Fiber Collimators and Patch Cords for Photometric Probes
Product Specifications
Product Overview
A photometric probe is only as good as the two ends of its fiber run. On the instrument side a collimating lens sets the beam diameter and the working distance; on the sample side the same lens, reversed, decides how much light comes back. When a channel reads weak, the usual culprits are a mismatched focal length, a fiber core that is larger than the detector window, or a cord that has solarized after years under a deuterium lamp.
The lens tables below are split by throw distance rather than by brand. The f/2 single lenses at 10 mm focal length cover the short probe runs inside an analyser, the achromatic doublet removes the colour focus shift when a white lamp is used across the whole visible band, and the f/4 lens at 100 mm focal length throws a parallel beam across an open bench or a long air path.
Fiber core and numerical aperture have to match at both ends. A 600 um core cord on a 200 um collimator wastes light and widens the spot; a 105 um core cord on a large aperture lens under fills it. The step index cords listed here are available in high OH glass for the UV end and low OH glass for the visible to NIR end, and the size suffix on the maker number gives the length in metres.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Lens type | f/2 single lens, f/2 doublet, f/4 single lens | Selected by throw distance |
| Lens diameter | 5 mm to 30 mm | 5 mm on the 74 series, 30 mm on COL-UV-30 |
| Focal length | 10 mm to 100 mm | 10 mm standard, 100 mm for long throw |
| Fiber core | 25 um to 600 um | Step index multimode |
| Numerical aperture | 0.10 to 0.51 | Collimator and cord must agree |
| Fiber connector | SMA 905 or FC/APC | 3/8-24 external thread on SMA bodies |
| Collimator body | 12 mm outer diameter | F240APC series, M12 x 0.5 thread |
| Wavelength range | 190 nm to 2200 nm | High OH for UV, low OH for NIR |
| Cord jacket | Silicone coated steel monocoil | QP series, protects against crushing |
| Operating temperature | 70 C to 250 C | Depends on the lens body |
Included Models and Order Codes
Lenses are listed first, then cords. On the 74 series the number after the dash is the wavelength version, and the HT-VAC part is the high temperature version used inside heated sample compartments. On the patch cords the letter prefix gives the core size, the suffix 01 means one metre, and the two digit number before SR or L is the core in hundreds of micrometres.
| Part Number | Type | Wavelength Range | Lens or Core | Connector | Note |
|---|---|---|---|---|---|
| 74-UV | Collimating lens | 200 to 2000 nm | f/2, f = 10 mm, 5 mm dia | SMA 905 | 150 C body |
| 74-VIS | Collimating lens | 350 to 2000 nm | f/2 BK-7, f = 10 mm | SMA 905 | Visible version |
| 74-ACR | Achromatic doublet | 350 to 2000 nm | f/2, f = 10 mm | SMA 905 | No colour focus shift |
| 74-90-UV | Right angle collimator | 200 to 2000 nm | f/2, f = 10 mm | SMA 905 | Mirror turns the beam 90 degrees |
| 74-UV-HT-VAC | High temperature lens | 190 to 2000 nm | f/2, f = 10 mm | SMA 905 | 250 C rated |
| COL-UV-30 | Large aperture lens | 200 to 2000 nm | f/2, f = 30 mm, 30 mm dia | SMA 905 | Collects more light |
| 84-UV-25 | Long throw collimator | 200 to 2000 nm | f/4, f = 100 mm, 25.4 mm dia | SMA 905 | Open air paths |
| F240APC-A | Fixed focus collimator | 350 to 700 nm | f = 7.86 mm, NA 0.51 | FC/APC | Aligned at 543 nm |
| F240APC-1550 | Fixed focus collimator | 1550 nm | f = 8.18 mm, NA 0.49 | FC/APC | NIR version |
| QP600-2-SR | Patch cord | 200 to 1100 nm | 600 um core, 2 m | SMA 905 | Solarization resistant |
| M15L01 | Patch cord | 400 to 2400 nm | 105 um core, 0.22 NA, 1 m | SMA | Low OH |
| M92L01 | Patch cord | 250 to 1200 nm | 200 um core, 0.22 NA, 1 m | SMA | High OH |
| M28L01 | Patch cord | 400 to 2200 nm | 400 um core, 0.39 NA, 1 m | SMA | Low OH |
