Brass cable glands that bond a cable shield to the enclosure at the entry, with a brush that touches the braid in one step. Contact resistance is 10 mOhm or less over a 360 degree contact area, which is what a drive cable needs at both ends. Sizes run M16 to M110 with IP68 to 10 bar and IP69 on the metric range, with strain relief to category A. Rail mounted shield clamps from 3 mm to 22 mm are listed for cables that are bonded inside the cabinet.
quote now

Product Specifications

Product Overview

An EMC problem on a machine is usually a shield problem, and the shield problem is usually at the entry. A braided screen that is twisted into a pigtail and landed on a terminal has an inductance high enough to make the shield useless above a few megahertz, while the same screen bonded around its full circumference at the gland gives a low impedance path at the frequencies that actually cause the fault. The gland is therefore not a mechanical part with an electrical side effect, it is the electrical part.

A brush gland does the bonding in one step. The cable is inserted, the braid is folded back over the brush, and tightening the cap pushes the brush onto the braid around the whole circumference. There is no separate spring, no cutting ring and no need to bring the braid out to a clamp. The result is a contact resistance in the order of a few milliohms and a seal that still holds IP68, which is why this brush type has replaced the older split insert type on drive and servo cables.

Inside the cabinet the same job is done by a shield clamp on the rail. A clamp is used where the cable does not pass through a gland, for example a screened pair that lands on a terminal block, or where the screen has to be bonded at a second point close to the drive. The clamp gives a 360 degree contact with spring pressure and no adjustment, and the rail mounting means the bonding point can be added to an existing cabinet without drilling.

Key Specifications

ParameterValueNote
Thread sizesM16 x 1.5 to M110 x 2.0 to DIN EN 60423plus NPT versions in the same family
Clamping range4.5 to 10 mm on M16, 34 to 45 mm on M63the range is printed per size on the maker table
Shield contactbrass brush, 360 degree contact areathe braid is folded over the brush, no separate clamp
Transfer impedance10 mOhm or lessthe figure that decides whether the bond works above 1 MHz
Degree of protectionIP68 at 10 bar for M20 to M50, 5 bar at M63, IP69 on the metric rangeIP69 excludes the M63 plus size
Temperature range-40 to +100 C static, -25 to +100 C dynamicthe seal material sets the limit
Strain reliefcategory A to DIN EN 62444the gland holds the cable as well as the shield
Materialnickel plated brass body, brass brush, polyamide insert, elastomer sealsalt spray tested 168 hours at 35 C
Locknutseparate item, SM-PE-M for the metric rangean EMC gland needs an EMC locknut to bond through a painted wall
ApprovalsUL file E79903, tested to UL 514BType 1, 4X, 6 and 12 to UL 50 E
Shield clamp sizes3 to 12 mm, 6 to 8 mm, 17 to 22 mmsingle clamp bodies on a 35 mm rail
Shield clamp materialzinc plated spring steelvibration proof, no adjustment needed

Included Models and Order Codes

The gland rows are the metric sizes of one family, so the order code and the clamping range are what distinguish them; the size is in the part number block and the range is in the table. The shield clamps are a second family with their own numbering: the six digit number is the article number and the type name carries the shield diameter range, so SF|SKL 6-8 is the clamp for a 6 to 8 mm shield and SF|SKL 17-22 is the larger body. Where a locknut or an O ring is needed, it is a separate order line and is noted as such.

Part numberTypeThread or shield rangeClamping rangeProtectionNote
5311 2506LAPP SKINTOP MS-M BRUSHM16 x 1.54.5 to 10 mmIP68, 10 barbrush contact, nickel plated brass
5311 2507LAPP SKINTOP MS-M BRUSHM20 x 1.57 to 13 mmIP68, 10 barthe most common entry on drive and servo cables
53112676LAPP SKINTOP MS-M BRUSHM25 x 1.59 to 17 mmIP68, 10 barshield above braiding 6 to 13.5 mm
53112677LAPP SKINTOP MS-M BRUSHM32 x 1.511 to 21 mmIP68, 10 barshield above braiding 8 to 18 mm
53112678LAPP SKINTOP MS-M BRUSHM40 x 1.519 to 28 mmIP68, 10 barshield above braiding 10 to 26 mm
53112679LAPP SKINTOP MS-M BRUSHM50 x 1.527 to 35 mmIP68, 10 barshield above braiding 14 to 36 mm
53112680LAPP SKINTOP MS-M BRUSHM63 x 1.534 to 45 mmIP68, 5 barshield above braiding 20 to 40 mm
53112681LAPP SKINTOP MS-M BRUSHM63 x 1.5 plus44 to 55 mmIP68, 1 barfor large cables, IP69 not covered
53112501LAPP SKINTOP MS-M BRUSHM75 x 1.553 to 63 mmIP68, 1 bardouble lamella seal
53112503LAPP SKINTOP MS-M BRUSHM90 x 2.066 to 78 mmIP68, 1 barUL and VDE approval pending on this size
36245Icotek SF|SKL 6-86 to 8 mm shieldn/an/a50 x 14 x 22 mm, 35 mm rail, spring steel
36248Icotek SF|SKL 17-2217 to 22 mm shieldn/an/a50 x 26 x 41 mm, 35 mm rail
MSKL 3-12Icotek MSKL3 to 12 mm shieldn/an/a26 mm wide, up to 3 cables, optional strain relief by cable tie
36875.150 (SF2Z|SKL 17-22)Icotek SF2Z|SKL17 to 22 mm shieldn/an/atwo clamps on one foot, strain relief function

