Contact Us
  • Home
  • COMPONENTS
  • Emergency Stop Devices and Enabling Switches for Machine Safety

Emergency Stop Devices and Enabling Switches for Machine Safety

An emergency stop is a device with a mechanical latch, a positive opening contact and a shape that a hand finds without looking. The devices here cover 22 mm panel parts, a ready made station and three stage enabling switches for a teach pendant. Contacts are 1 NC on the basic parts and 1 NO plus 1 NC on the station types, all with positive opening. Sealing is IP66, IP67 and IP69K, and mechanical life reaches 300,000 operations.
quote now

Product Specifications

Product Overview

An emergency stop has to do three things at once. It has to be reachable without looking, so the actuator is a mushroom head at least 40 mm across in a colour that stands out. It has to stay operated once it is pressed, so the device latches mechanically and needs a deliberate release, either a twist or a pull. And it has to open the contact even if the contacts weld, which is what positive opening means: the actuator pushes the contact apart with a solid part rather than relying on a spring.

The contact arrangement matters for the safety circuit. A single NC contact is enough for a simple machine where the stop drops a contactor. A part with one NC and one NO is used where the NC goes to the safety relay and the NO is used for signalling or for a second channel, and the two contacts must not share a common terminal. The station version puts the device in a yellow enclosure with a lid, which is what a machine without a door uses.

Enabling switches are the other half of the problem. A teach pendant has to let an operator move the machine while the guard is open, and it does that with a three stage switch: released is safe, the middle position enables motion, and pressing past the middle disables it again. The third stage is the one that protects an operator who grips the switch in a shock reaction, and it is the reason a two position switch is not acceptable for this job.

Key Specifications

ParameterValueNote
Actuatorred mushroom head, 40 mm diameterunmarked head on the panel parts
Mounting22 mm panel cut out, or a ready made station22.5 mm finished hole recommended
Releaseturn to release, or pull to releasethe part latches mechanically until released
Contact arrangement1 NC on the base parts, 1 NO plus 1 NC on the station partpositive opening on the NC
Contact typeslow break, positive opening to IEC 60947-5-1the NC opens by a solid push, not a spring
Thermal current10 Aconventional thermal current
Utilisation category3 A at 240 V AC in AC-15, 0.27 A at 250 V DC in DC-13check the DC figure before switching a coil
Mechanical life300,000 operationson the 22 mm metal part
SealingIP66, IP67, IP69 and IP69KNEMA 4, 4X and 13 on the same part
Operating temperature-40 C to +70 Cstorage from -50 C
Terminalsscrew clamp, 1 x 0.22 mm2 to 2 x 1.5 mm2shake proof terminal screws
StandardsIEC 60947-5-1, ISO 13850, IEC 60204-1stop function and machine electrical equipment
Enabling switch stages3 stages, off, on, offrelease or full press both disable
Enabling switch contact1 signal contact, 125 V AC at 0.3 A or 30 V DC at 0.7 AB10d 100,000 operations
Enabling switch sealingIP65 at the front0 C to +50 C operating

Included Models and Order Codes

The part number says what is in the box. On the 22 mm range the second group marks the shape, a B is a mushroom head, and AS marks a plastic part with two contacts. XALK is a complete station rather than a device, and the Pilz number 401 11x is a three stage enabling switch with the cable type in the last letter.

Part numberTypeContactsReleaseSealingNote
XB4BS54222 mm emergency stop, metal bezel1 NCturn to releaseIP66, IP67, IP69K300,000 operations, slow break contact
XB5AS844522 mm emergency stop, plastic1 NO plus 1 NCturn to releaseIP66, IP67, IP69, IP69Ktwo contacts for a safety relay and a signal
XALK178complete station, yellow lid1 NCturn to releaseIP66, IP67, IP69Kdevice in an enclosure for a machine without a door
PIT en1.0p-5m-s3 stage enabling switch1 signal contactspring return through 3 stagesIP65M12 5 pin angled connector, 5 m cable
PIT en1.0a-5m-s3 stage enabling switch1 signal contactspring return through 3 stagesIP655 m straight cable, open end
PIT en1.1a-5m-s3 stage enabling switch1 signal contactspring return through 3 stagesIP655 m coiled cable, open end

What the Safety Circuit Needs From the Device

The device is one link in a circuit, and the circuit decides which contact arrangement is acceptable. The table below is what each element has to provide, in the terms of the machine safety standards.

