Plug-in cross connectors that bridge two to ten DIN rail terminals in one row, without a wire between them. Each part is tied to a pitch, so the connector matches the terminal family rather than the row length. Rated 24 A and 800 V on the 5.2 mm range, with red and blue bodies to mark the two potentials. Cut to length on site or ordered in the exact position count, with the end plate and partition quoted alongside.
quote now

Product Specifications

Product Overview

A cross connector turns a row of terminals into one node. Instead of a wire looped from terminal to terminal, a comb shaped copper bridge is pushed into the spring or screw slot and the row becomes a busbar. The saving is space and time, and the risk is a bridge that does not fit the pitch of the terminal it is pushed into.

Pitch is the number that decides compatibility. A 5.2 mm bridge fits a 5.2 mm terminal row, and the same row in a 6.2 mm terminal needs a different part. The two look identical in a photograph and are not interchangeable: the pins are spaced 5.2 mm apart on one and 6.2 mm on the other, and forcing the wrong one spreads the contact spring and leaves a high resistance joint.

The second decision is how many positions the bridge covers. A two position bridge is used for a pair of feed terminals, a ten position bridge for a full row. Where the exact count is not available, a longer bridge is cut with side cutters, and the cut end has to be deburred before it goes in. The current rating belongs to the bridge and to the terminal together, so the lower of the two figures is the one that counts.

Key Specifications

FamilyPitchPositionsRated currentBody materialColour
Phoenix FBS 2-5 to FBS 10-55.2 mm2 to 1024 Acopper, PA insulationred RAL 3001
Phoenix FBS 2-5 BU5.2 mm224 Acopper, PA insulationblue RAL 5015
Phoenix FBS 2-66.2 mm2on requestcopper, PA insulationred
Phoenix FBS 2-88.2 mm2on requestcopper, PA insulationred
Phoenix FBS 2-1212.2 mm2on requestcopper, PA insulationred

Included Models and Order Codes

The code is positions first, then pitch: FBS 10-5 bridges ten terminals on a 5.2 mm row. Length grows with the position count, so a ten position bridge is 50.6 mm wide against 23 mm for the two position part, and the depth stays at 3 mm across the range. The rated current of 24 A applies to the bridge itself, and the maker notes that the figure for a bridged row is taken from the accessory data of the terminal being used, because the terminal body sets the limit.

Part numberPositionsPitchRated currentColourBody
3030161, FBS 2-525.2 mm24 Aredshort body
3030174, FBS 3-535.2 mm24 Aredshort body
3030187, FBS 4-545.2 mm24 Aredshort body
3030190, FBS 5-555.2 mm24 Aredshort body
3030213, FBS 10-5105.2 mm24 Aredwide body, 50.6 mm
3036877, FBS 2-5 BU25.2 mm24 Ablueshort body
3030336, FBS 2-626.2 mmon requestredshort body
3030284, FBS 2-828.2 mmon requestredshort body
3005950, FBS 2-12212.2 mmon requestredshort body

Key Features

One bridge replaces a wire loop – the row becomes a single node in one push, with no terminal to terminal wire to strip and torque.

Pitch marked in the code – the last digit is the pitch in millimetres, so a 5.2 mm terminal and a 6.2 mm terminal cannot be confused at the order stage.

Two to ten positions – short bridges for a pair of feed terminals, long bridges for a full row, with the same 3 mm depth.

Red and blue bodies – the two colours mark the two potentials on a row that carries both, which is what a service engineer reads first.

Copper conductor, PA body – the comb is copper for the current and the insulation is PA rated to UL 94 V0, so the bridge does not become the weak point in a fault.

Cut to length – a longer bridge is shortened with side cutters, which covers the row lengths that are not stocked as a standard part.

Applications

A bridged row is used wherever several terminals carry the same potential. Three cases cover most panel work.

Sensor supply distribution – one 24 V feed bridged across ten terminals, so each sensor has its own terminal and the row needs one wire from the supply.

Earth and neutral rows – a full row bridged with the blue body for neutral and the green yellow terminal for earth, kept separate from the live bridges.

Motor terminal grouping – two position bridges on pairs of terminals where a cable lands and leaves, which keeps the ferrule count down without a wire link.

The bridged row is quoted with the board that feeds it, so the SUPERB PCBA and the SUPERB PCB are checked for the same 24 V distribution and the terminal count matches the connector positions.

Sourcing and Cross-Reference

Read the pitch off the terminal, not off the drawing. The terminal data sheet gives the pitch in millimetres and the accessory table lists the bridges that fit that body. Terminal rows that look the same are often 5.2 mm and 6.2 mm, and a bridge pushed into the wrong pitch damages the contact spring in a way that shows up as a warm terminal months later.

Take the current from the terminal, not from the bridge. The bridge is rated 24 A, and the row it feeds may be rated lower. Where the row carries a motor circuit, the bridged current is the sum of the outgoing circuits, and that sum is what the terminal body has to carry.

Order the position count you need where it exists. Cutting a ten position bridge works, and each cut leaves a pin that has to be deburred and a length that has to be checked against the row. On a production panel the exact count is faster and leaves no swarf in the row.

Bridges are small parts that are often left off the first order and hold up the wiring stage. See lead time and availability for the position today, and shortage recovery when a row cannot be bridged from stock.

The SUPERB Assembly team fits the bridge before the end plate, because an end plate pushed on first leaves no room for the comb to seat in the last terminal.

Q: Can you supply the cross connectors with the terminal blocks, in the position count each row actually uses?

A: Yes. Send the terminal part number used on the row and the number of terminals to be bridged, and the SUPERB Tech team returns the bridge code, the colour and the current the row can carry.

Why Panel Builders Buy Cross Connectors From SUPERB

  1. Terminal and bridge quoted as a pair: the pitch is checked against the terminal family, so the bridge cannot arrive one size off.
  2. Position count per row: the exact count is taken from the wiring schedule instead of a ten position bridge cut on site.
  3. Current checked on the terminal: the bridge rating and the terminal rating are compared, and the lower figure goes on the quotation.
  4. Colour used as a marker: red and blue bodies are quoted together where a row carries two potentials, which reduces the chance of a bridge across the wrong pair.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: DIN Rail Terminal Blocks for Control Panel Wiring, DIN Rail End Stops and Terminal Partition Plates, Wire Ferrules and Crimp Sleeves for Terminal Blocks, Steel and Aluminium DIN Rails for Control Cabinets, Jumper Links and Shunt Headers for Board Configuration.