Tube Fittings and Ferrules for Reagent Lines
Product Specifications
Product Overview
A reagent line that drips is almost never a pump problem. It is a ferrule that was tightened twice on the same tubing, a nut that does not match the port, or a fitting reused after the tube was cut back. On an analyser the leak shows up as a drifting baseline or a bubble in the cell, and by then the fitting has usually been replaced once already with the wrong type.
This page separates the two things that are ordered together: the nut and the ferrule. Flangeless fittings use an ETFE ferrule that seals on the outside of the tube and can be reused a few times; two piece fingertight fittings use a PEEK or stainless ferrule that grips harder and holds to 7000 psi and above. Both are listed with the port they fit, because a 1/4-28 flat bottom nut will not seal in a 10-32 coned port however hard it is turned.
Pressure rating is the second trap. A standard flangeless fitting with an ETFE ferrule is rated to 2000 psi, while the same style in 1/8 inch tubing is rated to 500 psi because of the larger ferrule area. Mixing the two on one manifold leaves the 1/8 inch line as the weak point, and the leak appears at the fitting rather than at the pump.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Port threads | 1/4-28 flat bottom, 10-32 coned, M6 flat bottom | Chosen to match the port, not the tube |
| Tubing outside diameter | 1/16 in and 1/8 in | Also 1/32 in on some nuts |
| Nut materials | PEEK, ETFE, Delrin, PPS, stainless steel | Colour codes the ferrule size |
| Ferrule materials | ETFE, PEEK, stainless steel | ETFE is reusable, PEEK grips harder |
| Flangeless rating | 2000 psi (138 bar) | 1/16 in with ETFE ferrule |
| 1/8 in fitting rating | 500 psi (34 bar) | Larger ferrule area lowers the rating |
| Two piece rating | 7000 to 9000 psi (483 to 620 bar) | Fingertight PEEK or stainless |
| One piece rating | 1000 psi (69 bar) | Super flangeless, 1/16 in |
| Small valve ferrule | 2500 psi (172 bar) | P-240 for 1/4-28 or 10-32 |
| Head styles | Knurl, headless knurl, hex, FlushNut | Headless for tight manifolds |
Included Models and Order Codes
Nuts and ferrules are listed in separate groups so a worn ferrule can be replaced without buying a full fitting. The number after the dash on an XP part is the pack size, where x is ten pieces. Where a fitting is supplied with a ferrule the included ferrule is named, because the pressure rating belongs to the pair and not to the nut.
| Part Number | Type | Port | Tubing OD | Included Ferrule | Max Pressure |
|---|---|---|---|---|---|
| XP-230 | Flangeless fitting | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-235 | Flangeless fitting, short | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-201 | Flangeless fitting | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-202 | Flangeless fitting, red | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-218 | Flangeless fitting, ETFE | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-245 | Flangeless fitting, PFA | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-286 | Flangeless fitting, headless | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XF-358 | Flangeless fitting, FlushNut | 1/4-28 flat bottom | 1/16 in | P-200 ETFE | 2000 psi |
| XP-330 | Flangeless fitting | 1/4-28 flat bottom | 1/8 in | P-300 ETFE | 500 psi |
| XP-335 | Flangeless fitting, short | 1/4-28 flat bottom | 1/8 in | P-300 ETFE | 500 psi |
| P-200 | Replacement ferrule | 1/4-28 flat bottom | 1/16 in | Not applicable | 2000 psi |
| P-200N | Replacement ferrule, natural | 1/4-28 flat bottom | 1/16 in | Not applicable | 2000 psi |
| P-240 | Ferrule for small valve | 1/4-28 or 10-32 | 1/16 in | Not applicable | 2500 psi |
| P-250-10 | Super flangeless ferrule | 1/4-28 flat bottom | 1/16 in | Not applicable | 2500 psi |
| P-259-10 | Super flangeless ferrule, ETFE | 1/4-28 flat bottom | 1/16 in | Not applicable | 1350 psi |
| F-190-10 | SealTight two piece fitting | 10-32 coned | 1/16 in | F-192 PEEK | 7000 to 9000 psi |
| F-192-10 | SealTight replacement ferrule | 10-32 or M6 coned | 1/16 in | Not applicable | 7000 to 9000 psi |
Key Features
Nut and ferrule separate – a worn ferrule can be replaced on its own instead of scrapping a fitting that is still good
ETFE seals and reseals – the flangeless ferrule can be retightened a few times, which suits lines that are opened during service
Colour coded nuts – the nut colour identifies the ferrule size, so a 1/16 inch line is not fitted with a 1/8 inch ferrule by mistake
Headless option – a headless knurl fits manifolds where there is no room to swing a full knob
Two pressure classes – 2000 psi for 1/16 inch and 500 psi for 1/8 inch are stated apart so one line does not set the limit for another
7000 psi two piece set – the PEEK and stainless SealTight pair holds high pressure without a flanging tool
Small valve ferrule – P-240 seats in a 1/4-28 or 10-32 valve port where a standard ferrule bottoms out
Ten piece packs – packs of ten match the way fittings are actually consumed on a service visit
Applications
Fittings are chosen by port and tube, then by the pressure the line has to hold.
HPLC and reagent manifolds – flangeless fittings connect PEEK tubing to valves and tees without a flanging tool
Analyser sample and waste lines – colour coded nuts keep the 1/16 and 1/8 inch runs from being mixed during service
High pressure LC paths – two piece fingertight sets hold to 7000 psi and above on narrow bore columns
Fluidic fittings are supplied with SUPERB PCB and SUPERB PCBA orders when an analyser build needs both the manifold and its control board.
Sourcing and Cross-Reference
Every fitting order starts with the port. 1/4-28 flat bottom, 10-32 coned and M6 flat bottom are not interchangeable, and a nut that matches the thread but not the seat will tighten and still leak. We ask for the port and the tube outside diameter, and only then pick the style.
The ferrule decides the pressure rating, not the nut. An ETFE ferrule in a 1/16 inch fitting holds 2000 psi; the same nut with a PEEK ferrule from a two piece set holds 7000 psi and above. Substituting one for the other to save cost moves the weak point, and it usually moves it to a line that is harder to reach.
Because ferrules are the part that wears, we quote them in packs alongside the nuts and name the included ferrule on every fitting line. That way a repeat order can be a ferrule pack rather than a full fitting, which is what most service kits actually need.
Manifold plates that carry these fittings are assembled through SUPERB Assembly before the line is pressure tested.
Q: Can you supply the ferrule on its own when only that part has worn out?
A: Yes. SUPERB Tech supplies ferrules as separate parts, so a worn ferrule does not mean a new fitting.
Why Choose SUPERB for Fluidic Fittings
- Port matched first: the nut is selected on thread and seat, which is where leaks begin
- Rating per pair: pressure is quoted for the nut and ferrule together, not for the nut alone
- Ferrules sold apart: a worn ferrule can be replaced without buying the fitting again
- Consistent colour coding: nut colour and ferrule size stay paired so a service kit cannot be assembled wrongly
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Needle and Metering Valves, Inline Filters and Frits, Sample Loops and Injection Loops, Peristaltic Pump Tubing and Pump Heads, Rotary and Injection Valves, Obsolete Part Cross Reference Hub.