Foot Switches for Machine Control
Product Specifications
Product Overview
A foot switch is bought for one reason: the operator needs both hands on the work. On a press, a bending machine or a cable stripping bench the pedal frees the hands for positioning, and the machine only runs while the pedal is held. The same part is also used as a jog control at commissioning, where an engineer needs short pulses while watching a shaft turn.
The electrical detail that matters is the contact arrangement, not the pedal colour. Almost every industrial type carries one normally closed and one normally open contact block, and the NC side has positive opening: the contact is forced apart by the pedal return spring through a rigid link, not by a spring inside the block. That is the property a safety circuit relies on when the pedal is released.
Three things decide the order. First, one step or two step: a two step pedal gives a slow then fast action on the same travel, which is how a machine distinguishes positioning from working stroke. Second, momentary or latching: a latching pedal stays down until pressed again, which suits a long run rather than a guarded move. Third, housing and sealing: a plastic body at IP66 is normal on a clean bench, while a die-cast aluminium body with a shield is chosen where swarf or a dropped workpiece lands on the pedal.
Key Specifications
| Family | Housing | Contact arrangement | Rated current | Sealing | Note |
|---|---|---|---|---|---|
| Schneider XPEB110 | plastic, blue, no cover | 1 NC + 1 NO, one step | 3 A at 240 V AC-15 | IP66 | positive opening, 10 million cycles |
| Schneider XPEB111 | plastic, blue, no cover | 2 NC + 1 NO, one step | 3 A at 240 V AC-15 | IP66 | same body, extra NC for a second circuit |
| Schneider XPEB211 | plastic, blue, no cover | 2 NC + 1 NO, two step | 3 A at 240 V AC-15 | IP66 | first step signal, second step working |
| Schneider XPEA110 | plastic, black, no cover | 1 NC + 1 NO, one step | 3 A at 240 V AC-15 | IP43 | light duty, bench equipment |
| steute GF 1OE/1S RE | die-cast aluminium, latching | 1 NC + 1 NO, latching | 16 A at 400 V AC-15 | IP65 | stays engaged, 16 A gG fuse |
| steute GFSM 1OE/1S | die-cast aluminium, shield | 1 NC + 1 NO, one step | 6 A at 400 V AC-15 | IP65 | protective shield, 1.258 kg |
| steute GF ZS 2S D | die-cast aluminium, enable | 3 position enable, 2 NC | 3 A at 400 V AC-15 | IP65 | EN 60947-5-8 enable function |
| steute Ex GF 1OE/1S | die-cast aluminium, Ex | 1 NC + 1 NO, slow action | 6 A at 250 V AC-15 | IP65 | zone 1 and 21, 3 m cable |
Included Models and Order Codes
The codes below are the ones quoted most often. On Schneider the letter after XPE is the housing colour and the three digits set the contact count and step: 110 is one step with one NC plus one NO, 111 adds an NC block, 211 is the two step version of the same body. On steute the article number is the order key, and the suffix RE marks the latching version, which is a different mechanism rather than the same pedal with a different label.
| Part number | Family | Steps | Contacts | Current | Sealing | Weight |
|---|---|---|---|---|---|---|
| XPEB110 | Schneider XPE | one step | 1 NC + 1 NO | 3 A, 240 V AC-15 | IP66 | 0.57 kg |
| XPEB111 | Schneider XPE | one step | 2 NC + 1 NO | 3 A, 240 V AC-15 | IP66 | 0.57 kg |
| XPEY110 | Schneider XPE | one step | 1 NC + 1 NO | 3 A, 240 V AC-15 | IP66 | 0.57 kg |
| XPEG110 | Schneider XPE | one step | 1 NC + 1 NO | 3 A, 240 V AC-15 | IP66 | 0.57 kg |
| XPEB211 | Schneider XPE | two step | 2 NC + 1 NO | 3 A, 240 V AC-15 | IP66 | 0.57 kg |
| XPEA110 | Schneider XPE | one step | 1 NC + 1 NO | 3 A, 240 V AC-15 | IP43 | 0.275 kg |
| 1048462 (GF 1OE/1S RE) | steute GF | latching | 1 NC + 1 NO | 16 A, 400 V AC-15 | IP65 | 0.68 kg |
| 1048638 (GFSM 1OE/1S) | steute GFSM | one step | 1 NC + 1 NO | 6 A, 400 V AC-15 | IP65 | 1.258 kg |
| 1048461 (Ex GF 1OE/1S 3m) | steute Ex GF | one step | 1 NC + 1 NO | 6 A, 250 V AC-15 | IP65 | on request |
| 1317316 (Ex GF 1NC/1NO 5m) | steute Ex GF | one step | 1 NC + 1 NO | 6 A, 250 V AC-15 | IP65 | on request |
| 1394278 (GF IK 2S D 2OE1OES-ZS) | steute GF ZS | enable, 3 position | 2 NC + 1 NO | 3 A, 400 V AC-15 | IP65 | on request |
Reading the Contact Data Before You Order
The current on the label is a thermal figure, and the load it switches is usually a coil. The table below converts the common pedal ratings into the current the same contact will carry in the categories that matter on a machine, so a 3 A type is not mistaken for a 3 A motor starter.
