PV and DC Surge Protective Devices for String Combiners DC surge arresters for the string side of a photovoltaic plant, rated 1000 V or 1500 V continuously. Type 2 modules carry 25 kA to 40 kA at 8/20, and the type 1 version adds 6.25 kA at 10/350 per pole. Short circuit current rating and the open circuit failure mode are stated, because a PV array cannot be switched off. Enclosure versions and DIN rail versions are listed with their protection level and response time.
Photovoltaic Fuse Links for PV Strings and Battery Racks gPV fuse links built for the DC arc of a photovoltaic string, in 1000 V and 1500 V DC ratings. 10 x 38 mm midget bodies cover 1 A to 30 A, and 10 x 112 mm bodies cover 10 A to 25 A for larger strings. Breaking capacity is 20 kA up to 20 A and 50 kA at 25 and 30 A, with ferrule, PCB tab and crimp cap terminals. Pre-arcing I2t and watts loss are listed per part, because string sizing is done on current and on heat.
Surge Protective Devices for Signal and Data Lines Pluggable protectors that sit on a signal pair and clamp the surge before it reaches the input card. A 24 V module carries 10 kA per line at 8/20 and 2.5 kA per line at 10/350, so it covers a zone boundary. Line to line clamping is 45 to 52 V, which is the figure an analogue input is compared against. Series resistance, cut off frequency and capacitance are listed, because a loop has to keep working after the module is fitted.
Anti Condensation Heaters for Electrical Enclosures Small PTC heaters that hold a cabinet a few degrees above the dew point, which is what stops condensation on terminals. Radiant versions from 10 W to 30 W warm a single cold spot, convection versions from 15 W to 150 W warm the whole box. Fan heaters from 200 W to 800 W spread the heat when the cabinet is large or the ambient swings fast. Mounting, inrush current and surface temperature are listed per part, since they decide the fuse and the clearance.
Contactor Coil Suppression Modules and RC Networks Suppressor modules that sit on the coil terminals of a contactor and cut the switching transient at the source. RC networks hold the peak to 3 x Uc, varistors to 2 x Uc, and diode assemblies remove the peak on DC coils. Voltage bands run from 24 to 48 V, 50 to 127 V, 110 to 240 V and 380 to 415 V AC, with 12 to 250 V DC on diodes. Each type adds a known release delay, which is stated here rather than left to be found on the machine.
Semiconductor and DC Fuses for Drive and Battery Protection aR fuse links that clear a fault before the module sees the let through energy, sized from 40 A to 2250 A. Square body and NH bodies carry the same 690 V AC rating, in four mounting styles for busbar and rail builds. DC ratings are quoted separately: 150 kA at 1000 V DC on the PSR range, 50 kA at 500 V DC on the stud fuse. Pre-arcing and clearing I2t sit on the same row, so a replacement is checked on energy rather than on amps.
Cam Switches and Changeover Switches for Panel Control Rotary cam switches stack contact stages on one shaft and close them in a fixed sequence as the handle turns. Thermal current runs 10 A on the S00 frame, 20 A on the S0 frame and 25 A on the larger S1 frame. Motor ratings are 3 kW, 7.5 kW and 11 kW at 380 to 440 V AC-23A, with 30, 45, 60 and 90 degree angles. Changeover switches add a 20 A mains transfer option with or without a centre off position.
PTC Thermistor Motor Protection Relays for Winding Temperature Relays that trip on the resistance of PTC sensors buried in the motor windings, not on current. Trip threshold sits at 2.7 to 3.1 kOhm and the reset threshold at 1.1 to 1.65 kOhm, so the contact cannot chatter. Supply is 24 V or 24 to 240 V AC DC on one part, with 1 CO, 1 NO plus 1 NC or 2 CO outputs. ATEX versions, non volatile trip memory and two sensor circuits are listed per part number.
Power Factor Correction Capacitors for Panel Compensation A compensation capacitor supplies the reactive current that a motor or a rectifier draws, so the panel does not take it from the supply. The range covers 12.5 to 33.1 kvar at 415, 440 and 525 V in three phase delta cans from 85 to 116 mm diameter. Each can has an overpressure disconnector that takes all three phases off the supply at end of life. Life is quoted at 180,000 hours for the gas filled series, with 500 times rated current inrush.
