Reed Switches and Magnetic Actuators for Position Sensing
Product Specifications
Product Overview
A reed switch is two ferromagnetic blades sealed in a glass tube with a small gap between them. Bring a magnet close and the blades become magnetised, pull together and close the contact. There is no coil, no standby current and no wear from a sliding contact, which is why the part is still used for a door contact, a float level switch and a flow meter rotor where a battery has to last years. The contact is sealed from the environment, so it works under water, in dust and in a washdown enclosure as long as the leads and the potting hold.
Sensitivity is quoted in ampere turns, written AT, and it is the field at which the switch closes. A 12 to 18 AT part closes in a weak field and works at a longer distance from a given magnet; a 32 to 38 AT part needs a stronger field and works closer, which makes it harder to trigger by accident. The AT band is not a distance. It becomes a distance only when a named actuator is used, with a stated pole orientation, so a quote that gives sensitivity without the actuator leaves the mechanical engineer to find the rest by test.
Contact form decides the circuit. Form A is normally open and closes on magnet approach, which is the part used for a counter or a door alarm. Form B is normally closed and opens on approach, which fails safe on a broken wire. Form C is a changeover with three leads, used where a controller needs to see both states. The MDRR-DT changeover part on this page switches 5 W at 175 V, half the rating of the form A parts in the same body size, because the third lead takes space inside the glass.
The load is where a reed switch is most often overrated. A 10 W part means 10 W of resistive load; a lamp, a capacitor or a long cable presents an inrush several times the steady current and welds the blades on the first operation. A relay coil needs a diode across it, and a cable longer than a few metres needs an RC snubber or a series resistor to limit the discharge through the contact. The same rule applies at the other end: a reed switching a microcontroller input carries almost nothing, and the part runs for its full mechanical life.
The body and the mounting decide the assembly. A 15.24 mm glass tube can be bent or cracked by a lead that is clamped too close to the seal, and the sensitivity of a glass switch shifts if the part is dropped, because the blades move inside the tube. SMD versions such as the MK23 and the CT05 remove the bending problem and are placed by the same machine as the rest of the board. Axial glass parts are still used where the switch has to sit inside a float or a cylinder, and there the leads are formed before soldering, not after.
The actuator is half the sensor. An AlNiCo-5 magnet such as the 57020 or the 57045 holds its field at up to 105 C and is the usual match for a reed switch, because its field is stable over temperature and it can be machined into a small cylinder. A neodymium magnet is stronger for its size and suits a long operate distance, but its field falls faster as the temperature rises. Whichever is used, the pair is measured together: the same switch closes at one distance with one magnet and at a different distance with another.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Contact form | Form A normally open, Form C changeover | Per part number |
| Switching power | 5 W, 10 W, 20 W | Per part number |
| Switching voltage | 140 VDC, 170 VDC, 180 VDC, 200 VDC, 140 VAC | Per part number |
| Switching current | 0.25 A, 0.35 A, 0.5 A, 1 A | Per part number |
| Sensitivity | 6 to 10 AT up to 32 to 38 AT | Per part number |
| Contact resistance | 100 mOhm to 160 mOhm maximum | Per part number |
| Insulation resistance | 10 to the 9 Ohm minimum up to 10 to the 12 Ohm | Per part number |
| Operate time | 0.5 to 0.6 ms maximum including bounce | Littelfuse and Standex parts |
| Release time | 0.05 to 0.2 ms maximum | Per part number |
| Body length | 7.00 mm, 12.70 mm, 14.70 mm, 15.24 mm | Glass parts |
| Breakdown voltage | 250 VDC on the 200 VDC parts | MDCG-4, MDSR-7 |
| Operating temperature | -40 to 125 C | Glass parts |
| Actuator material | AlNiCo-5, 11,000 G retentivity, 620 Oe coercivity | 57020, 57045 |
| Actuator temperature | 105 C maximum | 57020, 57045 |
Included Models and Order Codes
The rows below are the switch families we quote most often, in glass and surface mount form, with the sensitivity band named because two parts in the same body can differ by a factor of two in operate field. A dash means the maker does not publish that figure for the part.
