Contact Us

Beam Dumps and Baffles for Stray Light Control

Where the beam ends, on purpose. Traps and blocks from 200 nm to 12 um, 5 W to 500 W CW. Graphite, steel and ceramic absorbers, cage or post mounted.
quote now

Product Specifications

Product Overview

Every optical bench has a beam that has to go somewhere. If it lands on a painted panel or a cable, the paint outgasses, the cable heats and the scatter comes back into the measurement. A beam dump is the part that absorbs the beam on purpose, on a surface that tolerates the power density and does not send it back.

The specification that matters is not the average power on its own. A 10 W beam focused to 0.5 mm carries 5 kW per cm2, and a block rated for 10 W of a 5 mm beam will not survive it. Both the average power and the power density have to be inside the rating, and for pulsed sources the energy density per pulse is the third number, because a nanosecond pulse damages a surface thermally in a way that a continuous beam never does.

The second job is stray light. Baffles and apertures inside a monochromator or a camera tube stop the rays that would otherwise reach the detector after two or three reflections. These are usually machined from blackened aluminium or lined with a black foil, and they are quoted from the drawing of the tube or the housing rather than from a catalogue, because the geometry is specific to the instrument.

Key Specifications

ParameterValueNotes
Wavelength ranges200 nm to 3 um, 400 nm to 2.5 um, 1 to 12 umPick by laser type, not by price
CW rating5 W to 500 WLiquid cooling raises the top of the range
Pulse ratingUp to 40 J per cm2 at 1064 nm, 10 ns, 10 HzPer model, check the note
Power densityUp to 25 kW per cm2Applies to the graphite blocks
Absorber materialSteel, graphite, ceramicGraphite absorbs but runs hot
Entrance aperture35.6 x 17.8 mm up to 69 x 50 mmThe LB2 faceplate can be removed to widen it
Cooling1 L/min water at 25 CLB2L and LB3L only
Coolant pressure145 psiWater, ethanol or glycol mixes
Tubing1/4 in or 6 mm outer diameterOne touch fittings
Mounting8-32 or M4 taps, 30 mm and 60 mm cagePost mount as standard
Operating temperature0 to 150 C at the cooled faceHousing runs hot above 45 W

Included Models and Order Codes

The first block is the traps: enclosed absorbers that take the beam through a small aperture and lose it inside. The second is the flat blocks, which are simpler and cheaper where the beam is large or the power is low. The last two rows are the liquid cooled blocks, which are the answer above 80 W continuous, provided there is a water line and somewhere for the heat to go.

Part NumberTypeWavelengthCW RatingPulse RatingAbsorberMounting
BT600/MTrap200 nm to 3 um80 W30 mJ per cm2Trap body30 mm cage, M4 post
BT610/MTrap400 nm to 2.5 um30 W40 J per cm2Trap body30 mm cage, M4 post
BT620/MTrap1 to 12 um50 W25 J per cm2Trap body30 mm cage, M4 post
BTC30Quick release trap200 nm to 3 um5 W30 mJ per cm2Trap body30 mm cage
LB1/MBlock400 nm to 2 um10 WNot ratedSteelPost, 3 in included
LB2/MBlock1 to 12 um80 W25 J per cm2Graphite60 mm cage, M4 post
LB2L/MLiquid cooled block1 to 12 um500 W25 J per cm2Graphite60 mm cage, M4 post
LB3LLiquid cooled block1 to 12 um100 W25 J per cm2Graphite30 mm cage

Key Features

Average power and power density both stated – a block rated for 10 W of a 5 mm beam is not rated for the same 10 W focused to 0.5 mm

Pulse rating in energy density – joules per cm2 at 1064 nm, 10 ns, 10 Hz, which is the number a pulsed source needs

Trap or block by geometry – an enclosed trap for a collimated beam, a flat block where the beam is large or divergent

Liquid cooling where it is needed – 500 W continuous on the LB2L at 1 L/min, with the fittings and the pressure rating given

Cage and post mounting – 30 mm and 60 mm cage taps, so the dump sits on the same rails as the rest of the bench

Housing temperature called out – the case runs above 100 C at the top of the range, which decides where it can be mounted

Applications

A dump is fitted at the end of a beam path, so the application is usually described by the source and the bench around it.

Laser and LED bench safety – a trap at the end of a collimated path, with the aperture matched to the beam and the cage carrying the rest of the optics

Raman and fluorescence probes – a block behind the sample where the transmitted excitation has to disappear without scattering back into the collection path

High power curing and cutting heads – a liquid cooled block on a water line, sized for the continuous power and the power density at the focus

Bench hardware ships with the SUPERB PCB and SUPERB PCBA builds that drive the laser or lamp, so the optical and electrical sides of a bench arrive together.

Sourcing and Cross-Reference

Two mistakes account for most damaged dumps. The first is using the average power rating as if it were a power density rating, which fails as soon as a lens concentrates the beam. The second is mounting a graphite block on a plastic bracket; the absorber is fine and the bracket melts. Both are avoided by quoting the beam diameter at the dump along with the power.

For pulsed sources the energy density is the limit and the repetition rate only matters through the average. A block that takes 25 J per cm2 at 10 Hz is not rated for 5 J per cm2 at 50 Hz just because the energy per pulse is lower; the average power has to be inside the CW rating as well, and both numbers have to pass.

Baffles inside an instrument are a drawing job rather than a catalogue one. The usual request is a set of aperture plates that fit inside a tube, blackened on the beam side and spaced so that no straight line reaches the detector wall. We quote those from the tube bore, the plate spacing and the clear aperture, in aluminium or stainless, with the finish stated, because a glossy plate defeats the purpose.

Dump, bracket and coolant fittings are kitted through SUPERB Assembly against the bench layout drawing.

Q: Can you supply a beam dump rated for 25 W of a 3 mm beam at 1064 nm, with cage mounting?

A: Yes. SUPERB Tech quotes the dump against the beam diameter and the pulse width as well as the average power, and states the housing temperature.

Why Choose SUPERB for Beam Dumps and Baffles

  1. Two ratings, not one: average power and power density given together, so a focused beam is not overlooked
  2. Pulse data in the right unit: energy density per pulse at a stated wavelength and pulse width
  3. Cooling sized honestly: flow, pressure and tube size given with the 500 W figure
  4. Baffles quoted from the drawing: plate spacing, bore and finish agreed against the instrument, not guessed

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Neutral Density Filters and Reference Standards, Optical Slits and Apertures, Lenses and Mirrors for Optical Benches, Optical Windows and Sapphire Discs, Dichroic Filters and Beam Splitters, Lamp Housings and Shutters.