Contact Us

Brake Rectifiers and Motor Brake Modules

Rectifier modules that feed a DC spring applied brake from the AC supply in the motor terminal box. Half wave types give 0.45 times the input voltage, bridge types 0.9 times, and bridge half wave types switch between the two. Bridge half wave versions overexcite the coil to release the brake fast, then hold it at the lower voltage. Input ranges cover 230 V, 400 V and 555 V mains, with output currents from 0.75 A to 3 A.
quote now

Product Specifications

Product Overview

A spring applied brake holds when no current flows. To release it, the coil needs DC, and on a motor fed from an AC supply that DC comes from a rectifier mounted in the terminal box or in the cabinet. The rectifier is therefore part of the brake release time, not an accessory: the coil inductance and the rectifier output set how fast the brake lets go.

The three circuit shapes behave differently. A half wave rectifier gives 0.45 times the AC input, which suits a brake coil wound for that lower voltage. A bridge rectifier gives 0.9 times the input. A bridge half wave rectifier starts on the bridge voltage, so the coil pulls in with a strong pulse, and then drops to the half wave voltage to hold, which cuts the coil power while the brake is released.

Voltage matching is where most of the errors come from. The coil is marked with its rated DC voltage, and the rectifier is chosen so the output matches at the actual mains voltage. A 205 V coil on a 230 V mains is a bridge type, the same coil on a 400 V mains is not, because 0.9 times 400 V is 360 V and the coil would overheat. The tables below carry the coil voltage next to the rectifier type for that reason.

Key Specifications

Type familyCircuitInput rangeOutput voltageMax output currentAmbient
BEG-261 and BEG-2626-pole half waveup to 460 V or up to 555 V0.45 x input0.75 A at 60 C-20 to +80 C
BEG-5616-pole bridge half wave160 to 440 V0.9 x input, then 0.45 x input1.5 A bridge, 0.75 A half wave-25 to +70 C
BEG-142 and BEG-1434-pole bridgeup to 270 V0.9 x input, nominal 1.11 x for a 205 V coil1.0 A at 60 Cup to +80 C
BEG-242 and BEG-2434-pole half waveup to 555 V0.45 x input, 2.22 x reduction for a 180 V coil1.0 A at 60 Cup to +80 C

Included Models and Order Codes

The last digits of an INTORQ code carry the mains voltage and the variant, and the middle letter carries the mounting position, so BEG-261 is horizontal and BEG-262 is vertical, with the same electrical data. On the bridge half wave types the variant number sets the overexcitation time, which is the window during which the coil sees the higher bridge voltage before the rectifier drops to the hold level. A coil that is released too slowly is often a rectifier whose variant number was chosen for a shorter overexcitation than the brake needs.

Part numberCircuitInput voltageOutput voltageOutput currentOverexcitation
BEG-261-460-01half wave, 6-pole, horizontalup to 460 V AC0.45 x U10.75 Anone
BEG-261-555-01half wave, 6-pole, horizontalup to 555 V AC0.45 x U10.75 Anone
BEG-262-460-01half wave, 6-pole, verticalup to 460 V AC0.45 x U10.75 Anone
BEG-262-555-01half wave, 6-pole, verticalup to 555 V AC0.45 x U10.75 Anone
BEG-561-255-030bridge half wave, 6-pole160 to 255 V AC0.9 then 0.45 x U13.0 A bridge, 1.5 A hold0.30 s at rated input
BEG-561-255-130bridge half wave, 6-pole160 to 255 V AC0.9 then 0.45 x U13.0 A bridge, 1.5 A hold1.30 s at rated input
BEG-561-440-006-1bridge half wave, 6-pole230 to 440 V AC0.9 then 0.45 x U11.5 A bridge, 0.75 A hold0.06 s at rated input
BEG-561-440-030-1bridge half wave, 6-pole230 to 440 V AC0.9 then 0.45 x U11.5 A bridge, 0.75 A hold0.30 s at rated input
BEG-561-440-130bridge half wave, 6-pole230 to 440 V AC0.9 then 0.45 x U13.0 A bridge, 1.5 A hold1.30 s at rated input
BEG-142-270bridge, 4-pole, horizontalup to 270 V AC0.9 x U11.0 Anone
BEG-143-270bridge, 4-pole, verticalup to 270 V AC0.9 x U11.0 Anone
BEG-242-555half wave, 4-pole, horizontalup to 555 V AC0.45 x U11.0 Anone
BEG-243-555half wave, 4-pole, verticalup to 555 V AC0.45 x U11.0 Anone

Coil Voltage Against Mains Voltage

The same brake coil needs a different rectifier on a 230 V mains and on a 400 V mains. The table below is the matching rule we use when a customer sends the brake coil voltage and the supply voltage but no rectifier code, and it is the step that prevents a coil being fed at 360 V from a 400 V line. Where the coil voltage is not marked, the brake maker drawing is the only reliable source.