| Rating on the label | AC-15 at 240 V | DC-13 at 24 V | Typical load | Note |
|---|---|---|---|---|
| 3 A, 240 V (XPEB) | 3 A | 10 W resistive, 0.27 A at 250 V DC | contactor coil, PLC input | A300 and Q300 utilisation |
| 6 A, 400 V (GFSM) | 6 A | not listed for this type | relay coil, small contactor | 6 A gG fuse for protection |
| 16 A, 400 V (GF RE) | 16 A | not listed for this type | direct switching of a small motor | 16 A gG or gN fuse |
| 3 A, 400 V (GF ZS) | 3 A | not listed for this type | safety relay input | 4 A gG fuse, 1100 A conditional |
Key Features
Positive opening on the NC contact – the return spring drives the contact apart through a rigid link, which is what a guard monitoring circuit needs to see when the pedal is released, to EN IEC 60947-5-1 appendix K.
One step and two step in one housing – a two step pedal sends a positioning signal on the first travel and the working command on the second, with the same mounting footprint as the single step version.
IP66 on the plastic XPE body – washdown and coolant splash are the normal conditions at a machine base, and the sealing is achieved by the cover and the gland entries rather than by a boot over the pedal.
10 million mechanical cycles – the XPE return spring is stainless steel and the pedal pivots on a plain bearing, so the wear item is the contact block and not the housing.
Latching version for long runs – the steute GF RE holds the contact closed after release, which is what a chip conveyor or a pump on a manual station needs, and it is a different mechanism from the momentary type.
Ex versions for zone 1 and 21 – the Ex GF family carries the same pedal geometry with a flameproof housing and a pre-wired cable, for mixers and coating stations inside a hazardous area.
Applications
The pedal is chosen from how the machine is held, not from the current alone. These three uses cover most of the orders we see.
Press, punch and bending stations – one NC in the safety circuit and one NO as the cycle command, with a shield where a workpiece can fall onto the pedal.
Bench and assembly stations – IP66 plastic body at the operator's feet for a screwdriver or a crimp tool, with the two step version used to run a slow approach before the full stroke.
Commissioning and service jog – a latching pedal lets one engineer run a conveyor while both hands are inside the guard, and release it with a second press rather than by holding the pedal down.
The pedal is quoted with the panel that reads it, so the SUPERB PCBA and the SUPERB PCB are checked against the same machine list and the input common agrees with the pedal return.
Sourcing and Cross-Reference
Match the pedal to the circuit before the brand. If the NC contact feeds a safety relay, the positive opening property and the B10d figure are the selection data, and a cheap pedal without positive opening cannot be used there even if it looks identical. If the pedal only commands a PLC input, a 3 A plastic body is enough and the metal housing is weight without benefit.
Check the cable entry against the installation. The XPE body takes two M20 plain holes, so a gland has to be ordered with the switch, and a pre-wired steute type arrives with a fixed cable length that decides where the junction box goes. On a moving machine base the cable is the part that fails first, so a pre-wired type with a longer lead is often the cheaper answer than a gland and a field termination.
Watch the contact count when a second function is added. A pedal with one NC plus one NO covers run and stop, but a machine that also needs a status signal to the PLC needs the 2 NC plus 1 NO body, and that is a different order code rather than an extra block in most families. See lead time and availability when the original type is on allocation, and shortage recovery when a machine build is waiting on the pedal alone.
The SUPERB Assembly team keeps the NC pair on separate terminals all the way to the safety relay, because a shared return hides the second channel the relay is checking.
Q: Can you supply the pedal together with the gland, the safety relay and the contactor it drives, on one matched list?
A: Yes. Send the machine function, the number of contacts and whether the NC side feeds a safety circuit, and the SUPERB Tech team returns the family, the step count and the housing that fit.
Why Machine Builders Buy Foot Switches From SUPERB
- Contacts stated per code: every row says how many NC and NO blocks the pedal carries, so a second circuit does not turn into a second order.
- Positive opening flagged: the NC property is written against the family, because that is the line between a command pedal and a safety input.
- Housing and shield together: plastic, metal and shielded bodies are quoted in the same list, which keeps a spare that fits the existing mounting holes.
- Sealing and cable entry in the open: IP rating and gland size are listed, so the enclosure work is planned before the switch arrives.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Industrial Pushbuttons and Selector Switches for Panel Fronts, Safety Relay Modules for Guard Monitoring, Mechanical Limit Switches for Position Sensing, Door Interlock Switches for Safety Circuits, Contactors and Reversing Contactors for Motor Loads.