| M29L01 | Patch cord | 400 to 2200 nm | 600 um core, 0.39 NA, 1 m | SMA | Low OH |
| M37L01 | Patch cord | 400 to 2200 nm | 550 um core, 0.22 NA, 1 m | SMA | Low OH |
| M44L01 | Patch cord | 400 to 2200 nm | 200 um core, 0.50 NA, 1 m | SMA | Low OH |
Key Features
Focus set by sliding barrel – the inner barrel moves against a setscrew, so the focus can be reset on the bench without a fixture
Doublet option – the achromatic version holds focus across the visible band, which matters when the source is a tungsten halogen lamp
100 mm throw available – the f/4 lens at 100 mm focal length keeps a parallel beam over a long air path
High temperature bodies – the HT-VAC lens is rated to 250 C for use inside a heated compartment
UV to NIR cords – high OH glass covers 250 to 1200 nm and low OH glass covers 400 to 2400 nm
Solarization resistant cord – the SR cord keeps transmission in the deep UV where a standard cord darkens with lamp hours
Matched core and NA – cords are listed with core and numerical aperture so the pair can be checked against the collimator
Small 12 mm body – the FC/APC fixed focus collimator fits a 12 mm bore with an M12 x 0.5 thread
Applications
Fiber links appear wherever the light has to leave the measuring head, from a cuvette in a heated block to a probe in a fermenter.
Dip probes and immersion assemblies – a collimator pair sets the path length across the probe gap and returns light to the spectrometer
Flow cells and cuvette holders – short f/2 lenses couple a flow cell to the instrument with minimal stray light
Process and online analysers – patch cords carry the signal from a field enclosure to the analyser without an electrical path
Fiber assemblies on this page are supplied by the same SUPERB PCB and SUPERB PCBA teams that build the spectrometer boards they connect to.
Sourcing and Cross-Reference
The first question for any replacement is the focal length, not the brand. A 10 mm f/2 lens and a 7.86 mm asphere look alike on a bench but produce different beam diameters at the same working distance, and that changes the reading on a narrow flow cell. We confirm the focal length, the lens diameter and the connector before quoting.
Cords are matched on three numbers: core diameter, numerical aperture and wavelength range. A cord with the right core but the wrong OH content will lose the UV end after a few hundred lamp hours, which is the failure mode most often reported as a weak lamp. For UV work the solarization resistant cord is the correct choice even though it costs more.
Fiber assemblies are consumables on most analysers, so a planned replacement beats a failed run. We quote the lens, the cord and the mating sleeve together, and hold to the original connector and thread so the field engineer does not have to modify the head.
Where a probe head carries its own preamp, the board is built through SUPERB Assembly and shipped with the optical parts.
Q: Can you match a collimator and patch cord to a probe we already have in the field?
A: Yes. SUPERB Tech matches the collimator and the cord to the probe you already have, and confirms the thread and connector before quoting.
Why Choose SUPERB for Fiber Optic Assemblies
- Focal length first: the replacement is matched on focal length and beam diameter, so the reading on a narrow cell does not change
- Core and NA checked: cord and collimator are confirmed as a pair rather than as two separate parts
- UV cords held: solarization resistant cord is quoted for lamp based systems instead of standard visible cord
- Connector kept original: SMA 905 and FC/APC bodies are supplied with the original thread so no adapter is needed
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Flow Cell Holders and Cuvette Changers, Quartz Flow Cells and Cuvettes, Immersion Assemblies and Sample Probes, Photodiode Arrays and Detector Modules, Xenon and Deuterium Lamps, Dichroic Filters and Beam Splitters.