Coil DC voltage230 V mains400 V mainsWhy
103 Vhalf wave, 0.45 x 230 Vnot applicablehalf wave on 230 V lands close to 103 V
180 Vnot applicablehalf wave, 0.45 x 400 Vthe standard 400 V motor brake coil
205 Vbridge, 0.9 x 230 Vnot applicablebridge on 230 V, the common European brake
360 V and abovenot applicablenot a standard coilcheck the brake drawing before ordering

Key Features

Three circuit shapes in one range – half wave, bridge and bridge half wave, so the rectifier is matched to the coil voltage rather than to what is on the shelf.

Overexcitation variants – the bridge half wave types are ordered with a 0.06 s, 0.30 s or 1.30 s pulse window, which sets how fast the brake lets go.

Horizontal and vertical mounting – the 261 and 262 codes share electrical data and differ only in mounting, which matters inside a motor terminal box.

Varistor protection on input and output – the rectifier clamps the inductive spike from the coil, so the contact that switches it sees a defined voltage.

Up to 555 V input – 400 V and 500 V supplies are covered without a transformer, and the same body is used across the range.

1.0 A and 0.75 A families kept apart – the 4-pole and 6-pole types have different current limits, and mixing them is how a small brake coil ends up on a rectifier that cannot hold it.

Applications

Brake rectifiers are chosen from the brake, not from the motor. Three cases cover most of the work.

Conveyor motor with a spring applied brake – a 205 V coil on a 230 V supply with a bridge rectifier, released when the contactor closes and held while the belt runs.

Hoist on a 400 V supply – an 180 V coil with a half wave rectifier, where the release time is set by the brake spring rather than by the rectifier.

Machine tool axis that must stop fast – a bridge half wave rectifier with a short overexcitation window, so the coil pulls in hard and then holds at the lower voltage.

The brake circuit is quoted with the drive board that switches it, so the SUPERB PCBA and the SUPERB PCB are checked for the freewheel path that protects the rectifier when the contact opens.

Sourcing and Cross-Reference

Read the coil voltage off the brake, not off the motor. The brake coil is a separate circuit and its marking is the only figure that decides the rectifier. A motor nameplate gives the mains voltage, and a rectifier chosen from that alone will either underdrive the coil, so the brake drags, or overdrive it, so the coil cooks.

Match the output current to the coil resistance at the hold voltage. The 6-pole half wave types are limited to 0.75 A at 60 C, and the 4-pole bridge types to 1.0 A. A coil that needs 1.2 A at the hold level is outside both, and the answer is a larger rectifier rather than a higher ambient rating.

Choose the overexcitation window from the brake release time, not from the largest number. A long window releases a heavy armature faster and heats the coil more, and on a brake that is switched every few seconds the long window is what shortens coil life. The 0.06 s variant exists for exactly that duty.

A rectifier is a small part with a long lead time when the variant is unusual, so the code is confirmed before the panel is scheduled. See lead time and availability for the position today, and the cross reference hub when the brake maker has changed the recommended module.

The SUPERB Assembly team mounts the rectifier on the brake side of the terminal box, because a module bolted to the frame beside the cable gland picks up the vibration that loosens the spade terminals.

Q: Can you supply the rectifier that matches our brake coil voltage on the mains we have, including the overexcitation variant?

A: Yes. Send the brake coil voltage, the mains voltage at the motor and the release time you need, and the SUPERB Tech team returns the rectifier type, the overexcitation variant and the mounting position.

Why Machine Builders Buy Brake Rectifiers From SUPERB

  1. Coil voltage checked first: the brake marking and the mains voltage are compared before a code is quoted, which is the step that prevents a 360 V feed into a 205 V coil.
  2. Overexcitation window stated: the 0.06 s, 0.30 s and 1.30 s variants are listed separately, because the window sets the release time.
  3. Mounting position in the code: horizontal and vertical bodies are listed as separate parts, which matters in a terminal box with one cable entry.
  4. Small parts held as spares: the rectifier is the part that fails when a brake coil is replaced, so it is quoted with the brake rather than after the failure.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Contactors and Reversing Contactors for Motor Loads, Motor Protection Circuit Breakers for Panel Feeders, Bridge Rectifiers and Schottky Rectifier Diodes, DIN Rail Power Supplies for Control Cabinets, Surge Protective Devices for AC Distribution Boards.