Neutral density filters and certified references for photometers. Absorptive ND filters in optical densities from 1.0 to 4.0 on 25 mm mounts. Schott NG glass references certified at 440, 465, 546.1, 590 and 635 nm. Holmium and didymium filters for wavelength checks, with NIST traceability.
quote now

Product Specifications

Product Overview

Two different jobs are done with a grey filter. The first is attenuation: dropping the light level so a detector stays in its linear range, which is what a neutral density filter does. The second is qualification: proving that the absorbance scale and the wavelength scale are right, which needs a certified reference and a certificate that names the wavelengths. Both are on this page, and they are not interchangeable.

An absorptive ND filter attenuates across a band rather than at a line, so it does not create the interference fringes that a thin metal film can add to a spectrum. The optical density is quoted at a stated wavelength, and the tolerance widens at higher density: an OD 4.0 filter is a very small transmission, so a small manufacturing spread becomes a large relative uncertainty. That is why high density filters are used for stray light checks rather than for quantitative work.

A photometric reference is a different article. It has a certificate tied to NIST practice, it is measured at a stated spectral bandwidth, and it is mounted stress free so the glass does not become birefringent in its holder. The references listed here follow the wavelengths in the NIST technical specification for spectrophotometric reference materials, which means the values in the certificate can be compared with the values in the method.

Key Specifications

ParameterValueNotes
ND filter materialSchott NG glass or metal on quartzAbsorptive, low fringe
Optical density range1.0 to 4.025 mm mounted filters
Absorbance range of references0.04 A to 3.5 ANineteen filters in the standard format
Certified wavelengths440, 465, 546.1, 590, 635 nmVisible reference set
Certified bandwidth1.0 nmOther bandwidths on request
Reference materialNG type glass, stress free mountAnodised aluminium holder
TraceabilityNIST SP 260-140SRM 930e, 1930 and 2930 equivalents
Wavelength referencesHolmium 360-640 nm, didymium 430-890 nmBonded to a 1 A neutral filter
ND blocking range400 to 650 nmAbsorptive 25 mm filters
Surface quality40-20 scratch digMounted ND filters
Filter diameter25 mmMounted in an SM1 thread

Included Models and Order Codes

The first group is attenuation, the second and third are qualification. On the Starna glass filters the catalogue number carries the nominal transmission, so 1N is 10% and 9N is 90%, and the same numbers combine into the SRM equivalent sets. Metal on quartz parts use the RM- prefix because they are reference materials rather than working filters.

Part NumberTypeNominal ValueWavelengthsMountUse
NE10AAbsorptive ND filterOD 1.0, 10% T400 to 650 nm25 mm, SM1 threadAttenuation
NE20AAbsorptive ND filterOD 2.0, 1% TVisible25 mm, SM1 threadAttenuation
NE30AAbsorptive ND filterOD 3.0, 0.1% TVisible25 mm, SM1 threadAttenuation
NE40AAbsorptive ND filterOD 4.0, 0.01% TVisible25 mm, SM1 threadStray light check
1NNG glass reference10% T, 1.0 A440 to 635 nmAluminium holderAbsorbance check
2NNG glass reference20% T, 0.7 A440 to 635 nmAluminium holderAbsorbance check
3NNG glass reference30% T, 0.5 A440 to 635 nmAluminium holderAbsorbance check
5NNG glass reference50% T, 0.3 A440 to 635 nmAluminium holderAbsorbance check
9NNG glass reference90% T, 0.04 A440 to 635 nmAluminium holderAbsorbance check
RM-1QMetal on quartz reference10% T, 1.0 A250 to 635 nmAluminium holderUV and visible
RM-3QMetal on quartz reference30% T, 0.5 A250 to 635 nmAluminium holderUV and visible
RM-5QMetal on quartz reference50% T, 0.3 A250 to 635 nmAluminium holderUV and visible
RM-9QMetal on quartz reference90% T, 0.04 A250 to 635 nmAluminium holderUV and visible
RM-Q3Metal on quartz reference3% T, 1.5 A250 to 635 nmAluminium holderUV and visible
RM-Q1Metal on quartz reference1% T, 2.0 A250 to 635 nmAluminium holderUV and visible
RM-HGHolmium glass filterWavelength reference360 to 640 nmAluminium holderWavelength check
RM-DGDidymium glass filterWavelength reference430 to 890 nmAluminium holderWavelength check
RM-HG/1NDHolmium with neutral filterWavelength and 1 A360 to 640 nmAluminium holderOne pass check
RM-DG/1NDDidymium with neutral filterWavelength and 1 A430 to 890 nmAluminium holderOne pass check
1N3N5DHGQualification set1.0, 0.5, 0.25 A plus holmium440 to 635 nmHolder setInstrument qualification
RM-1N2N3NSRM 930e equivalent set10, 20, 30% T440 to 635 nmHolder setAbsorbance scale
RM-N1N35NSRM 1930 equivalent set1, 3, 50% T440 to 635 nmHolder setAbsorbance scale
RM-1Q3Q9QSRM 2013a equivalent set10, 30, 90% T250 to 635 nmHolder setUV and visible scale

