Emergency Stop Devices and Enabling Switches for Machine Safety
Product Specifications
Product Overview
An emergency stop has to do three things at once. It has to be reachable without looking, so the actuator is a mushroom head at least 40 mm across in a colour that stands out. It has to stay operated once it is pressed, so the device latches mechanically and needs a deliberate release, either a twist or a pull. And it has to open the contact even if the contacts weld, which is what positive opening means: the actuator pushes the contact apart with a solid part rather than relying on a spring.
The contact arrangement matters for the safety circuit. A single NC contact is enough for a simple machine where the stop drops a contactor. A part with one NC and one NO is used where the NC goes to the safety relay and the NO is used for signalling or for a second channel, and the two contacts must not share a common terminal. The station version puts the device in a yellow enclosure with a lid, which is what a machine without a door uses.
Enabling switches are the other half of the problem. A teach pendant has to let an operator move the machine while the guard is open, and it does that with a three stage switch: released is safe, the middle position enables motion, and pressing past the middle disables it again. The third stage is the one that protects an operator who grips the switch in a shock reaction, and it is the reason a two position switch is not acceptable for this job.
Key Specifications
| Parameter | Value | Note |
|---|---|---|
| Actuator | red mushroom head, 40 mm diameter | unmarked head on the panel parts |
| Mounting | 22 mm panel cut out, or a ready made station | 22.5 mm finished hole recommended |
| Release | turn to release, or pull to release | the part latches mechanically until released |
| Contact arrangement | 1 NC on the base parts, 1 NO plus 1 NC on the station part | positive opening on the NC |
| Contact type | slow break, positive opening to IEC 60947-5-1 | the NC opens by a solid push, not a spring |
| Thermal current | 10 A | conventional thermal current |
| Utilisation category | 3 A at 240 V AC in AC-15, 0.27 A at 250 V DC in DC-13 | check the DC figure before switching a coil |
| Mechanical life | 300,000 operations | on the 22 mm metal part |
| Sealing | IP66, IP67, IP69 and IP69K | NEMA 4, 4X and 13 on the same part |
| Operating temperature | -40 C to +70 C | storage from -50 C |
| Terminals | screw clamp, 1 x 0.22 mm2 to 2 x 1.5 mm2 | shake proof terminal screws |
| Standards | IEC 60947-5-1, ISO 13850, IEC 60204-1 | stop function and machine electrical equipment |
| Enabling switch stages | 3 stages, off, on, off | release or full press both disable |
| Enabling switch contact | 1 signal contact, 125 V AC at 0.3 A or 30 V DC at 0.7 A | B10d 100,000 operations |
| Enabling switch sealing | IP65 at the front | 0 C to +50 C operating |
Included Models and Order Codes
The part number says what is in the box. On the 22 mm range the second group marks the shape, a B is a mushroom head, and AS marks a plastic part with two contacts. XALK is a complete station rather than a device, and the Pilz number 401 11x is a three stage enabling switch with the cable type in the last letter.
| Part number | Type | Contacts | Release | Sealing | Note |
|---|---|---|---|---|---|
| XB4BS542 | 22 mm emergency stop, metal bezel | 1 NC | turn to release | IP66, IP67, IP69K | 300,000 operations, slow break contact |
| XB5AS8445 | 22 mm emergency stop, plastic | 1 NO plus 1 NC | turn to release | IP66, IP67, IP69, IP69K | two contacts for a safety relay and a signal |
| XALK178 | complete station, yellow lid | 1 NC | turn to release | IP66, IP67, IP69K | device in an enclosure for a machine without a door |
| PIT en1.0p-5m-s | 3 stage enabling switch | 1 signal contact | spring return through 3 stages | IP65 | M12 5 pin angled connector, 5 m cable |
| PIT en1.0a-5m-s | 3 stage enabling switch | 1 signal contact | spring return through 3 stages | IP65 | 5 m straight cable, open end |
| PIT en1.1a-5m-s | 3 stage enabling switch | 1 signal contact | spring return through 3 stages | IP65 | 5 m coiled cable, open end |
What the Safety Circuit Needs From the Device
The device is one link in a circuit, and the circuit decides which contact arrangement is acceptable. The table below is what each element has to provide, in the terms of the machine safety standards.
