Guard Locking Devices and Solenoid Door Locks

Guard locking devices that hold a door shut until the hazard has actually ended, not just until the stop command is given. Holding force runs from 1,000 N on a light process guard to 10,000 N on a heavy machine door. Three families are listed with their coding level, safety rating and the force each mounting position gives. Release options, escape release and manual override are shown per part, because they decide the door hardware.
quote now

Product Specifications

Product Overview

A door interlock tells the controller that a guard is closed. A guard locking device also keeps it closed, and that difference matters on any machine that keeps moving after the stop command. A spindle, a flywheel, a robot arm or a press ram can take several seconds to come to rest, and a door that can be opened in that window is a door that will be opened in that window. Guard locking is the function that removes the window.

The first number is holding force, and it is not a comfort figure. A large machine door with a sealing lip, a slight frame twist or a negative pressure inside the enclosure already pushes against the lock before anyone touches the handle. A 1,000 N device suits a light aluminium guard on a packaging cell, a 7,500 N device suits a machine tool door, and a 10,000 N device exists for heavy doors that are pulled by their own weight. Some devices also allow release against a lateral force, which is what stops a door from jamming when the frame settles.

The second number is the safety rating of the locking function itself, and this is where families differ most. On a device rated PL e for both interlocking and guard locking, the lock is monitored, so a stuck bolt is detected and the machine cannot start. On a device meant for process protection, the lock holds the door but the safe monitoring of the bolt is not part of the safety function, and that is a legitimate choice only when the hazard is process related rather than personal. Reading which of the two a part is rated for decides whether it can be used on the guard at all.

Key Specifications

ParameterValueNote
Holding force FZh1,000 N, 7,500 N and 10,000 N across the three familiesmaximum force Fmax is 1,300 N, 13,000 N and 15,000 N respectively
Holding force by mounting position7,500 N with screws parallel to the actuator, 5,000 N with screws side onPilz PSEN ml b table, the bracket decides which figure applies
Release against lateral forceup to 300 NSchmersal AZM400, for doors that bind on their seal
Latching force30 NPSENmlock, keeps a light door closed before the bolt engages
Safety ratingPL e / category 4 / SIL 3 for interlocking and guard lockingEuchner CTM-L2-BR is rated for process protection, without safe lock monitoring
CodingRFID high coding to ISO 14119, teach once or re teachablere teaching on the Schmersal I2 version has a 10 minute delay
Actuator tolerance+/-4 mm in X and Y, 1 to 7 mm gap, 2 degrees anglePSENmlock allows +/-3 mm and +/-2 to 7.5 degrees on three axes
Mechanical life1,000,000 operationsall three families
Degree of protectionIP66 / IP67, IP65 / IP67, IP69 on the Pilz partIP69 needs the cable protected from high pressure cleaning
Supply24 V DCPSENmlock allows +20 / -20 percent, output current 100 mA
Outputs2 safety outputs plus 1 diagnostic output, or 2 OSSDtwo channel input for the locking function on the AZM400
ConnectionM12 8 pin, M12 12 pin or pigtailcable length up to 50 m on the Pilz part
Body size157 x 78 x 47 mm, 217.2 x 40 x 40 mm, and a compact thermoplastic bodyAZM400, PSENmlock, CTM
Manual releaseemergency release knob, auxiliary release, or electric manual release on auxiliary voltagean escape release is a separate order line on the Pilz part

Included Models and Order Codes

The order code of a guard locking device carries the safety function, the coding level and the release option, so two parts that look identical can differ in what they are rated to do. On the Schmersal AZM400 the block after ST names the coding: a plain 1P2P body is the standard version, I1 is individually coded and taught once, and I2 is individually coded and can be re taught after a 10 minute delay. On the Pilz PSEN ml range the letter after ml tells the housing and the number tells the version, and a unit ships with its actuator while a switch ships without one. The Euchner CTM-L2-BR is quoted with its full order number, because the connection and the release option are part of it.

Part numberFamilyHolding forceSafety ratingCodingNote
AZM400Z-ST-1P2P (103003590)Schmersal AZM40010,000 N, 13,000 N maxPL e / cat 4 / SIL 3standard, actuator not individually codedM12 8 pin, IP66 / IP67, bistable motor bolt
AZM400Z-ST-I1-1P2P (103003732)Schmersal AZM40010,000 N, 13,000 N maxPL e / cat 4 / SIL 3individually coded, taught oncefor a guard where a spare actuator must not be able to close the circuit
AZM400Z-ST-I2-1P2P (103003733)Schmersal AZM40010,000 N, 13,000 N maxPL e / cat 4 / SIL 3individually coded, re teachable after 10 minutesthe service friendly version of the same lock
AZM400Z-ST-1P2P-BOW (103015314)Schmersal AZM40010,000 N, 13,000 N maxPL e / cat 4 / SIL 3standardwith the mounting set for a 40 mm aluminium profile
PSEN ml b 1.1 unit (570400)Pilz PSENmlock7,500 N parallel, 5,000 N side onPL e / cat 4 / SIL 3codedswitch plus actuator, 8 pin M12, IP67, 1,000,000 cycles
PSEN ml b 1.1 switch (570401)Pilz PSENmlock7,500 N parallel, 5,000 N side onPL e / cat 4 / SIL 3codedswitch only, order the actuator separately
PSEN ml b 2.1 unit (570402)Pilz PSENmlock7,500 N parallel, 5,000 N side onPL e / cat 4 / SIL 3codedseries connection version
PSEN ml b 2.2 unit (570404)Pilz PSENmlock7,500 N parallel, 5,000 N side onPL e / cat 4 / SIL 3codedseries connection with power reset
PSEN ml s 1.1 unit (570406)Pilz PSENmlock7,500 N parallel, 5,000 N side onPL e / cat 4 / SIL 3fully codedhigher coding level than the b version
PSEN ml 1.1 actuator (570480)Pilz PSENmlockn/an/acodedspare actuator for the 1.1 version
PSEN ml escape release (570460)Pilz PSENmlockn/an/an/aescape release for a gate where a person can be locked inside
CTM-L2-BR-U-AZ-SA-168866Euchner CTM1,000 N, 1,300 N maxprocess protection, no safe lock monitoringunicode, high codingIP65 / IP67, 24 V DC, 500 mA, open circuit principle

