Contact Us

Autosampler Vials and Septa for HPLC

2 mL autosampler vials and closures for LC and GC trays. Screw neck 9 mm and crimp neck 11 mm, clear and amber, certified lots. PTFE silicone, sandwich and BTO septa, quoted as matched sets.
quote now

Product Specifications

Product Overview

A 2 mL vial looks like a commodity until the autosampler starts missing it. Three tolerances decide whether the needle finds the sample: the 12 mm body diameter that locates the vial in the tray, the 32 mm height that sets the needle depth, and the neck finish that holds the cap square. A vial that is half a millimetre out on height sits low, and the needle either bends or draws air rather than liquid.

The closure is half of the part. For LC and LC/MS work the wide opening screw vial with a 9 mm septum under a 12 mm cap is the common choice, because a screw cap can be re tightened and it reseals after several injections. For GC and GC/MS work the 11 mm crimp neck gives a tighter seal on volatile samples, a wider target for the needle, and a closure that cannot work loose in the tray. Both formats are on this page, with the caps and septa that match them.

Septa are ordered separately from caps and vials, and the material sets the temperature ceiling and the bleed level. PTFE faced silicone covers most LC and GC runs up to 200 °C. A PTFE silicone PTFE sandwich is used for trace work where silicone bleed reaches the detector. BTO inlet septa are a different part again: they sit in the injection port of a GC, not on the vial, and run to 400 °C.

Key Specifications

ParameterValueNotes
Vial format12 x 32 mm, 2 mLWide opening, 6 mm opening diameter
GlassClear or amber, 5% borosilicateType 1 Class for hydrolytic and acid resistance
Screw neck9 mm septum, 12 mm capLC and LC/MS trays
Crimp neck11 mm septum and capGC and GC/MS, volatile samples
Certified statusCertified lots, dimension checkedNeedle height and tray fit
Septa materialsPTFE/silicone, PTFE/silicone/PTFE, PTFE/red rubber, BTO siliconeTemperature and bleed differ
Septa temperature-40 to 200 °C for PTFE faced, 400 °C for BTO inlet septaPer material, check before use
Reseal after injectionYes for PTFE/silicone and sandwichNo for PTFE/red rubber
Pack sizes25, 100, 500 and 1000 per packConvenience packs combine vial and cap

Included Models and Order Codes

The first block is the LC family in screw neck, the second is the GC family in crimp neck, and the third is the septum and cap range that closes both. Part numbers with a write-on spot carry a ceramic patch for sample identity. Convenience packs are single part numbers that arrive with the cap and septum already fitted, which removes one assembly step in the lab.

Part NumberFormatGlass or ColourClosurePackUse
5182-07142 mL screw topClear, certified9 mm screw neck100/pkLC routine
5182-07152 mL screw topClear, write-on spot9 mm screw neck100/pkSample identity
5182-07162 mL screw topAmber, write-on spot9 mm screw neck100/pkLight sensitive samples
5183-20682 mL screw topClear, write-on spot9 mm screw neck1000/csBulk LC trays
5182-0717Screw capBlue polypropylenePTFE/red silicone septum100/pkScrew vial closure
5185-5820Screw capBlue polypropylenePTFE/red silicone septum500/pkScrew vial closure
5190-1599Screw capBlue polypropylenePTFE/red silicone septum1000/pkBulk closure
5182-0868Convenience packClear, write-on spotBlue cap, PTFE/silicone500/pkOne part number
5182-0864Convenience packClear, write-on spotBlue cap, PTFE/red rubber100/pkOne part number
5181-33752 mL crimp topClear, certified11 mm crimp neck100/pkGC routine
5182-05432 mL crimp topClear, write-on spot11 mm crimp neck100/pkSample identity
5181-33762 mL crimp topAmber, write-on spot11 mm crimp neck100/pkLight sensitive samples
5183-44912 mL crimp topClear11 mm crimp neck1000/csBulk GC trays
5182-0552Crimp capSilver aluminiumPTFE/silicone septum100/pkCrimp vial closure
5183-4500Crimp capSilver aluminiumPTFE/silicone septum1000/pkBulk closure
5181-1211Crimp capSilver aluminiumPTFE/silicone/PTFE septum25/pkTrace work
5183-4499Crimp capSilver aluminiumPTFE/silicone/PTFE septum1000/pkTrace work, bulk
5183-4498Crimp capSilver aluminiumPTFE/red rubber septum500/pkSingle injection
5183-4757Inlet septumSilicone, BTO11 mm, injection port50/pkGC inlet to 400 °C
186000307C2 mL screw neckClear, LCGC certifiedCap and preslit PTFE/silicone100/pkLC/MS routine
186000847C2 mL screw neckAmber, LCGC certifiedCap and preslit PTFE/silicone100/pkLight sensitive samples
186000272C2 mL screw neckClear, LCGC certifiedCap and PTFE/silicone100/pkLC routine
186000846C2 mL screw neckAmber, LCGC certifiedCap and PTFE/silicone100/pkLight sensitive samples
186000384CTotal recoveryClear, LCGC certifiedCap and PTFE/silicone, 1 mL100/pkLow volume samples
186000305Screw capBluePreslit PTFE/silicone100/pkWaters screw vial closure