ElementRequirementWhy it matters
Stop functiona single action, latching, category 0 or 1 stopISO 13850, the machine must not restart on release
NC contactpositive opening to IEC 60947-5-1 annex Ka welded contact still opens mechanically
Second channela separate NC on another contact blocktwo channel wiring for a higher category
NO contactsignalling only, never the safety pathan NO can fail closed and hide a stop
Resetmanual, at the device, no automatic restarttwist or pull release, then a separate start
Enabling switch3 stage, middle position only enablesrelease or full press disables, protects a shocked operator
Sealingat least IP65 on a wash down machinewater in the contact block shows as a stuck stop

Key Features

Positive opening contact – the NC is pushed apart by a solid part of the actuator, so a welded contact still opens when the head is pressed.

Mechanical latch with twist release – the device stays operated until someone deliberately releases it, which is what stops a machine restarting when a hand comes off the button.

One NO and one NC on the station part – the two contacts are separate, so the NC can feed a safety relay while the NO drives a lamp or a PLC input.

IP69K sealing – a wash down machine sprays the panel at pressure and temperature, and the seal keeps water out of the contact block.

300,000 mechanical operations – the life figure is quoted on the metal part, which is what a machine that is stopped every cycle is checked against.

Three stage enabling – the middle position enables motion, and both release and a full press disable it, which is the behaviour a teach pendant needs.

Applications

These devices are bought by the machine and the way an operator reaches it, and three cases cover most of the requests.

Machine doors and access panels – a 22 mm device in the door frame puts the stop where the operator already reaches, and the twist release means the door can be opened again without a tool.

Machines without an enclosure – a station with a yellow lid carries the device and its cable entry in one part, which is what a conveyor or a stand alone machine uses.

Teach pendants and setup mode – a three stage enabling switch lets an operator jog the machine with the guard open, and the third stage stops the motion if the hand grips in a shock reaction.

The stop circuit and the board that reads it are quoted together, so the SUPERB PCBA and the SUPERB PCB are checked on the same terminal list and the second channel is not left unconnected.

Sourcing and Cross-Reference

Match the contact arrangement to the safety circuit, not to the old device. A single NC part replaces a single NC part, and a two contact part is only useful if the panel has two channels wired for it. Fitting a 1 NO plus 1 NC device where only one NC was used leaves the second contact unconnected and the safety category unchanged.

Check the DC rating before switching a coil. The AC-15 figure of 3 A at 240 V AC is the one on the label, while the same contact is rated 0.27 A at 250 V DC, and a 24 V DC brake or a contactor coil can exceed that. Where the load is DC and inductive, an interposing relay is the cheaper answer than a larger device.

Devices and stations are stock items in the common formats, and the enabling switches follow a cable length. Where a format is short, see lead time and availability, and cross reference when a device on the drawing has been discontinued.

The SUPERB Assembly team keeps the NC pair on its own terminals and labels the NO as signalling only, because a shared terminal is where a two channel circuit quietly becomes one channel.

Q: Can you supply the stop device, the station and the enabling switch for one machine, with the contact arrangement matched to the safety relay?

A: Yes. Send the safety relay, the number of channels and the sealing the machine needs, and the SUPERB Tech team returns the device, the station and the enabling switch that fit.

Why Machine Builders Buy Stop Devices From SUPERB

  1. Contact arrangement on the row: 1 NC and 1 NO plus 1 NC are separated, so the device is bought for the circuit rather than for the picture.
  2. Positive opening stated: the mechanical action is written with the part, which is what a safety assessment asks for.
  3. AC and DC ratings together: the AC-15 and DC-13 figures sit side by side, so a DC coil load is not hidden behind an AC rating.
  4. Sealing and temperature: IP69K and the operating range are listed, which decides whether the device survives a wash down line.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Industrial Pushbuttons and Selector Switches for Panel Fronts, Safety Relay Modules for Guard Monitoring, Door Interlock Switches for Safety Circuits, Mechanical Limit Switches for Position Sensing, Signal Towers and Stack Lights for Machine Status.