A single phase motor needs a capacitor to make a second phase, and the run and start jobs are two different parts. CBB60 run capacitors cover 1 to 60 uF at 250, 370, 440 and 450 VAC in a self healing film can. CD60 start capacitors cover the short time duty range up to 280 uF at 250 VAC in an aluminium can. Can diameter and height are given for each value, because the space on the motor bracket decides the order.
quote now

Product Specifications

Product Overview

A single phase induction motor has no starting torque of its own. A capacitor connected in series with a second winding shifts the current in that winding in time, and the two windings together produce a rotating field that the rotor can follow. The same capacitor, left in circuit while the motor runs, also improves the power factor and the efficiency of the motor.

That is the difference between the two families. A run capacitor stays connected for the life of the motor, so it is a film capacitor with a low dissipation factor and a long life, and it is rated for continuous duty at 450 VAC on a 230 V single phase supply. A start capacitor is connected for a second or two at each start and is an aluminium electrolytic part with a much higher capacitance in the same can, which is what gives the high starting torque. Leaving a start capacitor in circuit destroys it.

Selection comes down to three numbers: the capacitance in microfarad, the AC voltage, and the can size. The capacitance is set by the motor and is written on the old part, and a substitute more than about ten percent away changes the winding current and the temperature rise. The voltage has to be at least the supply, and 450 VAC is the normal rating on a 230 V supply because the capacitor sees the peak of the supply plus the back EMF of the winding.

Key Specifications

ParameterValueNote
Reference standardGB/T 3667.1, IEC 60252-1AC motor capacitors
Run capacitor range1 to 60 uFCBB60 self healing film
Run capacitor voltage250, 370, 440 and 450 VAC450 VAC on a 230 V single phase supply
Start capacitor rangeup to 280 uF in this listCD60 aluminium electrolytic, short time duty
Start capacitor voltage250 VAC110 to 330 VAC exists in the family
Capacitance toleranceplus or minus 5, 10 or 15 percentstate the tolerance with the order
Climatic category40/70/21 and 40/85/21upper temperature decides the life
Class of operationclass B, 10000 hclass C, 3000 h, on the smaller can
Dissipation factor20 x 10 to the minus 4 at 100 Hzfilm run capacitor
Test voltage, terminal to terminal2 times rated voltage for 2 sroutine test
Test voltage, terminal to case2 times rated plus 1000 V AC, or 2000 V AC60 s, routine test
Insulation resistance3000 s or more at 100 Hzfilm run capacitor
Terminalsscrew or pin on the run can, 0.250 in quick connect on the start candual quick connect on the start part
Operating temperature-40 C to +70 C on the run part, -25 C to +65 C on the start partcheck the motor bracket temperature

Included Models and Order Codes

The run capacitor is ordered by capacitance, voltage and can size, and the can grows with the capacitance at a given voltage. The start capacitor is ordered by the capacitance window, because the electrolytic part is sold in a band rather than at a single value, and the band is what the motor sees at the terminals.

Part number or valueTypeCapacitanceVoltageCan sizeNote
CBB60 4 uFrun4 uF450 VAC28.5 x 55 mmsmall fan and pump motors
CBB60 6 uFrun6 uF450 VAC34 x 62 mmcirculation pumps
CBB60 10 uFrun10 uF450 VAC34 x 62 mmcommon value on a 0.55 kW motor
CBB60 15 uFrun15 uF450 VAC37 x 73 mmworkshop machines and compressors
CBB60 20 uFrun20 uF450 VAC40 x 72 mm1.1 kW single phase motor
CBB60 25 uFrun25 uF450 VAC42 x 80 mmlarger compressor and pump
CBB60 30 uFrun30 uF450 VAC42 x 90 mm2.2 kW single phase motor
CBB60 35 uFrun35 uF450 VAC45 x 90 mmcheck the bracket clearance
CBB60 50 uFrun50 uF450 VAC50 x 100 mmlarge single phase compressor
CD60 88 to 106 uFstart88 to 106 uF250 VAC46 x 86 mmstart winding of a small compressor
CD60 145 to 174 uFstart145 to 174 uF250 VAC46 x 111 mmpump and workshop motor
CD60 189 to 227 uFstart189 to 227 uF250 VAC46 x 111 mmcompressor with a high breakaway torque
CD60B-2EJ233280start233 to 280 uF250 VAC65 x 111 mmdual 0.250 in quick connect terminals

Run and Start: The Two Jobs in One Motor

Many single phase motors carry both parts, and mixing them up is the most common failure on this family. The table below is the difference that decides which one goes back on the bracket.