Key Features

Certified dimensions, not nominal – the 12 mm body and 32 mm height are held lot to lot, so the needle reaches the same depth in every tray position

Screw and crimp on one page – screw neck for LC and LC/MS, crimp neck for GC where volatile samples need a tighter seal

Amber for light sensitive work – the same geometry in amber glass, with a ceramic write-on spot for sample identity

Septa matched to the run – PTFE faced silicone for routine work, sandwich septa for trace analysis, BTO silicone for inlets at 400 °C

Preslit and plain – preslit septa reduce coring on trays that pierce the same cap many times

Convenience packs – vial, cap and septum under one part number when the lab does not want to fit closures by hand

Applications

The vial and the closure are chosen together with the instrument tray, so the application usually names both.

HPLC and LC/MS autosamplers – 2 mL screw neck vials with a 9 mm PTFE faced septum on the tray, capped at 12 mm

GC and GC/MS – 11 mm crimp neck vials for volatile samples, plus BTO inlet septa for the injection port

Stability and trace analysis – amber vials and sandwich septa where light exposure and silicone bleed both matter

Vials and closures are supplied alongside SUPERB PCB and SUPERB PCBA work when an analyser build moves from the board to the bench.

Sourcing and Cross-Reference

Two numbers decide whether a vial order is right: the neck finish and the certified status. A 9 mm screw vial will not take an 11 mm crimp cap, and an uncertified vial can sit half a millimetre out on height, which shows up as intermittent needle errors rather than a clean failure. For regulated work the certificate of analysis belongs in the same conversation as the price.

Vials, caps and septa are toleranced against each other. The septum seat depth and the cap skirt length are a pair, so a cap from one maker on a vial from another is where most autosampler problems begin. We quote matched sets and state which instrument family the set was certified against, which matters when the method is written around a named tray.

Septa are the part that reaches the detector. Red rubber is the cheapest and also the least resistant to coring, silicone is the general purpose choice, and the sandwich construction puts PTFE on both faces for samples that would otherwise pick up siloxanes. If the method quotes a temperature above 300 °C, the answer is usually an inlet septum rather than a vial septum.

Consumable kits for a new instrument are packed through SUPERB Assembly, so the tray arrives ready to load.

Q: Can you supply vials, caps and septa as one matched set for our autosampler tray?

A: Yes. SUPERB Tech quotes matched vial, cap and septum sets and names the tray family the dimensions were certified against.

Why Choose SUPERB for Autosampler Consumables

  1. Matched sets: vial, cap and septum quoted as one set, toleranced against each other
  2. Certified lots: certified vials and caps named by part number, so the certificate can be filed with the method
  3. Both neck finishes: 9 mm screw and 11 mm crimp on one page, with the caps and septa that fit them
  4. Septa by temperature: the bleed and temperature limit of each material is stated before you buy, not after

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Syringe Filters and Filter Paper, Calibration Buffers and Conductivity Standards, Sample Loops and Injection Loops, Quartz Flow Cells and Cuvettes, Peristaltic Pump Tubing and Pump Heads, Inline Static Mixers for Reagent Streams.