Key Features

Absorptive, not reflective – NG glass attenuates through the bulk, so it does not add interference fringes to a spectrum

Four densities – OD 1.0 to 4.0 covers routine attenuation through to a stray light check

Certified at five wavelengths – 440, 465, 546.1, 590 and 635 nm match the wavelengths used in pharmacopoeial methods

One nanometre bandwidth – the certificate figures are measured at the bandwidth the method specifies

Stress free mounting – the glass sits in an aluminium holder without strain, so it does not become birefringent

Holmium and didymium – rare earth glass gives sharp peaks for a wavelength accuracy check in the visible

Bonded 1 A versions – a rare earth filter bonded to a neutral filter checks wavelength and absorbance in one pass

SRM equivalent sets – sets matched to SRM 930e, 1930 and 2013a let a lab work to the published specification

Applications

Attenuation and qualification are used at different points in an instrument check, so the part follows the check.

Spectrophotometer qualification – a set of glass references checks absorbance accuracy, linearity and wavelength accuracy in one sequence

Stray light and linearity checks – high density filters push the detector into the range where stray light shows up

Detector and lamp level setting – an absorptive filter drops the light level without changing the spectrum shape

Photometric standards are supplied alongside SUPERB PCB and SUPERB PCBA work when an analyser build needs its detector board and its qualification set together.

Sourcing and Cross-Reference

A working filter and a reference are ordered for different reasons, and mixing them is a common mistake. An OD 2.0 filter will attenuate light, but without a certificate naming the wavelength and bandwidth its absorbance value cannot be used to qualify an instrument. If the purpose is qualification, the certificate is the part that matters.

For references, three details decide whether a certificate is usable: the wavelengths, the spectral bandwidth, and the mounting. A value measured at 5 nm bandwidth cannot be compared with a method written for 1 nm, and a filter clamped in a screw holder can read differently from one mounted stress free. Both are stated on the parts listed here.

Replacement references are usually bought as a set rather than a single filter, because linearity is checked by comparing several values. We quote the individual filters and the sets that match the published SRM specifications, so a lab can either extend an existing set or buy into a specification it already works to.

Reference sets that ship with an instrument are packed through SUPERB Assembly with the detector board they qualify.

Q: Can you supply a certified reference set that matches the specification our method quotes?

A: Yes. SUPERB Tech quotes certified sets against the SRM specification named in the method and states the bandwidth on the certificate.

Why Choose SUPERB for Photometric Standards

  1. Certificate details stated: wavelengths and bandwidth are given, because a value without them cannot qualify an instrument
  2. Sets and single filters: a set can be extended one filter at a time instead of replaced
  3. Absorptive working filters: bulk absorbing glass attenuates without adding fringes to the spectrum
  4. Traceability named: the NIST specification behind each set is quoted so it can be checked against the method

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Bandpass and Interference Filters, Optical Windows and Sapphire Discs, Calibration Buffers and Conductivity Standards, Quartz Flow Cells and Cuvettes, Dichroic Filters and Beam Splitters, Obsolete Part Cross Reference Hub.