ItemRun capacitorStart capacitor
Dutycontinuousone to three seconds per start
Dielectricmetallised polypropylene filmaluminium electrolytic
Typical capacitance2 to 60 uF70 to 400 uF
Effect on the motorpower factor and running efficiencystarting torque
Failure if left in circuitnone, it is meant to staythe can vents within minutes
Failure signcapacitance falls, motor runs hot and slow to startbulged top, open circuit, no start torque
Replacement rulesame capacitance, voltage at or above the old partsame capacitance band and the same duty

Key Features

Self healing film on the run part – a breakdown in the film clears itself and the capacitor keeps working, which is why the run part survives years of continuous service.

Class B, 10000 hour life – the duty class is stated per can, which sets the expected life at the rated temperature and voltage.

Can size on every value – diameter and height are listed with the capacitance, so a 30 uF part is not ordered for a bracket that takes a 25 uF can.

450 VAC on the run range – the rating covers the peak of a 230 V supply plus the winding back EMF, which is what the part actually sees.

Dual quick connect on the start can – two 0.250 in terminals per connection, so a spade connector can be doubled without an adapter.

Start values given as a band – an electrolytic start part is sold as a capacitance window, and the band is written the way the motor sees it.

Applications

These parts are bought by the motor and the machine it drives, and three cases cover most of the requests.

Pumps and pressure sets – a single phase pump motor runs for hours, so the run capacitor is the part that matters, and a capacitance that has fallen by a fifth shows up as a motor that hums and trips on its thermal protector.

Workshop compressors – a compressor starts against a load and needs the extra torque of a start capacitor, which is switched out by a centrifugal switch once the motor is up to speed.

Fans and circulation blowers – small fan motors use a 4 to 10 uF run capacitor, and the can size is often the limit because the bracket sits inside an air duct.

The motor and its control board are quoted together, so the SUPERB PCBA and the SUPERB PCB are checked on one bill and the capacitor value is taken from the motor rather than from a generic table.

Sourcing and Cross-Reference

Replace by capacitance and voltage, not by size. A 25 uF 450 VAC part and a 30 uF 450 VAC part can share a can diameter, and fitting the wrong one changes the winding current by about twenty percent, which is enough to raise the winding temperature and shorten the motor life.

Check the duty before the value. A start capacitor that is fitted where a run capacitor belongs vents within minutes, and the motor is then blamed for a failure that was a wrong part. On a motor with two cans, the smaller can with the continuous rating is the run part, and the larger electrolytic can is the start part switched by the centrifugal switch.

Motor capacitors are a stock item in most sizes and a production item at the ends of the range. Where a value is short, see lead time and availability, and shortage recovery when a service visit is waiting on one can.

The SUPERB Assembly team marks the run and the start can differently on a harness, because the two are the same shape on some motors and only the label prevents a wrong fit.

Q: Can you supply the run and the start capacitor for one motor as a pair, with the capacitance and the can size confirmed against the old parts?

A: Yes. Send the capacitance and voltage from the old part, the motor rating and a photo of the bracket, and the SUPERB Tech team returns the run part, the start part and the can size that fit.

Why Service Teams Buy Motor Capacitors From SUPERB

  1. Can size beside the value: the physical size is part of the row, so a replacement fits the bracket without a second order.
  2. Duty class stated: class B at 10000 h and class C at 3000 h are separated, which is what sets the life of a run part.
  3. Run and start separated: the two families are not mixed into one table, which removes the failure that comes from fitting a start part in a run position.
  4. Test voltages given: 2 times rated for 2 s and 2000 V AC to case are written out, which is what a service team is asked for on a warranty claim.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Power Factor Correction Capacitors for Panel Compensation, Film Capacitors for Snubber and AC Filter Applications, Contactors and Reversing Contactors for Motor Loads, Thermal Overload Relays for Motor Protection, Soft Starters for Motor Starting.