Dichroic Filters and Beam Splitters for Photometric Channels
Product Specifications
Product Overview
A photometric channel separates two things at one surface: excitation from emission in a fluorescence reader, or sample from reference in an absorbance photometer. That surface sits at 45 degrees, and when it drifts the whole calibration curve moves with it. Most service teams replace the optic rather than touch the detector gain, which is why the cut on wavelength and the split ratio have to be read off the part number before anything is ordered.
Every optic on this page is coated for 45 degree incidence, because that is how it sits in the filter block. A dichroic quoted at normal incidence shifts its edge by tens of nanometres once it is tilted into a channel, and that shift is the usual reason a replacement filter reads low on the emission side. Surface quality is 40-20 scratch dig and transmitted wavefront is held below lambda/4 at 633 nm, so inserting the optic does not defocus the sample image.
The bench around the splitter matters as much as the splitter. These parts are specified to work with our bandpass and interference filters and the entrance slits ahead of them, and the same optical train continues through monochromator gratings and photodiode arrays.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Angle of incidence | 45 degrees | Coatings are specified at this angle only |
| Cut on wavelength | 505 nm to 900 nm | Longpass dichroics listed here |
| Transmission, DMLP550 | 90% or more, average, 565 to 800 nm | 85% absolute in the same band |
| Reflection, DMLP550 | 95% or more, average, 380 to 533 nm | 90% absolute in the same band |
| Dichroic substrate | UV fused silica | Hard oxide coating, cleanable |
| Cube substrate | N-BK7 | 400 to 700 nm and 700 to 1100 nm cubes |
| Surface quality | 40-20 scratch dig | Dichroics and plate splitters |
| Transmitted wavefront | Under lambda/4 at 633 nm | Dichroics and cubes |
| Clear aperture | 22.86 mm on 1 inch round | More than 20.3 x 20.3 mm inside 1 inch cubes |
| Split ratio tolerance | +/- 8% | 25 x 36 mm plate splitters |
| Plate thickness | 1.0 mm | 25 x 36 mm plate splitters |
Included Models and Order Codes
Two families are listed below. On a longpass dichroic the number is the cut on wavelength; on a plate splitter the number is the split ratio. Size follows the suffix used by the maker: no suffix is 1 inch round, R is 25 x 36 mm, and L is 2 inch round. The two Semrock edges are shown because they are the parts most often asked for by number, and both are now shown as obsolete by the maker, so they are handled as a last time buy.
| Part Number | Type | Edge or Split | Transmission | Reflection | Size |
|---|---|---|---|---|---|
| DMLP505 | Longpass dichroic | 505 nm cut on | Above 505 nm | Below 505 nm | 25.4 mm round |
| DMLP550 | Longpass dichroic | 550 nm cut on | 565 to 800 nm | 380 to 533 nm | 25.4 mm round |
| DMLP650 | Longpass dichroic | 650 nm cut on | Above 650 nm | Below 650 nm | 25.4 mm round |
| DMLP805 | Longpass dichroic | 805 nm cut on | Above 805 nm | Below 805 nm | 25.4 mm round |
| DMLP900 | Longpass dichroic | 900 nm cut on | Above 900 nm | Below 900 nm | 25.4 mm round |
| DMLP550R | Longpass dichroic | 550 nm cut on | 565 to 800 nm | 380 to 533 nm | 25 x 36 mm |
| DMLP650R | Longpass dichroic | 650 nm cut on | Above 650 nm | Below 650 nm | 25 x 36 mm |
| FF562-Di03-25x36 | Single edge dichroic | 562 nm edge | Long side of 562 nm | Short side of 562 nm | 25.2 x 35.6 x 1.05 mm |
| FF495-Di03-25x36 | Single edge dichroic | 495 nm edge | Long side of 495 nm | Short side of 495 nm | 25.2 x 35.6 x 1.05 mm |
| BS010 | Non polarizing cube | 50:50 | 50% | 50% | 10 mm cube |
| BS016 | Non polarizing cube | 50:50 | 50% | 50% | 20 mm cube |
| BS013 | Non polarizing cube | 50:50 | 50% | 50% | 25.4 mm cube |
| BS014 | Non polarizing cube | 50:50 | 50% | 50% | 25.4 mm cube, 700 to 1100 nm |
| BSN10R | Plate splitter | 10:90 | 90% | 10% | 25 x 36 x 1 mm |
| BSS10R | Plate splitter | 30:70 | 70% | 30% | 25 x 36 x 1 mm |
| BSW10R | Plate splitter | 50:50 | 50% | 50% | 25 x 36 x 1 mm |
| BST10R | Plate splitter | 70:30 | 30% | 70% | 25 x 36 x 1 mm |
| BSX10R | Plate splitter | 90:10 | 10% | 90% | 25 x 36 x 1 mm |
