Autosampler Vials and Septa for HPLC
Product Specifications
Product Overview
A 2 mL vial looks like a commodity until the autosampler starts missing it. Three tolerances decide whether the needle finds the sample: the 12 mm body diameter that locates the vial in the tray, the 32 mm height that sets the needle depth, and the neck finish that holds the cap square. A vial that is half a millimetre out on height sits low, and the needle either bends or draws air rather than liquid.
The closure is half of the part. For LC and LC/MS work the wide opening screw vial with a 9 mm septum under a 12 mm cap is the common choice, because a screw cap can be re tightened and it reseals after several injections. For GC and GC/MS work the 11 mm crimp neck gives a tighter seal on volatile samples, a wider target for the needle, and a closure that cannot work loose in the tray. Both formats are on this page, with the caps and septa that match them.
Septa are ordered separately from caps and vials, and the material sets the temperature ceiling and the bleed level. PTFE faced silicone covers most LC and GC runs up to 200 °C. A PTFE silicone PTFE sandwich is used for trace work where silicone bleed reaches the detector. BTO inlet septa are a different part again: they sit in the injection port of a GC, not on the vial, and run to 400 °C.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Vial format | 12 x 32 mm, 2 mL | Wide opening, 6 mm opening diameter |
| Glass | Clear or amber, 5% borosilicate | Type 1 Class for hydrolytic and acid resistance |
| Screw neck | 9 mm septum, 12 mm cap | LC and LC/MS trays |
| Crimp neck | 11 mm septum and cap | GC and GC/MS, volatile samples |
| Certified status | Certified lots, dimension checked | Needle height and tray fit |
| Septa materials | PTFE/silicone, PTFE/silicone/PTFE, PTFE/red rubber, BTO silicone | Temperature and bleed differ |
| Septa temperature | -40 to 200 °C for PTFE faced, 400 °C for BTO inlet septa | Per material, check before use |
| Reseal after injection | Yes for PTFE/silicone and sandwich | No for PTFE/red rubber |
| Pack sizes | 25, 100, 500 and 1000 per pack | Convenience packs combine vial and cap |
Included Models and Order Codes
The first block is the LC family in screw neck, the second is the GC family in crimp neck, and the third is the septum and cap range that closes both. Part numbers with a write-on spot carry a ceramic patch for sample identity. Convenience packs are single part numbers that arrive with the cap and septum already fitted, which removes one assembly step in the lab.
| Part Number | Format | Glass or Colour | Closure | Pack | Use |
|---|---|---|---|---|---|
| 5182-0714 | 2 mL screw top | Clear, certified | 9 mm screw neck | 100/pk | LC routine |
| 5182-0715 | 2 mL screw top | Clear, write-on spot | 9 mm screw neck | 100/pk | Sample identity |
| 5182-0716 | 2 mL screw top | Amber, write-on spot | 9 mm screw neck | 100/pk | Light sensitive samples |
| 5183-2068 | 2 mL screw top | Clear, write-on spot | 9 mm screw neck | 1000/cs | Bulk LC trays |
| 5182-0717 | Screw cap | Blue polypropylene | PTFE/red silicone septum | 100/pk | Screw vial closure |
| 5185-5820 | Screw cap | Blue polypropylene | PTFE/red silicone septum | 500/pk | Screw vial closure |
| 5190-1599 | Screw cap | Blue polypropylene | PTFE/red silicone septum | 1000/pk | Bulk closure |
| 5182-0868 | Convenience pack | Clear, write-on spot | Blue cap, PTFE/silicone | 500/pk | One part number |
| 5182-0864 | Convenience pack | Clear, write-on spot | Blue cap, PTFE/red rubber | 100/pk | One part number |
| 5181-3375 | 2 mL crimp top | Clear, certified | 11 mm crimp neck | 100/pk | GC routine |
| 5182-0543 | 2 mL crimp top | Clear, write-on spot | 11 mm crimp neck | 100/pk | Sample identity |
| 5181-3376 | 2 mL crimp top | Amber, write-on spot | 11 mm crimp neck | 100/pk | Light sensitive samples |
| 5183-4491 | 2 mL crimp top | Clear | 11 mm crimp neck | 1000/cs | Bulk GC trays |
| 5182-0552 | Crimp cap | Silver aluminium | PTFE/silicone septum | 100/pk | Crimp vial closure |
| 5183-4500 | Crimp cap | Silver aluminium | PTFE/silicone septum | 1000/pk | Bulk closure |
| 5181-1211 | Crimp cap | Silver aluminium | PTFE/silicone/PTFE septum | 25/pk | Trace work |
| 5183-4499 | Crimp cap | Silver aluminium | PTFE/silicone/PTFE septum | 1000/pk | Trace work, bulk |
