Beam Dumps and Baffles for Stray Light Control
Product Specifications
Product Overview
Every optical bench has a beam that has to go somewhere. If it lands on a painted panel or a cable, the paint outgasses, the cable heats and the scatter comes back into the measurement. A beam dump is the part that absorbs the beam on purpose, on a surface that tolerates the power density and does not send it back.
The specification that matters is not the average power on its own. A 10 W beam focused to 0.5 mm carries 5 kW per cm2, and a block rated for 10 W of a 5 mm beam will not survive it. Both the average power and the power density have to be inside the rating, and for pulsed sources the energy density per pulse is the third number, because a nanosecond pulse damages a surface thermally in a way that a continuous beam never does.
The second job is stray light. Baffles and apertures inside a monochromator or a camera tube stop the rays that would otherwise reach the detector after two or three reflections. These are usually machined from blackened aluminium or lined with a black foil, and they are quoted from the drawing of the tube or the housing rather than from a catalogue, because the geometry is specific to the instrument.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Wavelength ranges | 200 nm to 3 um, 400 nm to 2.5 um, 1 to 12 um | Pick by laser type, not by price |
| CW rating | 5 W to 500 W | Liquid cooling raises the top of the range |
| Pulse rating | Up to 40 J per cm2 at 1064 nm, 10 ns, 10 Hz | Per model, check the note |
| Power density | Up to 25 kW per cm2 | Applies to the graphite blocks |
| Absorber material | Steel, graphite, ceramic | Graphite absorbs but runs hot |
| Entrance aperture | 35.6 x 17.8 mm up to 69 x 50 mm | The LB2 faceplate can be removed to widen it |
| Cooling | 1 L/min water at 25 C | LB2L and LB3L only |
| Coolant pressure | 145 psi | Water, ethanol or glycol mixes |
| Tubing | 1/4 in or 6 mm outer diameter | One touch fittings |
| Mounting | 8-32 or M4 taps, 30 mm and 60 mm cage | Post mount as standard |
| Operating temperature | 0 to 150 C at the cooled face | Housing runs hot above 45 W |
Included Models and Order Codes
The first block is the traps: enclosed absorbers that take the beam through a small aperture and lose it inside. The second is the flat blocks, which are simpler and cheaper where the beam is large or the power is low. The last two rows are the liquid cooled blocks, which are the answer above 80 W continuous, provided there is a water line and somewhere for the heat to go.
| Part Number | Type | Wavelength | CW Rating | Pulse Rating | Absorber | Mounting |
|---|---|---|---|---|---|---|
| BT600/M | Trap | 200 nm to 3 um | 80 W | 30 mJ per cm2 | Trap body | 30 mm cage, M4 post |
| BT610/M | Trap | 400 nm to 2.5 um | 30 W | 40 J per cm2 | Trap body | 30 mm cage, M4 post |
| BT620/M | Trap | 1 to 12 um | 50 W | 25 J per cm2 | Trap body | 30 mm cage, M4 post |
| BTC30 | Quick release trap | 200 nm to 3 um | 5 W | 30 mJ per cm2 | Trap body | 30 mm cage |
| LB1/M | Block | 400 nm to 2 um | 10 W | Not rated | Steel | Post, 3 in included |
| LB2/M | Block | 1 to 12 um | 80 W | 25 J per cm2 | Graphite | 60 mm cage, M4 post |
| LB2L/M | Liquid cooled block | 1 to 12 um | 500 W | 25 J per cm2 | Graphite | 60 mm cage, M4 post |
| LB3L | Liquid cooled block | 1 to 12 um | 100 W | 25 J per cm2 | Graphite | 30 mm cage |
Key Features
Average power and power density both stated – a block rated for 10 W of a 5 mm beam is not rated for the same 10 W focused to 0.5 mm
Pulse rating in energy density – joules per cm2 at 1064 nm, 10 ns, 10 Hz, which is the number a pulsed source needs
Trap or block by geometry – an enclosed trap for a collimated beam, a flat block where the beam is large or divergent
Liquid cooling where it is needed – 500 W continuous on the LB2L at 1 L/min, with the fittings and the pressure rating given
Cage and post mounting – 30 mm and 60 mm cage taps, so the dump sits on the same rails as the rest of the bench
Housing temperature called out – the case runs above 100 C at the top of the range, which decides where it can be mounted
Applications
A dump is fitted at the end of a beam path, so the application is usually described by the source and the bench around it.
Laser and LED bench safety – a trap at the end of a collimated path, with the aperture matched to the beam and the cage carrying the rest of the optics
Raman and fluorescence probes – a block behind the sample where the transmitted excitation has to disappear without scattering back into the collection path
High power curing and cutting heads – a liquid cooled block on a water line, sized for the continuous power and the power density at the focus
Bench hardware ships with the SUPERB PCB and SUPERB PCBA builds that drive the laser or lamp, so the optical and electrical sides of a bench arrive together.
Sourcing and Cross-Reference
Two mistakes account for most damaged dumps. The first is using the average power rating as if it were a power density rating, which fails as soon as a lens concentrates the beam. The second is mounting a graphite block on a plastic bracket; the absorber is fine and the bracket melts. Both are avoided by quoting the beam diameter at the dump along with the power.
For pulsed sources the energy density is the limit and the repetition rate only matters through the average. A block that takes 25 J per cm2 at 10 Hz is not rated for 5 J per cm2 at 50 Hz just because the energy per pulse is lower; the average power has to be inside the CW rating as well, and both numbers have to pass.
Baffles inside an instrument are a drawing job rather than a catalogue one. The usual request is a set of aperture plates that fit inside a tube, blackened on the beam side and spaced so that no straight line reaches the detector wall. We quote those from the tube bore, the plate spacing and the clear aperture, in aluminium or stainless, with the finish stated, because a glossy plate defeats the purpose.
Dump, bracket and coolant fittings are kitted through SUPERB Assembly against the bench layout drawing.
Q: Can you supply a beam dump rated for 25 W of a 3 mm beam at 1064 nm, with cage mounting?
A: Yes. SUPERB Tech quotes the dump against the beam diameter and the pulse width as well as the average power, and states the housing temperature.
Why Choose SUPERB for Beam Dumps and Baffles
- Two ratings, not one: average power and power density given together, so a focused beam is not overlooked
- Pulse data in the right unit: energy density per pulse at a stated wavelength and pulse width
- Cooling sized honestly: flow, pressure and tube size given with the 500 W figure
- Baffles quoted from the drawing: plate spacing, bore and finish agreed against the instrument, not guessed
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Neutral Density Filters and Reference Standards, Optical Slits and Apertures, Lenses and Mirrors for Optical Benches, Optical Windows and Sapphire Discs, Dichroic Filters and Beam Splitters, Lamp Housings and Shutters.