Industrial Pushbuttons and Selector Switches for Panel Fronts
Product Specifications
Product Overview
A 22 mm pushbutton is two parts that are ordered as one: an operator head that fits the door and a contact block that makes the circuit. A complete reference such as XB4BA31 is a head with its block already fitted, and the same head is also sold as a sub assembly for panels that keep the blocks in stock.
The contact composition is what the circuit needs, and the colour is what the operator reads. Green with 1 NO is a start, red with 1 NC is a stop, and a black selector with two positions stays where it is put. A spring return pushbutton comes back on its own, and that difference is the whole function of a start button against a maintained switch.
The mushroom head emergency stop is a separate case. It latches mechanically and is released by turning or by key, and the contact is 1 NC or 2 NC depending on whether the circuit has one or two channels. The head diameter is 40 mm, which is the size that a hand finds without looking.
Key Specifications
| Range | Mounting | Contacts | Thermal current | Insulation voltage | Protection |
|---|---|---|---|---|---|
| XB4 metal pushbuttons | 22 mm cut-out, chromium plated bezel | 1 NO or 1 NC | 10 A | 600 V, pollution degree 3 | IP66, IP69K, NEMA 4X and 13 |
| XB4 selector switches | 22 mm cut-out, chromium plated bezel | 1 NO, or 2 NO | 10 A | 600 V, pollution degree 3 | IP66, IP67, IP69K |
| XB4 emergency stop heads | 22 mm cut-out, 40 mm mushroom | 1 NC or 2 NC | 10 A | 600 V, pollution degree 3 | IP66, NEMA 4X and 13 |
| XB5 plastic pushbuttons | 22 mm cut-out, plastic bezel | 1 NO or 1 NC | 10 A | 600 V | IP66 on the front |
Included Models and Order Codes
The reference is built from the head, the colour and the contact block, so a change of one letter changes the function. XB4BA21 is a black flush head with 1 NO, XB4BA31 is the same head in green, and XB4BA42 is a red head with 1 NC. The P in XB4BP21 marks a projecting head that is easier to find by touch, and the BD codes are selector switches, with the last digits setting two or three positions. Terminals take up to two 1.5 mm squared conductors with a ferrule, and the tightening torque is 0.8 to 1.2 Nm.
| Part number | Operator | Colour | Contacts | Action | Typical use |
|---|---|---|---|---|---|
| XB4BA21 | flush pushbutton | black | 1 NO | spring return | cycle start, general function |
| XB4BA31 | flush pushbutton | green | 1 NO | spring return | start, reset after a stop |
| XB4BA42 | flush pushbutton | red | 1 NC | spring return | stop, fault acknowledge |
| XB4BP21 | projecting pushbutton | black | 1 NO | spring return | function found without looking |
| XB4BP42 | projecting pushbutton | red | 1 NC | spring return | stop on a guarded panel |
| XB4BD21 | selector switch, 2 positions at 90 degrees | black | 1 NO | stay put | manual and automatic selection |
| XB4BD33 | selector switch, 3 positions at 45 degrees | black | 2 NO | stay put | three mode selection |
| XB4BS8442 | mushroom head, 40 mm, turn to release | red | 1 NC | latching | emergency stop, single channel |
| XB4BS8444 | mushroom head, 40 mm, turn to release | red | 2 NC | latching | emergency stop, dual channel |
Travel, Torque and Life of the Operator
The electrical data is in the contact block; the mechanical data is in the head, and it decides how the button feels and how long it lasts. The figures below are from the maker data for the 22 mm metal range, and they matter on a machine that is cycled by hand all day: a spring return head rated at five million operations is not the part for a push push function that is used ten times a shift.
| Characteristic | Value | Note |
|---|---|---|
| Travel to change the NC state | 1.5 mm | contact opens before the NO closes |
| Travel to change the NO state | 2.6 mm | total travel 4.3 mm |
| Operating torque, selector switch | 0.14 Nm | NO contact changing state |
| Mechanical life, spring return pushbutton | 5 million operations | at rated travel |
| Mechanical life, selector switch | 1 million operations | stay put positions |
| Mechanical life, push push | 0.5 million operations | release by pressing again |
| Tightening torque, terminals | 0.8 to 1.2 Nm | two 1.5 mm squared conductors with ferrule |
| Short circuit protection | 10 A gG fuse | per EN 60947-5-1 |
Key Features
One 22 mm cut-out for the whole range – pushbuttons, selectors, emergency stop heads and pilot lights share the same hole, so a panel layout can change without re-punching.
Contact blocks changed without the head – the block unclips from the head, which turns a 1 NO start into a 1 NC stop with the operator still in the door.
IP66 front as standard – the seal is part of the head, so a wash down front does not need a separate boot.
Emergency stop with a 40 mm head – the latching mushroom head is released by turning, which is the release an operator reaches for without instruction.
Slow break contacts – the contact opens at a defined point in the travel, which is what a logic input needs to see a clean edge.
Screw clamp terminals – two conductors per terminal with a ferrule, which allows a loop through to the next device in the same column.
Applications
Panel fronts repeat the same few functions. Three patterns cover most machines.
Machine start and stop column – a green 1 NO start and a red 1 NC stop, both spring return, wired through the safety relay so the stop is a category 0.
Manual and automatic selection – a two position stay put selector with 1 NO, so the mode survives a power cycle and the operator sees it on the front.
Emergency stop at each operator position – a latching 40 mm mushroom with 1 NC or 2 NC depending on the channel count, released by turning the head.
The front is quoted with the board behind it, so the SUPERB PCBA and the SUPERB PCB are checked for the input polarity and the lamp voltage of each button.
Sourcing and Cross-Reference
Choose the function before the colour. A start that must not latch needs a spring return head, and a mode that must survive a power cycle needs a stay put selector. Ordering a spring return selector for a mode switch is a common mistake, and it shows up as a machine that starts in the wrong mode after a reset.
Count the contacts against the input card. A 1 NC stop wired into a single channel safety relay is one contact, and a dual channel circuit needs two. The mushroom head comes with 1 NC or 2 NC in the same body, so the second contact is a reference change rather than a second device.
Keep the panel cut-out and the bezel material consistent across the front. Metal bezels on a plastic enclosure look different after a year, and the same 22 mm hole takes either, so the choice is made once for the whole front rather than per button.
Lead time follows the head colour and the contact block rather than the operator type. See lead time and availability for the position today, and shortage recovery when a front has to be completed from stock.
The SUPERB Assembly team lands the NC stop contact on a separate terminal pair, because a shared return turns a two channel circuit into a single channel one.
Q: Can you supply the full front set, with the contact blocks and the emergency stop heads matched to our channel count?
A: Yes. Send the front layout with the function of each position, the channel count of the safety circuit and the lamp voltage, and the SUPERB Tech team returns the references and the contact blocks.
Why Builders Buy Panel Pushbuttons From SUPERB
- Function and contact checked together: the operator action and the contact composition are compared with the circuit, so a start button does not arrive as a maintained switch.
- Complete references and sub assemblies: both the complete part and the head plus block are quoted, which suits a workshop that keeps blocks in stock.
- Emergency stop channel count: 1 NC and 2 NC heads are listed against the same 40 mm operator, so the safety relay input is matched at order time.
- Sealing stated: IP66 and IP69K are in the table per family, which decides whether the front can be washed down.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Rocker and Toggle Switches for Equipment Panels, Tactile and Slide Switches for Front Panel Control, Signal Towers and Stack Lights for Machine Status, Safety Relay Modules for Guard Monitoring, Enclosure LED Lamps and Door Switches.