Non-Fused Switch Disconnectors for Panel and Machine Isolation A non-fused disconnector gives a visible break without a fuse, which is what a maintenance lock out or a local isolator needs. Eight bodies cover 16 to 100 A with AC-23A ratings from 7.5 to 37 kW at 400 V. Insulation voltage is 750 V and impulse withstand is 8 kV, with a conditional short circuit rating of 50 kA behind a fuse. The handle and shaft are ordered separately, so the operating position can be chosen on the panel.
Emergency Stop Devices and Enabling Switches for Machine Safety An emergency stop is a device with a mechanical latch, a positive opening contact and a shape that a hand finds without looking. The devices here cover 22 mm panel parts, a ready made station and three stage enabling switches for a teach pendant. Contacts are 1 NC on the basic parts and 1 NO plus 1 NC on the station types, all with positive opening. Sealing is IP66, IP67 and IP69K, and mechanical life reaches 300,000 operations.
Signal Isolators and 4-20 mA Converters for Panel Signals A signal isolator breaks the galvanic path between a field sensor and the control system, and converts the standard signal on the way through. The range covers single and dual channel parts in 6.2 and 12.5 mm bodies on 35 mm rail. Isolation is 3-way or 4-way with 1.5 to 2 kV test voltage and an accuracy of 0.1 percent of final value. HART signals pass through the current loop without being converted.
Motor Start and Run Capacitors for Single Phase Motors A single phase motor needs a capacitor to make a second phase, and the run and start jobs are two different parts. CBB60 run capacitors cover 1 to 60 uF at 250, 370, 440 and 450 VAC in a self healing film can. CD60 start capacitors cover the short time duty range up to 280 uF at 250 VAC in an aluminium can. Can diameter and height are given for each value, because the space on the motor bracket decides the order.
Braking Resistors for Variable Speed Drives A braking resistor turns the energy of a decelerating motor into heat, and the cycle decides its size rather than the drive rating. The range covers 5 to 100 ohm and 0.1 to 32 kW average power at 50 C in IP20 and IP23 enclosures. Light, medium and severe cycle tables are given for a 40 s and a 120 s period. Each part carries a thermal switch or is monitored by the drive at 120 C.
Line Reactors and Motor Chokes for Variable Speed Drives A reactor is the cheapest way to take the edge off a drive installation, on the supply side or on the motor side. Ten chokes cover 0.1 to 10 mH and 4 to 450 A in a three phase body that mounts beside the drive. Load side chokes limit dv/dt at the motor when the cable run is over 50 m. Every part is rated for 1.65 times its nominal current for 60 seconds.
NH Fuse Links and DIN Rail Fuse Bases NH fuse links are the fuse that a European panel is built around, and the size on the label decides the base, not the current. The gG range here covers 6 to 250 A across NH000, NH00, NH1 and NH2 with 120 kA breaking capacity at 500 V AC. Bases are rated 690 V AC and 440 V DC, with a 95 mm2 flat terminal and an M8 stud. Sizes are 21 mm for NH000 and 30 mm for NH00, NH1 and NH2, and the two are not interchangeable.
Surge Counters and SPD Monitoring Units Surge protection without a signal is a part nobody looks at until a board fails. Monitoring runs from one floating changeover contact up to a Modbus unit that reports part numbers. Counters record how many impulses passed, which is what turns a maintenance visit into a plan. All units mount on 35 mm rail, from one module wide up to a pre-wired interface for 40 arresters.
Industrial Plugs and Sockets for Machine Power Plugs, connectors and wall sockets to IEC 60309 for machines that are moved, serviced or swapped. Ratings run from 16 A to 63 A in 3, 4 and 5 pole versions, at 110, 230, 400 and 500 V. The clock position and the colour code the voltage, so a 400 V plug cannot enter a 230 V socket. IP44 covers indoor panels and IP67 covers washdown bays, with the cable range stated per part.
Timer Relays for Panel Control Sequences DIN rail timers that hold a sequence together when a PLC output is not available or not wanted. Seven functions cover on delay, interval, flasher, off delay with a control signal and true off delay. Contacts are 1 CO at 16 A on the multi function types and 8 A on the off delay family. Supply is 24 to 240 V AC or DC on one part, with six time ranges from 0.1 s to 24 h on the front.
