Contact Us

Optical Filter Mounts and Lens Holders

Mounts that hold a lens where the beam expects it, and filter holders that let it be swapped. Fixed holders for 12.7, 25.4 and 50.8 mm optics with SM05, SM1 and SM2 threads. Kinematic and rotation mounts for alignment, drop in holders for quick filter changes.
quote now

Product Specifications

Product Overview

A mount is a mechanical decision that shows up as an optical error. The optic has to sit square to the beam, at a known height above the table, and it has to stay there when a filter is changed next to it. That is why the thread standard matters more than the brand: SM05, SM1 and SM2 threads at 0.535, 1.035 and 2.035 inch are what let a lens tube, a filter holder and a cage plate from three suppliers fit together on one bench.

Fixed holders cover most of the work. A retaining ring traps the optic against a machined lip, and the clear aperture is slightly smaller than the optic, so a 25.4 mm lens sits in a 22.9 mm opening. The maximum thickness is the number that catches people out: a 7.1 mm limit fits a plano convex singlet but not a cemented doublet, and the answer is either a deeper holder or a lens tube in front of it.

The other half of this family is about access. A drop in filter holder lets a 25.4 mm filter be squeezed into a spring clamp and removed again without touching the rest of the setup, which is what a filter wheel cannot do when only one position changes. A kinematic mount adds two adjusters for tip and tilt, and a rotation mount adds a graduated ring for polarisers and wave plates. Each step buys a degree of freedom and costs stability, so the plain holder is still the right answer wherever nothing has to move.

Key Specifications

ParameterValueNotes
Optic diameters12.7, 25.4 and 50.8 mm, plus 2 to 10 mm adaptersRound optics, square filters in the drop in holders
Thread standardsSM05 0.535-40, SM1 1.035-40, SM2 2.035-40External and internal versions on the same family
Max optic thickness5.0 mm at 12.7 mm, 7.1 mm at 25.4 mm, 9.1 mm at 50.8 mmThin optic cells reach 3.5 mm and stop there
Clear aperture11.0, 22.9 and 48.5 mmMeasured without a retaining ring
Optical axis height16.0, 22.1 and 34.5 mm above the postNewport A line holders sit at 25.4 and 31.8 mm
Post mounting8-32, M4 and M6 taps and counterboresRight or left handed orientation on kinematic mounts
Kinematic rangePlus or minus 4 degrees at 25.4 mm, plus or minus 3 degrees at 50.8 mmTwo or three adjusters
Adjuster resolution8 mrad (0.5 degree) per turn at 25.4 mm, 5 mrad at 50.8 mm1/4-80 threads
Rotation360 degrees continuous with 2 degree graduationsLocking screw on the rotation ring
Drop in filter holder25.4 mm round or square, up to 5 mm thickSpring loaded v groove clamp
Filter mount inside a tubeUnmounted up to 3.5 mm, mounted 3.5 to 6.3 mmClear aperture 21 mm, body 33.3 mm OD
Retaining ringsSM05RR, SM1RR, SM2RRIncluded with most holders, sold separately for some

Included Models and Order Codes

The table runs from the plainest part to the most adjustable. The first block is fixed holders in three sizes, the second is filter holders that take a filter in and out without tools, and the third is kinematic and rotation mounts where alignment has to be trimmed after assembly. Newport A line holders are listed at the end because their 31.8 mm axis height is fixed and does not match the Thorlabs 22.1 mm.