| Element | Requirement | Why it matters |
|---|---|---|
| Stop function | a single action, latching, category 0 or 1 stop | ISO 13850, the machine must not restart on release |
| NC contact | positive opening to IEC 60947-5-1 annex K | a welded contact still opens mechanically |
| Second channel | a separate NC on another contact block | two channel wiring for a higher category |
| NO contact | signalling only, never the safety path | an NO can fail closed and hide a stop |
| Reset | manual, at the device, no automatic restart | twist or pull release, then a separate start |
| Enabling switch | 3 stage, middle position only enables | release or full press disables, protects a shocked operator |
| Sealing | at least IP65 on a wash down machine | water in the contact block shows as a stuck stop |
Key Features
Positive opening contact – the NC is pushed apart by a solid part of the actuator, so a welded contact still opens when the head is pressed.
Mechanical latch with twist release – the device stays operated until someone deliberately releases it, which is what stops a machine restarting when a hand comes off the button.
One NO and one NC on the station part – the two contacts are separate, so the NC can feed a safety relay while the NO drives a lamp or a PLC input.
IP69K sealing – a wash down machine sprays the panel at pressure and temperature, and the seal keeps water out of the contact block.
300,000 mechanical operations – the life figure is quoted on the metal part, which is what a machine that is stopped every cycle is checked against.
Three stage enabling – the middle position enables motion, and both release and a full press disable it, which is the behaviour a teach pendant needs.
Applications
These devices are bought by the machine and the way an operator reaches it, and three cases cover most of the requests.
Machine doors and access panels – a 22 mm device in the door frame puts the stop where the operator already reaches, and the twist release means the door can be opened again without a tool.
Machines without an enclosure – a station with a yellow lid carries the device and its cable entry in one part, which is what a conveyor or a stand alone machine uses.
Teach pendants and setup mode – a three stage enabling switch lets an operator jog the machine with the guard open, and the third stage stops the motion if the hand grips in a shock reaction.
The stop circuit and the board that reads it are quoted together, so the SUPERB PCBA and the SUPERB PCB are checked on the same terminal list and the second channel is not left unconnected.
Sourcing and Cross-Reference
Match the contact arrangement to the safety circuit, not to the old device. A single NC part replaces a single NC part, and a two contact part is only useful if the panel has two channels wired for it. Fitting a 1 NO plus 1 NC device where only one NC was used leaves the second contact unconnected and the safety category unchanged.
Check the DC rating before switching a coil. The AC-15 figure of 3 A at 240 V AC is the one on the label, while the same contact is rated 0.27 A at 250 V DC, and a 24 V DC brake or a contactor coil can exceed that. Where the load is DC and inductive, an interposing relay is the cheaper answer than a larger device.
Devices and stations are stock items in the common formats, and the enabling switches follow a cable length. Where a format is short, see lead time and availability, and cross reference when a device on the drawing has been discontinued.
The SUPERB Assembly team keeps the NC pair on its own terminals and labels the NO as signalling only, because a shared terminal is where a two channel circuit quietly becomes one channel.
Q: Can you supply the stop device, the station and the enabling switch for one machine, with the contact arrangement matched to the safety relay?
A: Yes. Send the safety relay, the number of channels and the sealing the machine needs, and the SUPERB Tech team returns the device, the station and the enabling switch that fit.
Why Machine Builders Buy Stop Devices From SUPERB
- Contact arrangement on the row: 1 NC and 1 NO plus 1 NC are separated, so the device is bought for the circuit rather than for the picture.
- Positive opening stated: the mechanical action is written with the part, which is what a safety assessment asks for.
- AC and DC ratings together: the AC-15 and DC-13 figures sit side by side, so a DC coil load is not hidden behind an AC rating.
- Sealing and temperature: IP69K and the operating range are listed, which decides whether the device survives a wash down line.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Industrial Pushbuttons and Selector Switches for Panel Fronts, Safety Relay Modules for Guard Monitoring, Door Interlock Switches for Safety Circuits, Mechanical Limit Switches for Position Sensing, Signal Towers and Stack Lights for Machine Status.