Contact Us

AC Axial Fans for Enclosure Cooling

Mains powered axial fans for cabinets and machine enclosures, from 119 mm up to 172 mm frame size. Voltages cover 115 V and 230 V at 50 and 60 Hz, with shaded pole and capacitor induction motors. Airflow, noise and static pressure are listed together, because a fan chosen on flow alone stalls behind a filter. Ball bearing types carry L10 figures at 40 C and 55 C, which is what decides a replacement interval.
quote now

Product Specifications

Product Overview

An AC axial fan is the simplest way to move air through a cabinet: no driver, no DC rail, no polarity. Line voltage goes to two leads, the motor turns at a speed set by the supply frequency, and the airflow is fixed by the impeller geometry. That is why mains fans are still the default on machine tools, power supplies and panel enclosures where a 24 V rail may not be present or may not carry the current.

The number that decides the purchase is not the free air flow printed on the box. A fan pushing through a filter mat, a louvre or a narrow duct works against static pressure, and the operating point moves down the curve. Two fans with the same free air figure can end at very different flows once a filter is in front of them, which is why every row in the table below carries airflow, noise and maximum static pressure together.

The second decision is the motor and bearing. Shaded pole motors are cheap and simple but less efficient, and they are the normal choice below about 30 W. Capacitor induction motors appear on the larger 172 mm frames where the extra torque is needed to hold speed against pressure. Sleeve bearings are quiet when new and lose life at high ambient; ball bearings cost more and are the only sensible choice on a fan that runs continuously at 55 C.

Key Specifications

FamilyFrame sizeVoltagePowerAirflowNoiseBearing
ebm-papst 4650N119 x 119 x 38 mm230 V, 50 Hz19 W160 m3/h46 dB(A)sleeve, L10 37,500 h at 40 C
Orion OA109AP-22-1TB120 x 120 x 38.5 mm230 V, 50/60 Hz21 / 20 W90 / 105 cfm48 dB(A)dual ball
Orion OA109AP-22-2TB120 x 120 x 38.5 mm230 V, 50/60 Hz14 / 13 W82 / 85 cfm43 dB(A)dual ball
Orion OA109AP-22-3TB120 x 120 x 38.5 mm230 V, 50/60 Hz12 / 9 W58 / 60 cfm32 dB(A)dual ball
Orion OA109AP-11-1TB120 x 120 x 38.5 mm115 V, 50/60 Hz21 / 20 W90 / 105 cfm48 dB(A)dual ball
Orion OA172AP-22-1TB172 x 51 mm230 V, 50/60 Hz26 / 35 W195 / 235 cfm53 dB(A)dual ball, capacitor motor
Orion OA172SAP-22-1TB172 x 150 x 51 mm230 V, 50/60 Hzon request198 / 235 cfm50.3 / 52.1 dB(A)dual ball

Included Models and Order Codes

Model codes carry the voltage and the speed grade. On Orion the middle pair is the voltage, 11 for 115 V and 22 for 230 V, and the third digit is the speed grade: 1 is the fastest and loudest, 3 the slowest and quietest, on the same frame and the same mounting holes. The last letters are the termination, T for terminal and W for wire leads. On ebm-papst the type number is fixed per frame and voltage, so 4650N is the 119 mm 230 V version and there is no speed grade to choose.

Part numberFrameVoltagePowerAirflow at 50/60 HzStatic pressureNoise
4650N119 x 119 x 38 mm230 V19 W160 m3/h at 50 Hz80 Pa at 0.1 m3/s46 dB(A)
OA109AP-11-1TB120 x 120 x 38.5 mm115 V21 / 20 W90 / 105 cfm0.25 / 0.22 in H2O48 dB(A)
OA109AP-11-2TB120 x 120 x 38.5 mm115 V14 / 13 W82 / 85 cfm0.17 / 0.12 in H2O43 dB(A)
OA109AP-22-1TB120 x 120 x 38.5 mm230 V21 / 20 W90 / 105 cfm0.25 / 0.22 in H2O48 dB(A)
OA109AP-22-2TB120 x 120 x 38.5 mm230 V14 / 13 W82 / 85 cfm0.17 / 0.12 in H2O43 dB(A)
OA109AP-22-3TB120 x 120 x 38.5 mm230 V12 / 9 W58 / 60 cfm0.11 / 0.09 in H2O32 dB(A)
OA172AP-22-1TB172 x 51 mm230 V26 / 35 W195 / 235 cfm0.57 / 0.70 in H2O53 dB(A)
OA172AP-22-2TB172 x 51 mm230 V22 / 20 W175 / 170 cfm0.49 / 0.47 in H2O42 dB(A)
OA172SAP-22-1TB172 x 150 x 51 mm230 Von request198 / 235 cfm0.56 / 0.70 in H2O50.3 / 52.1 dB(A)

Choosing Between Speed Grades on One Frame

The three OA109AP speed grades share a frame, a cut-out and a fixing hole pattern, and differ only in the winding and the impeller pitch. The table shows what that choice costs in flow, noise and current, which is the trade a panel builder makes against a filter and a thermostat setting.