Part NumberOptic SizeMax ThicknessClear ApertureAxis HeightMountingFunction
LMR05(/M)12.7 mm5.0 mm11.0 mm16.0 mm8-32 or M4 tapFixed holder, SM05 thread
LMR1(/M)25.4 mm7.1 mm22.9 mm22.1 mm8-32 or M4 tapFixed holder, SM1 thread
LMR1S(/M)25.4 mm7.1 mm23.0 mm22.1 mm8-32 or M4 tapFixed holder, internal and external SM1
LMR2S(/M)50.8 mm9.1 mm48.5 mm34.5 mm8-32 or M4 tapFixed holder, internal and external SM2
SMR1(/M)25.4 mm6.1 mm25.6 mm22.1 mm8-32 or M4 tapFixed holder, ring sold separately
SM1QU25.4 mm unmounted filter3.5 mm21 mmIn lineFits an SM1 lens tubeDrop in filter mount, 33.3 mm body
SM1QP25.4 mm mounted filter3.5 to 6.3 mm21 mmIn lineFits an SM1 lens tubeDrop in filter mount for mounted filters
KM10025.4 mm3 mm minimumOptic bore22.1 mm nominal8-32 or M4 counterboreKinematic, plus or minus 4 degrees
KM100T25.4 mm3.5 mmOptic bore22.1 mm nominal8-32 or M4 counterboreKinematic cell for thin optics
KM100CP(/M)25.4 mm3 mm minimumOptic boreCentred on the post8-32 or M4 threadedRear loaded kinematic mount
KM20050.8 mm4 mm minimumOptic bore39.6 mm8-32 or M4 counterboreKinematic, plus or minus 3 degrees
KS1RS25.4 mm11.9 mmOptic bore22.1 mm nominal8-32 or M4 counterboreKinematic plus 360 degree rotation
KC1T(/M)25.4 mm5.8 mmOptic boreCage centred30 mm cage or postThree adjuster kinematic cell
LMRA55 mm optic2.2 mm3.8 mmIn an SM05 mountSM05 boreAdapter for small optics
LMRA1010 mm optic2.5 mm8.8 mmIn an SM05 mountSM05 boreAdapter, 18 mm outer diameter
LH-1A25.4 mm7 mm edge22.9 mm31.8 mm8-32 tapNewport A line fixed holder
M-LH-1A25.4 mm7 mm edge22.9 mm31.8 mmM4 tapMetric version of the same holder
LH-0.5A12.7 mmEdge thin optic10.9 mm25.4 mmM4 tapNewport small holder
LH-2A50.8 mmEdge thin optic47.5 mm44.5 mmM4 tapNewport 2 in holder
FH-1S25.4 mm round or square filter5 mmFilter faceNot applicable8-32 and M4Drop in spring clamp filter holder

Key Features

One thread family – SM05, SM1 and SM2 bores take lens tubes, cage plates and adapters without an extra ring

Clear aperture stated – 22.9 mm on a 25.4 mm holder is quoted, so a lens is not ordered that overfills the opening

Thickness limit per part – 7.1 mm on LMR1 and 3.5 mm on KM100T, which decides between a holder and a tube

Filters changed without tools – a spring clamp or a drop in cell takes a filter out while the rest of the bench stays aligned

Kinematic when it is needed – plus or minus 4 degrees at 25.4 mm for beam steering, with the plain holder kept everywhere else

Rotation for polarisers – a graduated ring with a locking screw, 2 degrees per division on the KS1RS

Applications

These parts are bought with the optic, not after it, because the holder sets the thickness, the height and the thread that everything downstream has to match.

Spectrometer front ends – SM1 holders and drop in filter cells in front of a slit, with the filter changed between methods

Machine vision filters – 25.4 mm square filters in a spring clamp holder on a camera lens, swapped between bandpass ranges

Laser beam steering – a kinematic 25.4 mm mount on a post, adjusted after the laser is on and then locked

Mounts and holders ship alongside SUPERB PCB and SUPERB PCBA work when an instrument build moves from the board to the optics.

Sourcing and Cross-Reference

The two numbers worth checking before an order are the optic thickness and the axis height. A holder that takes a 7.1 mm optic will not close on a 9 mm mounted filter, and a 22.1 mm axis height against a 31.8 mm holder in the same bench leaves a step that has to be shimmed. We quote the height with the part so the bench can be laid out on paper first.

Adapters are the quiet cost. A 5 mm or 10 mm optic needs an SM05 adapter before it can sit in a standard holder, and a 50.8 mm optic needs SM2 parts all the way along the path. Mixing one size into a bench built on another size costs more in adapters than the larger holder would have cost, which is worth saying before a drawing is fixed.

For filter work, the choice is between a holder and a wheel. A wheel changes position by motor or by hand but cannot take a filter outside its carrier, and a drop in holder takes any 25.4 mm filter at once. Where a method needs three fixed ranges at speed, we quote the wheel, and where it needs one filter changed between samples, the spring clamp is cheaper and faster.

Optical kits for a new instrument are packed through SUPERB Assembly, so each holder arrives with its retaining ring and label in one bag.

Q: Can you supply a 25.4 mm kinematic mount together with a drop in filter holder that fits the same SM1 thread?

A: Yes. SUPERB Tech quotes the mount, the retaining ring and any adapter together, and states the optic thickness it closes on before the order is placed.

Why Choose SUPERB for Mounts and Filter Holders

  1. Threads and heights on the page: SM05, SM1 and SM2 parts are listed with the axis height that goes with them
  2. Thickness limits stated: each holder names the thickest optic it closes on, so a mounted filter is not ordered blind
  3. Adapters for small optics: 5 and 10 mm adapters listed with the holders they fit, instead of being found later
  4. Two maker families: Thorlabs and Newport A line holders quoted side by side when a bench already uses one height

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Lenses and Mirrors for Optical Benches, Filter Wheels and Automated Changers, Dichroic Filters and Beam Splitters, Neutral Density Filters and Photometric Standards, Optical Slits and Apertures, Optical Windows and Sapphire Discs.