| 5183-4498 | Crimp cap | Silver aluminium | PTFE/red rubber septum | 500/pk | Single injection |
| 5183-4757 | Inlet septum | Silicone, BTO | 11 mm, injection port | 50/pk | GC inlet to 400 °C |
| 186000307C | 2 mL screw neck | Clear, LCGC certified | Cap and preslit PTFE/silicone | 100/pk | LC/MS routine |
| 186000847C | 2 mL screw neck | Amber, LCGC certified | Cap and preslit PTFE/silicone | 100/pk | Light sensitive samples |
| 186000272C | 2 mL screw neck | Clear, LCGC certified | Cap and PTFE/silicone | 100/pk | LC routine |
| 186000846C | 2 mL screw neck | Amber, LCGC certified | Cap and PTFE/silicone | 100/pk | Light sensitive samples |
| 186000384C | Total recovery | Clear, LCGC certified | Cap and PTFE/silicone, 1 mL | 100/pk | Low volume samples |
| 186000305 | Screw cap | Blue | Preslit PTFE/silicone | 100/pk | Waters screw vial closure |
Key Features
Certified dimensions, not nominal – the 12 mm body and 32 mm height are held lot to lot, so the needle reaches the same depth in every tray position
Screw and crimp on one page – screw neck for LC and LC/MS, crimp neck for GC where volatile samples need a tighter seal
Amber for light sensitive work – the same geometry in amber glass, with a ceramic write-on spot for sample identity
Septa matched to the run – PTFE faced silicone for routine work, sandwich septa for trace analysis, BTO silicone for inlets at 400 °C
Preslit and plain – preslit septa reduce coring on trays that pierce the same cap many times
Convenience packs – vial, cap and septum under one part number when the lab does not want to fit closures by hand
Applications
The vial and the closure are chosen together with the instrument tray, so the application usually names both.
HPLC and LC/MS autosamplers – 2 mL screw neck vials with a 9 mm PTFE faced septum on the tray, capped at 12 mm
GC and GC/MS – 11 mm crimp neck vials for volatile samples, plus BTO inlet septa for the injection port
Stability and trace analysis – amber vials and sandwich septa where light exposure and silicone bleed both matter
Vials and closures are supplied alongside SUPERB PCB and SUPERB PCBA work when an analyser build moves from the board to the bench.
Sourcing and Cross-Reference
Two numbers decide whether a vial order is right: the neck finish and the certified status. A 9 mm screw vial will not take an 11 mm crimp cap, and an uncertified vial can sit half a millimetre out on height, which shows up as intermittent needle errors rather than a clean failure. For regulated work the certificate of analysis belongs in the same conversation as the price.
Vials, caps and septa are toleranced against each other. The septum seat depth and the cap skirt length are a pair, so a cap from one maker on a vial from another is where most autosampler problems begin. We quote matched sets and state which instrument family the set was certified against, which matters when the method is written around a named tray.
Septa are the part that reaches the detector. Red rubber is the cheapest and also the least resistant to coring, silicone is the general purpose choice, and the sandwich construction puts PTFE on both faces for samples that would otherwise pick up siloxanes. If the method quotes a temperature above 300 °C, the answer is usually an inlet septum rather than a vial septum.
Consumable kits for a new instrument are packed through SUPERB Assembly, so the tray arrives ready to load.
Q: Can you supply vials, caps and septa as one matched set for our autosampler tray?
A: Yes. SUPERB Tech quotes matched vial, cap and septum sets and names the tray family the dimensions were certified against.
Why Choose SUPERB for Autosampler Consumables
- Matched sets: vial, cap and septum quoted as one set, toleranced against each other
- Certified lots: certified vials and caps named by part number, so the certificate can be filed with the method
- Both neck finishes: 9 mm screw and 11 mm crimp on one page, with the caps and septa that fit them
- Septa by temperature: the bleed and temperature limit of each material is stated before you buy, not after
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Syringe Filters and Filter Paper, Calibration Buffers and Conductivity Standards, Sample Loops and Injection Loops, Quartz Flow Cells and Cuvettes, Peristaltic Pump Tubing and Pump Heads, Inline Static Mixers for Reagent Streams.