sizes. Lengths under the flange cover 0.062 to 0.250 in, so a 1.6 mm board and a 6.4 mm panel stack are both served by the same page. Nylon snap rivets cover panel stacks from 0.051 to 0.335 in and press in without tooling, which is the route for a cover that may come off again.
Butt Splices and Crimp Connectors for Wire Joins A butt splice joins two wires end to end, and the barrel length and the wire stop are what decide whether the joint holds. The parts here run from a 26-22 vinyl splice to a 12-10 sealed heat shrink splice, in vinyl, nylon, polyolefin and NiAc insulation. Voltage follows UL 486C at 600 V for most parts, with the 12-10 vinyl splice down at 300 V when a 10 AWG solid wire is used. Strip length and crimp tool are listed per family, because a 5/16 in strip in a 9/32 in barrel leaves copper outside the crimp.
Braided Sleeving and Expandable Sleeves for Harness Protection Braided sleeving protects a harness against abrasion and still lets it bend, which is why it is used where a conduit would be too stiff. The self-wrapping sleeve here runs from 3.2 mm to 50.8 mm nominal, with a 10 mil PET braid, a 25 percent edge overlap and walls from 0.61 mm to 0.97 mm. The expandable sleeve covers 1.59 mm to 50.8 mm nominal and opens to between 1.5 and 1.75 times its nominal size, which is what lets it pass a connector. Nominal size, expansion range, wall thickness and temperature are given per part number.
Wire Ferrules and Crimp Sleeves for Terminal Blocks A stranded wire in a screw clamp spreads, and a ferrule is what turns the strands into a solid pin that the clamp can hold. The ferrules here run from 0.5 mm2 at 1.1 mm ferrule diameter to 2.5 mm2 at 2.3 mm, in 14 mm sleeve length with 8 mm contact length. Twin ferrules take two 2.5 mm2 conductors into one 10 mm contact range, for a terminal that has to take a pair. Conductor size, sleeve length, contact length, ferrule diameter and stripping length are given per size, because the collar is what decides fit.
Cable Markers and Wire Labels for Harness Identification A harness is only as good as the legend on it, and the legend survives only if the marker is the right size for the wire. The slide on markers here cover 1.0 to 3.0 mm, 2.0 to 5.0 mm and 4.0 to 9.0 mm bundles, in PVC rated from -65 to 105 C. The printable tags cover 5.5 mm to 15 mm widths and 50 mm to 100 mm lengths, in halogen free polyolefin tied with a cable tie up to 4.6 mm wide. Bundle range, length, material and temperature are given per type, because a marker that is one size out slides along the wire.
Heat Shrink Tubing and Sleeves for Harness Protection Heat shrink is chosen by recovered diameter, not by the size printed on the reel, and that is where most harness drawings go wrong. The 2:1 tubing here runs from 1.17 mm to 50.8 mm expanded, with recovered diameters down to half of that and walls from 0.41 mm to 1.14 mm. The 3:1 adhesive lined tubing runs from 3.18 mm to 38.1 mm expanded, with a meltable inner wall that seals the joint as it shrinks. Expanded diameter, recovered diameter, recovered wall and minimum shrink temperature are given per size.
Threaded Inserts and Standoff Nuts for Plastic Enclosures A thread in a plastic boss strips after a few assembly cycles, so the thread is put into a brass insert instead of into the moulding. The heat set inserts here run from M2 at 3.2 mm outside diameter to M6 at 8.2 mm, with lengths from 3.0 mm to 9.5 mm and hole sizes from 3.0 mm to 8.0 mm. The self-clinching nuts cover M2 to M6 for the metal bracket or chassis that the plastic case is fixed to. Hole size, insert length, recommended boss diameter and minimum sheet thickness are given per part, because the boss is what fails first.
Nylon Grommets and Hole Plugs for Panel Openings A raw hole in a panel cuts cable, and an open hole in a panel passes dust, so both ends of the problem are solved with one moulded nylon part. The bushings here cover 6.4 mm to 22.2 mm holes with inside diameters from 3.2 mm to 15.9 mm, for panels up to 3.2 mm thick. The dome plugs cover 4.7 mm to 50.8 mm holes, with a head thickness of about 1.6 mm and locking fingers that take panels up to 6.4 mm. Hole diameter, inside diameter and maximum panel thickness are given per part, because those three figures decide whether the part fits at all.
Mounting Brackets and DIN Rail Clips for Enclosures An end bracket is the part that stops a bank of terminals from sliding, and its width is what sets the pitch of the whole row. The brackets here are 5.2 mm, 8 mm and 9.5 mm wide, for NS 35/7.5 and NS 35/15 rail, in PA or Wemid from HB to V0. Depth on rail runs from 33.5 mm on the 9.5 mm bracket to 46.5 mm on the 8 mm Weidmuller part, which is the figure that decides whether the door closes. The rail itself is 35 mm wide steel to EN 60715, perforated on a 25 mm pitch, and rated for a 1.92 kA short-time current for one second.
Grounding Studs and Earth Terminals for Chassis Wiring A chassis bond is only as good as the metal under the lug, so the stud is chosen by panel thickness and by the fault current it has to carry. The studs here run from a self-clinching M6 part in 1.0 mm sheet to a self-piercing M6 part in 2.2 mm aluminium, plus CD weld studs in 1/4-20, M6 and M8. Rail earth terminals cover 0.14 to 4 mm2 in screw connection on NS 35/7.5 and NS 35/15 rail. Hole size, minimum centre distance to the edge, pull-out and torque-out are given per part, because those four figures decide whether the bond holds.