What Decides the Holding Force You Need

Holding force is chosen from the door, not from the machine size. Four things push against a lock, and any one of them can be larger than the weight of the door itself.

Load on the doorHow it shows upWhat to check
Sealing lip compressiona constant pull of tens to hundreds of newtons once the door is shutthe seal maker gives N per metre of gasket, multiply by the door perimeter
Frame twist and settlingthe bolt binds and the door will not releasechoose a device with release against lateral force, or a bracket that allows alignment
Negative pressure inside the cabinetthe door is pulled inward while a fan or a filter runsa fan rated at 100 m3/h against a small free area is enough to load the lock
Door weight on a vertical hingethe lock carries part of the weight when the hinge wearsa 10,000 N device on a heavy door also protects the hinge line

Key Features

Holding force per mounting position – the same device gives 7,500 N or 5,000 N depending on how the screws sit relative to the actuator, and that is stated here instead of being left in an installation note.

Three safety levels visible – PL e for interlocking and guard locking, PL e for interlocking with process locking, and process protection only, are three different products and are labelled as such.

Coding levels named – standard, individually coded and re teachable versions are separate rows, so a spare actuator cannot quietly close a safety circuit.

Release options listed – emergency release, auxiliary release and electric manual release are part numbers of their own, which keeps the door hardware on the same order.

Bistable bolt on the heavy range – the motor driven bolt keeps its last position when power fails, so a door does not spring open during a power dip.

Tolerance stated in millimetres – the actuator gap and the angular offset are given per family, because a sagging gate is the usual reason a lock reports a fault.

Applications

These devices are chosen by what the guard has to survive, so the three cases below cover most of the machines we quote for.

Machine tools and machining centres – a spindle takes seconds to stop and the door is heavy, so a 10,000 N bolt with a bistable action holds the guard through a power dip and through the run down.

Robot cells and assembly equipment – a light guard with a coded actuator is enough, and the coding stops a second actuator from being used to defeat the interlock during a maintenance shift.

Packaging and printing machines with process guards – where the risk is a jammed web rather than a person, a process protection lock with 1,000 N holding force keeps the guard closed without claiming a safety function it does not have.

The guard circuit is wired into the panel that also carries the SUPERB PCBA, so the SUPERB PCB and the safety relay inputs are checked on one drawing rather than two.

Sourcing and Cross-Reference

A guard locking device is bought with its actuator and its brackets, and those are three order lines that fail together if one is missed. The unit versions here include the actuator, the switch versions do not, and a mounting plate or bracket for a sliding or swinging door is a separate number in both families. The first check on a replacement is therefore what is already on the door frame, not what is on the drawing.

The second check is the safety function. Upgrading a process lock to a PL e lock changes the wiring, because the safe version needs a two channel input for the locking function and usually a different safety relay input pattern. Downgrading is worse: a PL e guard cannot be served by a process lock even if the holding force is higher, and the machine's risk assessment is what settles the question.

Where a part is on a long lead time, the practical options are the same device with a different coding level, the switch version plus a stocked actuator, or a bracket change that allows another family on the same frame. See lead time and availability for a specific number and obsolete part cross reference where an older lock has been withdrawn.

The SUPERB Assembly team keeps the two safety channels on separate terminals with their own ferrules, because a shared terminal is the most common way a two channel guard circuit becomes a single channel one.

Q: Can you confirm the holding force for the way this lock will be mounted, and whether the locking function is rated for personnel protection?

A: Yes. Send the door weight, the frame drawing, the required safety category and the release options, and the SUPERB Tech team returns the device, the actuator and the bracket that fit.

Why Machine Builders Source Guard Locking From SUPERB

  1. Force and mounting together: the holding force is given per fixing direction, which is the figure that actually applies once the bracket is on the door.
  2. Safety function stated per part: PL e locking, process locking and plain interlocking are not mixed in one row, so the risk assessment and the part number agree.
  3. Coding and release as order lines: actuator, escape release and manual release are listed with their own numbers, so the door hardware arrives complete.
  4. Families side by side: three makers with three force classes are on one page, which is what a mixed machine line needs when only one door is heavy.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Door Interlock Switches for Safety Circuits, Safety Relay Modules for Guard Monitoring, Safety Light Curtains for Machine Guarding, Enclosure Door Stays and Retaining Clips, Mounting Brackets and DIN Rail Clips for Enclosures.