Contact Us

RTD and Thermocouple Probes for Analyser Blocks

Temperature probes built for a block, not for a wall. Pt100 class A in 2, 3 or 4 wire, type K and J thermocouples in class 1. 304 and 316 sheath, M8 to G1/2 threads, sealed or exposed junction.
quote now

Product Specifications

Product Overview

The temperature at a reaction block, a column oven or a sample cell is usually measured through a small port, into a metal body that is hotter than the air around it. That geometry decides more about the reading than the sensor inside: a 3 mm sheath responds in seconds, a 6 mm sheath lasts longer, and a probe that touches the bottom of a blind port reads the block while a probe hanging in the gas space reads nothing useful.

Two sensor families cover the job. A Pt100 element changes resistance by roughly 0.385 ohms per ohm per degree and is linear enough to be read without correction across minus 100 to 400 C, which is why it is the default for block temperature. A type K thermocouple produces about 41 uV per degree and reaches 1149 C in an Inconel sheath, which is the choice for heaters, hot gas lines and anything a Pt100 cannot survive.

The lead connection is where most installations go wrong. A two wire Pt100 adds the lead resistance to the reading, which shows up as a fixed offset of a degree or more. Three wire compensation removes most of it and four wire removes all of it, so the probe should be chosen with the input the controller actually has, not the other way round.

Key Specifications

ParameterValueNotes
RTD elementPt100, alpha 0.00385, class A or 1/3 DINPt1000 and 2 wire versions available
Wiring2, 3 or 4 wire3 wire compensates lead resistance
Thermocouple typesK, J, T, N and EClass 1 tolerance as standard
Sheath material304 stainless, 316 stainless, Inconel 600Inconel for high temperature
Sheath diameter1.5, 3, 4.5 and 6 mm3 and 6 mm are the stocked sizes
Probe length50 to 500 mmLonger and lagged versions to order
RTD temperature rangeMinus 100 to 400 CClass A or better
Thermocouple rangeUp to 1149 C in Inconel, 899 C in 304Per calibration and sheath
Pressure at the sheath20 bar at 3 mm, 40 bar at 6 mmProbe body rating
Response, T66 in liquid3 s for a Pt100, 4 s for a thermocoupleClosed end sheath
ThreadsM8 x 1, M10 x 1, G1/8, G1/4, G1/2, 1/4 NPTMatch the block port
Lead insulationPVC, silicone, FEP, fibreglassSets the lead temperature limit

Included Models and Order Codes

The thermocouple block is grouped by calibration and sheath: SS for 304 stainless, IN for Inconel 600, XL for the compacted mineral sheath, with the junction letter and the length in inches inside the part number. The RTD rows are the Pt100 assemblies used on analyser blocks, with the element class and the wiring stated. The last row is an ordering code rather than a stocked number, which is how a Pt100 with a specific thread and lead length is specified.

Part NumberTypeSheathDiameterLengthRangeUse
TJ36-CASS-18U-6Type K, ungrounded304 stainless3 mm150 mm899 CGeneral block temperature
TJ36-CASS-116U-6Type K, ungrounded304 stainless1.5 mm150 mm899 CFast response in small ports
TJ36-CAIN-18U-6Type K, ungroundedInconel 6003 mm150 mm1071 CHeaters and hot gas
TJ36-CAIN-18U-12Type K, ungroundedInconel 6003 mm300 mm1071 CDeeper immersion
TJ36-ICSS-18U-6Type J, ungrounded304 stainless3 mm150 mm521 CReducing atmospheres
TJ36-ICIN-116G-12Type J, groundedInconel 6001.5 mm300 mm441 CGrounded tip on metal blocks
TJ36-CAXL-18U-6Type K, ungroundedMineral XL3 mm150 mm1149 CLong life at high temperature
TJ36-NNIN-18U-6Type N, ungroundedInconel 6003 mm150 mm1200 C nominalDrift resistant at temperature
P3A-S316-125-PX-6-PFXX-80-STWLPt100, 3 wire, class A316 stainless3.2 mm150 mm260 CWet sample lines
P-A-6-100-M8-XM-2Pt100 ordering code, class A304 stainless6 mm100 mm400 CThread and lead made to order

Key Features

Element class stated – class A, 1/3 DIN and 1/10 DIN Pt100 options, so the tolerance is known before the loop is tuned

Wiring matched to the input – 2, 3 and 4 wire builds, with 3 wire as the usual compromise for lead resistance

Junction choice on thermocouples – grounded for fast response on metal, ungrounded for isolation, exposed for gas

Sheath by temperature – 304 stainless to 899 C, Inconel 600 to 1071 C, mineral XL to 1149 C

Thread to the port – M8, M10, G1/8, G1/4, G1/2 and 1/4 NPT, with adjustable compression fittings where the depth has to move

Lead insulation by environment – PVC to 100 C, silicone to 200 C, FEP to 250 C, fibreglass to 400 C

Applications

These probes are fitted to a metal body with a port, so the application is usually described by the block rather than by the sensor.

Analyser reaction and sample blocks – a 3 mm Pt100 in a 1/4 NPT port for block temperature, with a type K alongside as an over temperature check

Column ovens and heater blocks – a Pt100 in a G1/4 port, 3 wire to the controller, with the sheath length set by the block depth

Hot gas and exhaust lines – a type K in an Inconel sheath, ungrounded, where a Pt100 would not survive the sheath temperature

Temperature probes and the boards that read them are quoted together, so SUPERB PCB and SUPERB PCBA orders can include the probe and its front end.

Sourcing and Cross-Reference

A probe is a mechanical part as much as a sensor. The sheath length has to reach the middle of the flow, the thread has to match the port without an adaptor, and the lead has to leave the block without touching it. When a probe is quoted from a drawing we ask for three dimensions: port thread, insertion depth and the space available for the lead to bend.

Interchangeability is the second point. A class A Pt100 from one maker and a class B from another will read several tenths of a degree apart at 200 C, which matters when a method names a block temperature. We quote the element class and the calibration basis together so two batches of probes read the same.

Thermocouple ageing is worth a note in the maintenance file. Type K drifts in the first tens of hours at high temperature and then settles, so a probe that reads 3 C high after a week in a 900 C oven is often behaving normally. For long term use above 800 C, type N in an Inconel sheath holds its calibration better and is stocked for that reason.

Probe, gland and connector are kitted through SUPERB Assembly, with the lead length cut to the enclosure drawing.

Q: Can you supply a Pt100 probe with a 1/4 NPT thread, a 100 mm sheath and a 3 wire FEP lead for a sample block?

A: Yes. SUPERB Tech quotes Pt100 and thermocouple probes against the port thread, the insertion depth and the controller input, and states the element class.

Why Choose SUPERB for RTD and Thermocouple Probes

  1. Port dimensions first: thread, insertion depth and lead clearance confirmed before the probe is quoted
  2. Class and calibration stated: element class and tolerance named, so two batches read the same
  3. Sheath by temperature: 304, 316, Inconel and mineral XL options with the working limit given
  4. Lead insulation matched: PVC, silicone, FEP and fibreglass options tied to the temperature at the gland

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Thermocouple and RTD Front Ends, NTC Thermistors and Temperature Probes, Column Ovens and Heater Blocks, Inline Fluid Heaters and Peltier Chillers, Immersion Assemblies and Sample Probes, Calibration Buffers and Conductivity Standards.