DC Isolator Switches for PV and Battery Strings DC switch disconnectors for photovoltaic strings, combiners and battery racks, from 16 A up to 250 A. Rated voltage reaches 1000 V DC on the standard bodies and 1500 V DC on the wider frames, with poles connected in series to break the arc. Contacts are visible and the mechanism is quick make and quick break, which an AC switch does not provide. The short circuit rating and the utilisation category decide whether the switch suits a PV array or a battery with a high fault level.
Insulation Monitoring Devices for Unearthed Systems Insulation monitoring relays that watch an unearthed system and report a falling insulation resistance before a second fault makes contact. Measuring ranges run from 1 to 100 kOhm and 2 to 200 kOhm, with two separately adjustable alarm thresholds. Supply is 24 to 240 V AC or DC, and the measuring circuit takes the system voltage directly up to 400 V AC and 600 V DC. System leakage capacitance of 20 microfarad is the limit on these bodies, which is what decides the type on a drive fed system.
Fuse Switch Disconnectors for Panel Isolation NH fuse switch disconnectors that combine a load break switch and a fuse holder in one body for panel feeders. Ratings run from 100 A to 160 A at 690 V AC, in NH000 and NH00 fuse sizes, three or four pole. The AC-23 rating is the one that applies to a motor load, and it is well below the thermal current at 690 V on some types. Front operated versions need a handle and a shaft ordered with the switch, which is the usual missing line on a first order.
Direct-On-Line Motor Starters for Small Drives Direct-on-line starters for motors up to about 18.5 kW at 400 V, in enclosed IP65 housings or as open combinations for the panel. Each starter is a contactor plus a thermal overload relay, and the relay is a separate order in most families. Coil voltages follow a code: M7 is 220 V, P7 is 230 V, N7 is 415 V on the enclosed range. The overload setting is the motor full load current, not the starter rating, and that is the number that protects the winding.
DIN Rail kWh Meters for Panel Energy Monitoring DIN rail energy meters that put a kWh reading inside a control panel, from one module wide up to four modules. Direct connected types take the load current themselves up to 65 A or 100 A; larger feeds use a current transformer input. Accuracy is class B, which is one percent on active energy, with class 1 on the single phase ranges. Outputs cover a passive pulse, RS-485 Modbus RTU and M-Bus, and multi-tariff versions are listed separately.
Shunt Trip and Undervoltage Release Coils Trip coils that open a DIN rail breaker from a control signal, fitted to the side of the device in one or two modules. Shunt trips work on an applied voltage; undervoltage releases hold the breaker closed and drop it when the coil loses supply. Coil voltages run from 12 V DC up to 415 V AC, with 110 to 240 V AC as the common panel control values. The two functions are not interchangeable, and the trip window of an undervoltage release decides whether it suits an emergency off loop.
AC Axial Fans for Enclosure Cooling Mains powered axial fans for cabinets and machine enclosures, from 119 mm up to 172 mm frame size. Voltages cover 115 V and 230 V at 50 and 60 Hz, with shaded pole and capacitor induction motors. Airflow, noise and static pressure are listed together, because a fan chosen on flow alone stalls behind a filter. Ball bearing types carry L10 figures at 40 C and 55 C, which is what decides a replacement interval.
Residual Current Devices for Panel Feeders Residual current devices that compare the current going out on the phases with the current coming back on the neutral, and open when the difference passes the set level. Bodies cover two pole outgoing circuits and four pole feeder protection, at 25 to 63 A and 30, 100 or 300 mA. Detection types run from AC for resistive loads to A for pulsating DC and B for smooth DC from drives and chargers. Conditional short circuit ratings are 10 kA with the matching upstream fuse or breaker, so the feeder device and the backup device are chosen together.
Phase Failure and Voltage Monitoring Relays DIN rail relays that watch a three-phase supply and drop a contact when a phase is lost, the sequence is reversed or the voltage leaves its window. Families cover phase failure only, phase failure with asymmetry, and full over and undervoltage monitoring on one or two thresholds. Most types are powered from the measuring circuit, so no separate auxiliary supply is needed in the panel. Widths run from 17.5 mm for a single function to 35 mm where two independent output contacts are required.
Control Transformers for Panel Control Voltage Single phase control transformers that take a 230 V or 400 V supply and deliver 24 V, 115 V or 230 V to the control circuit. Ratings run from 25 VA to 2500 VA, with the input tapped for 230 V and 400 V on the same winding. The secondary is separated from the primary, so a control circuit is isolated from the mains and can be earthed on one side. Efficiency, dissipation and ambient rating are listed per rating, because the enclosure heat comes from this part.