Speed gradeAirflow at 60 HzNoisePower at 60 HzAirflow per wattWhere it fits
grade 1 (1TB)105 cfm48 dB(A)20 W5.3 cfm/Wfilter in front, high heat load, noise accepted
grade 2 (2TB)85 cfm43 dB(A)13 W6.5 cfm/Wmost cabinets, balanced flow and noise
grade 3 (3TB)60 cfm32 dB(A)9 W6.7 cfm/Woffice side of a wall, low heat load

Key Features

Airflow, pressure and noise in one row – the operating point behind a filter mat can be read off the table instead of assumed from the free air figure, which is where most undersized fan choices start.

230 V and 115 V on the same frame – the two voltage versions share the cut-out and the fixing centres, so a machine exported to a 115 V market does not need a new panel opening.

Dual ball bearings on the Orion range – L10 of 50,000 h at 55 C on the 120 mm frame and 100,000 h at 40 C on the 172 mm frame, which is the figure that sets the service interval.

Impedance protected motors – the shaded pole types are protected against overload by their own impedance, so a stalled impeller does not take the winding with it on a short circuit.

IP55 rated motor on the metal range – the winding and the lead exit are sealed, which matters where the fan is washed down with the rest of the machine.

Capacitor induction on 172 mm frames – the larger frame holds speed against a dirty filter instead of dropping away as the pressure rises, at the cost of a starting capacitor in the housing.

Applications

The same fan is bought for three different jobs, and each sets a different priority between flow, noise and life.

Cabinet cooling with a filter fan – an AC fan behind a standard filter mat on the intake, with the airflow matched to the heat load and the filter resistance rather than to the fan free air figure.

Machine enclosure exhaust – a top mounted fan pulling hot air out of a spindle or drive enclosure, where the static pressure from a louvre is low and noise matters because the operator stands next to it.

Power supply and charger racks – continuous running at 40 to 55 C ambient, where the ball bearing life figure and the impedance protected motor decide the replacement cycle more than the flow does.

The fan is quoted with the control board that switches it, so the SUPERB PCBA and the SUPERB PCB are checked against the same cabinet list and the thermostat contact rating agrees with the fan current.

Sourcing and Cross-Reference

Size the fan from the heat load, not from the old part. A cabinet needs roughly the airflow that removes the watts inside it at the permitted temperature rise, and that figure changes when a filter is added or a drive is upgraded. Replacing a fan with the same frame and the same flow is only correct if the heat load did not move.

Decide the bearing on run hours. A sleeve bearing fan in a cabinet that runs one shift is fine and quieter. The same fan on a machine that runs 24 hours at 50 C ambient will need replacing inside two years, and the ball bearing version costs less over that period than the downtime.

Keep the cut-out and the fixing centres when substituting. The 120 mm frames share a 104.8 mm fixing square, so a different brand still fits the same opening, but the depth and the lead exit differ and a fan with a terminal block needs clearance inside the door. See lead time and availability for the current position, and obsolete part cross reference when the original type has been discontinued.

The SUPERB Assembly team keeps the fan leads on their own terminal pair and fuses the 230 V side, because a fan sharing a control terminal with a sensor is the usual source of a noise complaint.

Q: Can you supply the fan with the filter, the guard and the thermostat as one matched set for a cabinet build?

A: Yes. Send the cabinet heat load, the ambient temperature and the cut-out size, and the SUPERB Tech team returns the frame, the voltage and the speed grade that hold the temperature inside the limit.

Why Panel Builders Buy AC Axial Fans From SUPERB

  1. Flow and pressure together: every row states the static pressure at the same point as the airflow, so the fan is chosen against a filter rather than in free air.
  2. Speed grades on one frame: the quiet and the powerful version of the same 120 mm fan are quoted side by side, which keeps the cut-out unchanged when the heat load moves.
  3. Bearing life stated: L10 hours at a named ambient temperature are listed, so the service interval is a number rather than a guess.
  4. Voltage variants matched: 115 V and 230 V types are held against the same frame and fixing centres, which matters for machines built for more than one market.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: DC Axial Fans for Enclosure Cooling, Fan Guards and Filter Screens for Enclosure Cooling, Filter Fan Units and Exhaust Filters for Enclosure Cooling, Enclosure Air Conditioners for Sealed Cabinet Cooling, Enclosure Heat Exchangers for Dusty and Sealed Sites.