Lenses and Mirrors for Optical Benches
Product Specifications
Product Overview
Most analyser benches are built from four parts: a source, a wavelength selector, a sample cell and a detector. Lenses and mirrors do the quiet work in between, and when one is replaced with the wrong focal length or the wrong coating the instrument still runs, it just reads low and drifts. This page lists the plano convex lenses and the flat and concave mirrors used in those positions, with coating range and surface quality stated per part.
Two numbers decide whether a lens will do the job. The first is focal length at the sodium d line, which sets the throw and the spot size. The second is the AR coating range, which decides how much light survives each surface: an uncoated N-BK7 surface loses about 4% by reflection, and the coated versions bring that below 0.5% average over the coated band. A lens coated for 400 to 1100 nm used in a 350 nm channel loses more than the datasheet suggests.
Mirrors are simpler to compare. A protected silver coating holds above 97.5% average from 450 nm to 2 um and above 96% from 2 to 20 um, which covers the visible, NIR and most of the mid infrared in one part. Flatness matters when the mirror is in an imaging path: the 1 inch protected silver flats are polished to lambda/10 at 633 nm, so they do not add curvature to a relay.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Lens shape | Plano convex | N-BK7 grade A substrate |
| Focal length range | 15 mm to 1000 mm | Tolerance +/- 1% |
| Lens diameter | 12.7 mm, 25.4 mm, 50.8 mm | Half inch, 1 inch and 2 inch |
| Clear aperture | 90% of diameter | 22.86 mm on a 1 inch lens |
| Surface quality | 40-20 scratch dig | Lens and mirror surfaces |
| Lens flatness | lambda/2 plano side | Irregularity lambda/4 |
| AR coating options | 350-700 nm, 400-1100 nm, 1.65-3.0 um | Average reflectance below 1% at 0 degrees |
| Mirror substrate | UV fused silica | Protected silver coating |
| Mirror reflectance | 97.5% or more, average, 450 nm to 2 um | 96% or more, average, 2 to 20 um |
| Mirror flatness | lambda/10 at 633 nm | 1 inch protected silver flats |
| Concave mirror body | 25.4 mm diameter, 6.0 mm thick | 100.0 mm focal length |
Included Models and Order Codes
Lenses are listed by focal length and coating suffix, mirrors by coating and size. The dash suffix on a Thorlabs lens is the coating band: A is 350 to 700 nm, AB is 400 to 1100 nm, D is 1.65 to 3.0 um. On mirrors, P01 is protected silver and the E02 and E03 suffixes are the dielectric bands for 400 to 750 nm and 750 to 1100 nm.
| Part Number | Type | Focal Length | Diameter | Thickness | Coating |
|---|---|---|---|---|---|
| LA1131-A | Plano convex lens | 49.8 mm | 25.4 mm | 5.3 mm centre | AR 350 to 700 nm |
| LA1131-AB | Plano convex lens | 49.8 mm | 25.4 mm | 5.3 mm centre | AR 400 to 1100 nm |
| LA1131-D | Plano convex lens | 49.8 mm | 25.4 mm | 5.3 mm centre | AR 1.65 to 3.0 um |
| PF05-03-P01 | Flat mirror | Flat | 12.7 mm | 6.0 mm | Protected silver |
| PF10-03-P01 | Flat mirror | Flat | 25.4 mm | 6.0 mm | Protected silver, lambda/10 |
| PF20-03-P01 | Flat mirror | Flat | 50.8 mm | 6.0 mm | Protected silver |
| PF10-03-P01P | Back side polished mirror | Flat | 25.4 mm | 6.0 mm | Protected silver, 450 nm to 20 um |
| PF10-03-E02 | Dielectric flat mirror | Flat | 25.4 mm | 6.0 mm | 400 to 750 nm, 99% or more average |
| PF10-03-E03 | Dielectric flat mirror | Flat | 25.4 mm | 6.0 mm | 750 to 1100 nm, 99% or more average |
| CM254-100-P01 | Concave mirror | 100.0 mm | 25.4 mm | 6.0 mm | Protected silver |
Key Features
Three coating bands – the same 49.8 mm lens is stocked for the visible, for the visible to NIR and for the 1.65 to 3.0 um range, so the channel does not have to be compromised
Focal length held to 1% – the quoted focal length is measured at 587.6 nm, which keeps the throw predictable from part to part
Surface quality 40-20 – a scratch dig specification that will not scatter light into a low level detector
Plano side flat to lambda/2 – the flat face can be used as a reference surface in a folded path
Silver over 450 nm to 20 um – one coating covers visible, NIR and mid infrared, which simplifies spares holding
Flat to lambda/10 – the 1 inch protected silver flat does not add curvature to an imaging relay
Dielectric option above 99% – the E02 and E03 coatings give higher reflectance than silver inside their bands
Concave for relay paths – a 100 mm focal length concave mirror folds and focuses in one surface, which removes a lens from the path
Applications
Lenses and mirrors are chosen by what the light has to do next, so the application decides the focal length and the coating together.
Cuvette and flow cell optics – a plano convex lens images the cell volume onto the entrance slit without overfilling it
Reference and beam folding paths – a protected silver flat folds the beam with more than 97.5% reflectance across the visible and NIR
Detector collection – a concave mirror collects light that would otherwise miss a small active area
Bench optics are supplied alongside SUPERB PCB and SUPERB PCBA work for the same analyser, so the mechanical and electrical sides stay on one order.
Sourcing and Cross-Reference
Focal length and coating band are the two numbers that decide a lens replacement, and neither can be read from the instrument model. We confirm both, plus the diameter and the clear aperture, before quoting, because a 1 inch lens with a 22.86 mm clear aperture will vignette a beam that a 2 inch lens would pass.
For mirrors the choice between silver and dielectric is a question of band and of loss budget. Silver covers 450 nm to 20 um at 97.5% average, which is the right answer for a multi purpose instrument; a dielectric coating reaches above 99% but only inside one band, so it is used where a single source wavelength dominates.
Bench optics are also the parts most often damaged during service, so it is worth holding a spare of the lens and flat used in each channel. We quote in the sizes and coatings listed above and can add a matched spare set to an analyser build order.
Boards that sit behind the bench, such as lamp drivers and preamps, run through SUPERB Assembly.
Q: Can you supply a lens or mirror with the same focal length and coating as the original?
A: Yes. SUPERB Tech confirms focal length and coating band against the original part and quotes a like for like replacement.
Why Choose SUPERB for Bench Optics
- Focal length confirmed first: the replacement is matched on measured focal length, not on the outside diameter of the mount
- Coating band checked: the AR band is compared with the channel wavelength before a part is proposed
- Flatness stated: mirror flatness is quoted so an imaging path is not degraded by a substitute
- Spares quoted with builds: a matched spare lens and flat can be added to an analyser order instead of being sourced after a failure
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Dichroic Filters and Beam Splitters, Monochromator Gratings and Bench Parts, Optical Windows and Sapphire Discs, Optical Slits and Apertures, Lamp Housings and Shutters, Bandpass and Interference Filters.