| BSW26R | Plate splitter | 50:50 | 50 +/- 12%, 350 to 1100 nm | 50 +/- 12% | 25 x 36 x 1 mm |
Key Features
Edge held at 45 degrees – the coating is specified for the incidence used in a filter block, so the edge lands where the maker plots it once the optic is seated
Hard oxide coating – the dichroic stack can be cleaned with solvent and lens tissue, unlike a soft coated first surface mirror
Wavefront kept flat – transmitted wavefront below lambda/4 at 633 nm keeps the sample image in focus after the optic is swapped
Cube for compact benches – 10 mm and 20 mm cubes fold the path inside a solid block, which holds alignment in handheld and field instruments
Five plate ratios – 25 x 36 mm plates come in 10:90, 30:70, 50:50, 70:30 and 90:10 so a reference channel can be tapped without a second lamp
Splitter to 1100 nm – BSW26R holds 50:50 from 350 to 1100 nm with transmission plus reflection above 99%, which suits tungsten halogen sources
NIR edges available – cut on wavelengths to 900 nm cover moisture and protein channels in NIR analysers
Obsolete edges supported – FF562-Di03 and FF495-Di03 are listed as obsolete by the maker and are sourced against the original number
Applications
These optics sit in the wavelength separating position of a photometric instrument, so the application decides which edge and which ratio is correct.
Clinical chemistry and immunoassay analysers – a longpass dichroic splits excitation from emission so the detector only sees the fluorophore band
Water, beverage and process photometers – a plate splitter taps a reference path from a single lamp so lamp ageing cancels out
Handheld and field instruments – a 10 mm cube holds a folded path stable when the unit is carried and bumped
Photometric optics for these builds are supplied by SUPERB PCB and SUPERB PCBA teams that already handle the driver and signal boards behind the channel.
Sourcing and Cross-Reference
Filters are ordered by cut on wavelength and by size suffix, not by the instrument model. When only the instrument and the slot are known, the edge can be recovered from the assay wavelength pair: the reflection band has to cover the excitation line and the transmission band has to cover the emission line, with a gap of at least 20 nm around the edge to allow for tilt.
Second sourcing is straightforward for plate splitters, where a 50:50 in 25 x 36 x 1 mm can be compared on coating range, split tolerance and surface quality. It is not straightforward for a dichroic edge, because two makers place the edge differently at the same nominal wavelength. For those we compare the plotted bands, not the headline number.
Both Semrock edges listed above are shown as obsolete by the maker. That is not a reason to change the instrument: the replacement is confirmed against the original part number, the transmission curve is checked on both sides of the edge, and a last time buy is placed while stock is still reachable.
When the instrument also needs a new control board, assemblies run through SUPERB Assembly so the optical and electrical sides ship on one schedule.
Q: Can you supply a replacement dichroic when the original part number is discontinued?
A: Yes. SUPERB Tech confirms the discontinued edge against the original number, checks both sides of the band, and quotes a last time buy while stock is reachable.
Why Choose SUPERB for Photometric Optics
- Specified at the angle it is used: an edge quoted at 45 degrees behaves differently from one quoted at normal incidence, and the difference is visible on the calibration curve
- Numbers traced to the maker: cut on wavelength, split ratio, surface quality and wavefront come from the published data, not from a catalogue summary
- Optics and boards on one order: the same account can cover the optical spare and the driver board behind it, which shortens the service loop
- Obsolete parts handled first: discontinued edges are checked before a substitute is proposed, so the instrument keeps its original calibration
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Bandpass and Interference Filters, Optical Slits and Apertures, Monochromator Gratings and Bench Parts, Quartz Flow Cells and Cuvettes, Lamp Housings and Shutters, Photodiode Arrays and Detector Modules.