Fiber Collimators and Patch Cords for Photometric Probes

Collimating lenses and patch cords for photometric probes and dip cells. Lens options from f/2 at 10 mm focal length up to f/4 at 100 mm for long throw. Fixed focus FC/APC collimators at 543 nm and 1550 nm in a 12 mm body. Step index cords from 105 um to 600 um core in high OH and low OH glass.
quote now

Product Specifications

Product Overview

A photometric probe is only as good as the two ends of its fiber run. On the instrument side a collimating lens sets the beam diameter and the working distance; on the sample side the same lens, reversed, decides how much light comes back. When a channel reads weak, the usual culprits are a mismatched focal length, a fiber core that is larger than the detector window, or a cord that has solarized after years under a deuterium lamp.

The lens tables below are split by throw distance rather than by brand. The f/2 single lenses at 10 mm focal length cover the short probe runs inside an analyser, the achromatic doublet removes the colour focus shift when a white lamp is used across the whole visible band, and the f/4 lens at 100 mm focal length throws a parallel beam across an open bench or a long air path.

Fiber core and numerical aperture have to match at both ends. A 600 um core cord on a 200 um collimator wastes light and widens the spot; a 105 um core cord on a large aperture lens under fills it. The step index cords listed here are available in high OH glass for the UV end and low OH glass for the visible to NIR end, and the size suffix on the maker number gives the length in metres.

Key Specifications

ParameterValueNotes
Lens typef/2 single lens, f/2 doublet, f/4 single lensSelected by throw distance
Lens diameter5 mm to 30 mm5 mm on the 74 series, 30 mm on COL-UV-30
Focal length10 mm to 100 mm10 mm standard, 100 mm for long throw
Fiber core25 um to 600 umStep index multimode
Numerical aperture0.10 to 0.51Collimator and cord must agree
Fiber connectorSMA 905 or FC/APC3/8-24 external thread on SMA bodies
Collimator body12 mm outer diameterF240APC series, M12 x 0.5 thread
Wavelength range190 nm to 2200 nmHigh OH for UV, low OH for NIR
Cord jacketSilicone coated steel monocoilQP series, protects against crushing
Operating temperature70 C to 250 CDepends on the lens body

Included Models and Order Codes

Lenses are listed first, then cords. On the 74 series the number after the dash is the wavelength version, and the HT-VAC part is the high temperature version used inside heated sample compartments. On the patch cords the letter prefix gives the core size, the suffix 01 means one metre, and the two digit number before SR or L is the core in hundreds of micrometres.

Part NumberTypeWavelength RangeLens or CoreConnectorNote
74-UVCollimating lens200 to 2000 nmf/2, f = 10 mm, 5 mm diaSMA 905150 C body
74-VISCollimating lens350 to 2000 nmf/2 BK-7, f = 10 mmSMA 905Visible version
74-ACRAchromatic doublet350 to 2000 nmf/2, f = 10 mmSMA 905No colour focus shift
74-90-UVRight angle collimator200 to 2000 nmf/2, f = 10 mmSMA 905Mirror turns the beam 90 degrees
74-UV-HT-VACHigh temperature lens190 to 2000 nmf/2, f = 10 mmSMA 905250 C rated
COL-UV-30Large aperture lens200 to 2000 nmf/2, f = 30 mm, 30 mm diaSMA 905Collects more light
84-UV-25Long throw collimator200 to 2000 nmf/4, f = 100 mm, 25.4 mm diaSMA 905Open air paths
F240APC-AFixed focus collimator350 to 700 nmf = 7.86 mm, NA 0.51FC/APCAligned at 543 nm
F240APC-1550Fixed focus collimator1550 nmf = 8.18 mm, NA 0.49FC/APCNIR version
QP600-2-SRPatch cord200 to 1100 nm600 um core, 2 mSMA 905Solarization resistant
M15L01Patch cord400 to 2400 nm105 um core, 0.22 NA, 1 mSMALow OH
M92L01Patch cord250 to 1200 nm200 um core, 0.22 NA, 1 mSMAHigh OH
M28L01Patch cord400 to 2200 nm400 um core, 0.39 NA, 1 mSMALow OH
M29L01Patch cord400 to 2200 nm600 um core, 0.39 NA, 1 mSMALow OH
M37L01Patch cord400 to 2200 nm550 um core, 0.22 NA, 1 mSMALow OH
M44L01Patch cord400 to 2200 nm200 um core, 0.50 NA, 1 mSMALow OH

Key Features

Focus set by sliding barrel – the inner barrel moves against a setscrew, so the focus can be reset on the bench without a fixture

Doublet option – the achromatic version holds focus across the visible band, which matters when the source is a tungsten halogen lamp

100 mm throw available – the f/4 lens at 100 mm focal length keeps a parallel beam over a long air path

High temperature bodies – the HT-VAC lens is rated to 250 C for use inside a heated compartment

UV to NIR cords – high OH glass covers 250 to 1200 nm and low OH glass covers 400 to 2400 nm

Solarization resistant cord – the SR cord keeps transmission in the deep UV where a standard cord darkens with lamp hours

Matched core and NA – cords are listed with core and numerical aperture so the pair can be checked against the collimator

Small 12 mm body – the FC/APC fixed focus collimator fits a 12 mm bore with an M12 x 0.5 thread

Applications

Fiber links appear wherever the light has to leave the measuring head, from a cuvette in a heated block to a probe in a fermenter.

Dip probes and immersion assemblies – a collimator pair sets the path length across the probe gap and returns light to the spectrometer

Flow cells and cuvette holders – short f/2 lenses couple a flow cell to the instrument with minimal stray light

Process and online analysers – patch cords carry the signal from a field enclosure to the analyser without an electrical path

Fiber assemblies on this page are supplied by the same SUPERB PCB and SUPERB PCBA teams that build the spectrometer boards they connect to.

Sourcing and Cross-Reference

The first question for any replacement is the focal length, not the brand. A 10 mm f/2 lens and a 7.86 mm asphere look alike on a bench but produce different beam diameters at the same working distance, and that changes the reading on a narrow flow cell. We confirm the focal length, the lens diameter and the connector before quoting.

Cords are matched on three numbers: core diameter, numerical aperture and wavelength range. A cord with the right core but the wrong OH content will lose the UV end after a few hundred lamp hours, which is the failure mode most often reported as a weak lamp. For UV work the solarization resistant cord is the correct choice even though it costs more.

Fiber assemblies are consumables on most analysers, so a planned replacement beats a failed run. We quote the lens, the cord and the mating sleeve together, and hold to the original connector and thread so the field engineer does not have to modify the head.

Where a probe head carries its own preamp, the board is built through SUPERB Assembly and shipped with the optical parts.

Q: Can you match a collimator and patch cord to a probe we already have in the field?

A: Yes. SUPERB Tech matches the collimator and the cord to the probe you already have, and confirms the thread and connector before quoting.

Why Choose SUPERB for Fiber Optic Assemblies

  1. Focal length first: the replacement is matched on focal length and beam diameter, so the reading on a narrow cell does not change
  2. Core and NA checked: cord and collimator are confirmed as a pair rather than as two separate parts
  3. UV cords held: solarization resistant cord is quoted for lamp based systems instead of standard visible cord
  4. Connector kept original: SMA 905 and FC/APC bodies are supplied with the original thread so no adapter is needed

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Flow Cell Holders and Cuvette Changers, Quartz Flow Cells and Cuvettes, Immersion Assemblies and Sample Probes, Photodiode Arrays and Detector Modules, Xenon and Deuterium Lamps, Dichroic Filters and Beam Splitters.