Industrial Pushbuttons and Selector Switches for Panel Fronts 22 mm metal pushbuttons, selector switches and mushroom head emergency stop devices for equipment fronts. Contact blocks are 1 NO or 1 NC with a 10 A thermal rating and a 600 V insulation rating. The front reaches IP66, and IP69K on the selector switches and the multiple head pushbuttons. Spring return and stay put versions are listed separately, because the function follows the operator type.
DIN Rail Terminal Cross Connectors and Accessories Plug-in cross connectors that bridge two to ten DIN rail terminals in one row, without a wire between them. Each part is tied to a pitch, so the connector matches the terminal family rather than the row length. Rated 24 A and 800 V on the 5.2 mm range, with red and blue bodies to mark the two potentials. Cut to length on site or ordered in the exact position count, with the end plate and partition quoted alongside.
Brake Rectifiers and Motor Brake Modules Rectifier modules that feed a DC spring applied brake from the AC supply in the motor terminal box. Half wave types give 0.45 times the input voltage, bridge types 0.9 times, and bridge half wave types switch between the two. Bridge half wave versions overexcite the coil to release the brake fast, then hold it at the lower voltage. Input ranges cover 230 V, 400 V and 555 V mains, with output currents from 0.75 A to 3 A.
Soft Starters for Motor Starting Soft starters from 17 A to 250 A rated current, covering 7.5 kW to 132 kW motors at 400 V. Built-in bypass on the Altistart 22 range removes the heat of a running thyristor stack from the enclosure. Current limit, ramp up and ramp down are set on the front, with motor overload protection inside the device. Siemens SIRIUS 3RW40 sizes are listed alongside, because the panel may standardise on either family.
Cable Trays and Ladder Rack for Panel Feeds Wire mesh cable trays in three side heights and widths from 100 mm to 600 mm, supplied in 3 m lengths. Ladder rack in 100 mm side height with 300 mm to 600 mm widths, weighed per piece for support planning. Both families are listed with the wire or rung data that sets the load a support span can carry. Splice plates, supports and earthing continuity are quoted with the tray, not left to the installer.
Digital Panel Meters and Counters for Control Panels Panel meters that turn a DC signal into a readable number, in four input ranges from 200 mV to 200 V full scale. Totalisers with eight digits and a built-in battery that keep counting with the panel supply off. Preset counters with relay output and a 48 by 48 mm cut-out for machine cycles and batch counts. Every part is listed with its cut-out, supply and input type, because those three decide the fit.
Motor Protection Circuit Breakers for Panel Feeders Thermal magnetic motor protection circuit breakers from 0.10 A to 32 A in three families. Setting range and magnetic trip are listed per part number, because both decide whether the motor starts. One device provides the overload element, the short circuit trip and the isolation point. Mounting is on 35 mm rail, so the feeder occupies one column in the panel.
Thermal Overload Relays for Motor Protection Class 10 thermal overload relays from 0.10 A to 80 A in three contactor families. Setting ranges are listed per part number, because the range is what the motor current has to fall inside. Manual or automatic reset, trip indicator and a test button are standard on the frames shown. Each relay clips under its matching contactor, so the starter is ordered as one mechanical set.
Contactors and Reversing Contactors for Motor Loads Three-pole contactors from 7 A to 50 A in AC-3 at 400 V, covering 3 kW to 22 kW motors. Reversing versions come as a matched pair with mechanical interlock and wiring already fitted. Coil codes for 24 V DC, 24 V AC and 110 to 415 V AC are listed for each family. Overload relays clip under the same frame, so the starter is ordered as one set.
DIN Rail Power Supplies for Control Cabinets DIN rail supplies from 120 to 960 W in 12, 24 and 48 V versions. Universal 90 to 264 V AC input on the single phase families, 3-phase types for higher power. TS35/7.5 and TS35/15 mounting, with output adjustment and short circuit protection. Redundancy modules for a 24 V rail that must not drop on one supply failure.
Enclosure Document Pockets and Door Pockets Document pockets in A3 landscape, A4 portrait and A5 landscape, self adhesive on the door. Wiring plan pockets with a variable width, screwed to the door strip of a 400 to 800 mm door. Depth from 17 to 45 mm, so a wiring diagram and a test sheet fit together. Clear front, so the drawing is read without opening the cabinet.