Where the Shield Has to Be Bonded

A shield works only if it is bonded at both ends and bonded around its circumference. The table below covers the four places that matter on a machine, and the part that does the job at each one.

Place on the machineBonding partWhy it matters
Cable entry into the drive cabinetEMC gland, braid folded over the brushthe bond is at the enclosure wall, so the surge and the noise stay outside
Motor terminal boxEMC gland or a clamp on the framea pigtail at the motor end radiates the common mode current that the drive created
Screen lands on a terminal block inside the cabinetrail mounted shield clampthe braid is bonded where it ends rather than being carried to an earth stud
Two cabinets with a screened bus cableclamp at both entriesa bond at one end only turns the screen into an antenna

Key Features

Brush contact in one step – the braid is folded over the brush and the cap is tightened, which removes the cutting ring and the separate clamp from the assembly.

360 degree contact – the brush touches the braid around the full circumference, which is the low impedance path a pigtail cannot give.

Contact resistance stated – 10 mOhm or less transfer impedance, a figure that can be compared with the bond at the other end.

Seal and strain relief together – IP68 to 10 bar and category A strain relief from the same body, so the electrical and the mechanical job are not split.

Large sizes with a lamella seal – M75 to M110 use a double lamella gasket, which keeps a heavy cable sealed without a second entry.

Rail clamps for inside the cabinet – 3 to 12 mm and 17 to 22 mm clamps on a 35 mm rail add a bonding point without drilling the plate.

Applications

EMC glands and clamps are fitted wherever a shielded cable enters or ends, and the three cases below cover most of the panel work.

Variable speed drive motor cables – the drive creates a common mode current that returns on the screen, and a gland at each end gives that current a short path instead of letting it find one through the encoder cable.

Servo and encoder cables – the encoder signal is small and the cable runs beside the motor cable, so a 360 degree bond at the cabinet entry is what keeps the position feedback clean.

Instrument and communication entries in process panels – a screened pair that lands on a terminal block is bonded with a rail clamp, which keeps the screen continuous without a pigtail at the block.

The motor cable entry and the control board share a cabinet wall, so the SUPERB PCBA and the SUPERB PCB are reviewed against the same bonding plan and the same earth bar.

Sourcing and Cross-Reference

An EMC gland order is decided by three numbers: the thread, the cable diameter and the shield diameter above the braid. The first two are on the cable data sheet, and the third is the one that is usually missing, which is why the maker table prints it as a separate column. A gland that clamps the cable but not the braid is a mechanical gland with an EMC price.

The locknut is the second trap. An EMC gland bonds through its body to the enclosure wall, so the wall has to be conductive at that point. On a painted cabinet the bond is made by an EMC locknut with serrated contact or by scraping the paint, and a standard locknut leaves the gland isolated. That single item decides whether the installation works.

For cables that are already terminated, the rail clamp is the practical answer, because it can be added without removing the gland. See lead time and availability for a specific size and BOM shortage recovery where a panel is waiting on one gland size.

The SUPERB Assembly team bonds the gland to bare metal with an EMC locknut rather than relying on a painted surface, because a painted joint is an open circuit at radio frequency.

Q: Can you confirm the clamping range and the shield diameter above the braid for this cable before we fix the gland size?

A: Yes. Send the cable diameter, the shield diameter above the braid, the thread and the wall thickness, and the SUPERB Tech team returns the gland and the locknut that fit.

Why Panel Builders Source EMC Glands From SUPERB

  1. Shield diameter as a column: the range above the braid is listed next to the clamping range, which is the number that is missing from most cable data sheets.
  2. Contact resistance published: 10 mOhm or less transfer impedance is the figure that makes the bond comparable at both ends of a cable.
  3. Seal and strain relief together: IP68 and category A strain relief are stated on the same row, so the gland is not chosen on one and checked on the other.
  4. Clamps for inside the cabinet: rail mounted clamps sit on the same page, which covers the screen that ends on a terminal block rather than at a wall.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Cable Glands and Strain Relief Bushings for Enclosure Entries, Cable Entry Plates and Brush Grommets for Cabinet Bases, EMI Shielding Cans and Contact Gaskets for RF Boards, Earthing Braids and Bonding Straps, Ferrite Beads and EMI Suppression Filters for Board Noise.