| Part Number | Contact Form | Rating | Voltage | Current | Sensitivity | Body |
|---|---|---|---|---|---|---|
| MDCG-4-12-18 | Form A, SPST-NO | 10 W | 200 VDC, 140 VAC | 0.5 A DC, 0.35 A AC | 12 to 18 AT | 15.24 mm glass, 2.28 mm |
| MDCG-4-17-28 | Form A, SPST-NO | 10 W | 200 VDC, 140 VAC | 0.5 A DC, 0.35 A AC | 17 to 28 AT | 15.24 mm glass, 2.28 mm |
| MDCG-4-22-28 | Form A, SPST-NO | 10 W | 200 VDC, 140 VAC | 0.5 A DC, 0.35 A AC | 22 to 28 AT | 15.24 mm glass, 2.28 mm |
| MDCG-4-32-38 | Form A, SPST-NO | 10 W | 200 VDC, 140 VAC | 0.5 A DC, 0.35 A AC | 32 to 38 AT | 15.24 mm glass, 2.28 mm |
| MDSR-7-10-25 | Form A, SPST-NO | 10 W | 200 VDC, 140 VAC | 0.5 A DC, 0.35 A AC | 10 to 25 AT | 12.70 mm glass, 1.80 mm |
| MITI-3V1 | Form A, SPST-NO | 10 W | 170 VDC | 0.25 A | 6 to 10 AT | 7.00 mm glass, 1.80 mm |
| MDRR-DT | Form C, SPDT changeover | 5 W | 175 VDC | 0.25 A | 15 to 30 AT family | 14.70 mm glass |
| MK23-35-D-2 | Form A, SPST-NO | 20 W | 200 V | 1 A | 20 to 25 AT | SMD, 7 to 21 mm glass inside |
| MK23-66-C-2 | Form A, SPST-NO | 10 W | 180 V | 0.5 A | 15 to 20 AT | SMD, gull wing leads |
| CT05-1535-G1 | Form A, SPST-NO | 5 W | 140 VDC | 0.35 A | 15 to 35 AT | Molded SMD, 5 mm |
Magnetic Actuators
A reed switch is quoted with an actuator because the operate distance belongs to the pair. The two AlNiCo-5 parts below cover the usual PCB and cylinder mountings, and both hold their field to 105 C.
| Part Number | Type | Material | Retentivity | Coercivity | Dimensions | Use |
|---|---|---|---|---|---|---|
| 57020-000 | Cylindrical actuator | AlNiCo-5 | 11,000 G | 620 Oe | 5.10 mm dia x 15.24 mm | Cylinder and float mountings, matched to 59021 sensors |
| 57045-000 | Actuator with PCB clips | AlNiCo-5 | 11,000 G | 620 Oe | 17.78 x 3.30 x 4.32 mm | Clips onto a board or a door edge, matched to 59045 sensors |
Key Features
Sensitivity band named – Every row gives the AT band, because a 12 to 18 AT part and a 32 to 38 AT part in the same body close at very different fields.
Zero standby power – The contact closes on the magnet field alone, so a battery powered door or meter node draws nothing while it waits.
Glass and SMD bodies – Axial glass parts for float and cylinder mountings and SMD parts for machine placement are both in the list, at the same contact ratings.
Form A and Form C – Normally open parts for counting and changeover parts for state sensing are listed side by side with their own ratings.
Matched actuators – The AlNiCo-5 actuators are listed with retentivity and dimensions, so the operate distance can be measured on the real pair.
Hermetic contact – The blades sit in a sealed glass tube, so dust, wash water and condensation do not reach the contact surface.
Applications
These parts cover position and level sensing where the contact has to work without power and without maintenance.
Door and window contacts – A 15.24 mm form A part behind a plastic housing closes when the magnet in the frame comes within range, and the sealed contact works through dust and paint.
Float level and flow meters – A 7 mm MITI part at 6 to 10 AT fits inside a small float, and the changeover MDRR-DT gives a controller both the full and the empty state from one sensor.
Utility and gas meters – An SMD MK23 part counts a rotating magnet through a sealed wall, where an optical sensor would fog and a Hall part would need a supply rail.
Reed switches are placed on the SUPERB PCB and in the SUPERB PCBA build before the magnet is fitted to the moving part, so the operate distance is measured on the real assembly rather than on a drawing.
Sourcing and Cross-Reference
Reed switches are ordered by sensitivity band and body length, and the actuator is often left out of the enquiry. That is the gap we close first. A customer who has a working sample can send the magnet with it, and the replacement is quoted with the same AT band so the operate distance stays in the same place. Without the actuator, the band is still quoted, but the distance has to be set again on the assembly.
Obsolete reed parts are common because the glass bodies change and the AT bands do not. Where a body has gone, a part in a shorter or longer tube can usually be fitted, but the operate distance moves with the length, so the mechanical stop or the magnet position has to be checked. We quote the body length and the sensitivity band together so that change is visible before the order.
Where a board is already built, the SMD parts are the practical replacement for a glass part that has been discontinued, because they are placed and reflowed with the rest of the board. The contact ratings are the same order, and the AT band can be picked to keep the existing magnet.
SUPERB Assembly keeps the reed leads clamped during soldering and never drops the parts, because a mechanical shock shifts the sensitivity of a glass switch.
Q: Can you supply a reed switch and the matching actuator as one pair, with the operate distance stated?
A: Sensitivity, load and body length decide it; the SUPERB Tech desk quotes the switch and the actuator together so the operate distance comes from one matched pair.
Why Buy Reed Switches Through SUPERB
- Pair quoted together: Switch and actuator are quoted as a matched pair, so the operate distance is a known figure rather than a test result.
- AT band stated: Sensitivity is named per part, which is what the mechanical tolerance is calculated from.
- Load checked: The load type is confirmed before a rating is quoted, because a lamp or a long cable derates the contact well below its resistive figure.
- Glass and SMD: Both body styles are available, so a discontinued glass part can be replaced on a board that is already in production.
- Handling in the build: Leads are clamped during soldering and parts are not dropped, which keeps the sensitivity band the maker shipped.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Hall Effect Switches and Latches, Magnetometer and Compass Sensors, Inductive Proximity and Photoelectric Sensors, Current Transformers for Energy Metering, Obsolete Part Replacement.