Mechanical Limit Switches for Position Sensing
Product Specifications
Product Overview
A mechanical limit switch is the simplest position sensor in a machine. A lever, a plunger or a rod touches the moving part, the actuator moves a few millimetres, and a contact block changes state. There is no supply, no adjustment of a sensing distance and no reflector to clean. The output is a dry contact that a PLC input, a contactor coil or a safety relay can read directly.
The two mechanisms inside are not interchangeable. A snap action contact closes and opens at a fixed point with a spring, so the contact moves fast even when the actuator moves slowly, which keeps the arc short and the repeat accuracy good. A slow action contact follows the actuator all the way, so the contact travel matches the lever travel and the contact wipes as it closes, which is better on low current signals and on a slowly approaching guard door.
The third distinction is the safety function. A guard circuit needs a normally closed contact that opens by direct mechanical linkage when the actuator is pushed, so a welded contact or a broken spring cannot hold the machine enabled. That mechanism is stated on the datasheet as direct opening or positive opening, and it is the reason a safety limit switch costs more than a general purpose switch with the same body.
Key Specifications
| Family | Contact arrangements | Actuators | Thermal current | Enclosure | Cable entry | Note |
|---|---|---|---|---|---|---|
| Omron D4N | 1NC/1NO or 2NC, snap or slow; 3 contact versions | roller lever, plunger, rod, fork lever | 10 A | IP67 | Pg13.5, G1/2, M20, M12 | direct opening on NC |
| Omron D4MC | SPDT | hinge lever, roller lever, plunger | 10 A at 250 V AC | IP67 | screw terminals | general purpose, 10 million operations |
| Schneider XCKP | 1NC plus 1NO | plunger, roller lever, variable length lever | 10 A thermal, AC-15 3 A at 240 V | IP66 and IP67 | M16 or Pg11 | 31 x 65 x 30 mm, positive opening |
| Honeywell SZL-VL-S | SPDT, snap action | pin plunger, roller plunger, side rotary | 10 A at 250 V AC | IP67 | conduit entry or cable gland | die cast metal housing |
Included Models and Order Codes
The rows below are the codes we quote most often. In the Omron D4N code the first digit after the dash is the conduit type, 1 for Pg13.5, 2 for G1/2 and 4 for M20, and the last two digits are the actuator and mechanism, so D4N-1122 and D4N-4122 are the same switch with a different gland thread. On Schneider XCKP the digits after XCKP set the head and the contact operation, and the suffix P16 or G11 is the cable entry.
| Part number | Family | Contacts | Actuator | Cable entry | Note |
|---|---|---|---|---|---|
| D4N-1120 | D4N | 1NC/1NO snap | roller lever, resin lever and roller | Pg13.5 | direct opening |
| D4N-1122 | D4N | 1NC/1NO snap | roller lever, metal lever, resin roller | Pg13.5 | direct opening |
| D4N-2122 | D4N | 1NC/1NO snap | roller lever, metal lever, resin roller | G1/2 | same body, G1/2 thread |
| D4N-4122 | D4N | 1NC/1NO snap | roller lever, metal lever, resin roller | M20 | same body, M20 thread |
| D4N-1222 | D4N | 2NC snap | roller lever, metal lever, resin roller | Pg13.5 | two NC for a guard circuit |
| D4N-1A22 | D4N | 1NC/1NO slow | roller lever, metal lever, resin roller | Pg13.5 | slow action for low speed approach |
| D4N-1C20 | D4N | 2NC/1NO slow | roller lever, resin lever and roller | Pg13.5 | three contacts in one body |
| D4MC-2020 | D4MC | SPDT | short hinge roller lever, side mount | screw terminals | general purpose |
| D4MC-5000 | D4MC | SPDT | panel mount plunger | screw terminals | same operating point as a Z basic switch |
| XCKP2121P16 | XCKP | 1NC plus 1NO snap | thermoplastic roller lever plunger, one direction | M16 | positive opening, 36 N |
| XCKP2621P16 | XCKP | 1NC plus 1NO slow | roller lever plunger, make before break | M16 | slow break for a PLC signal |
| XCKP2102P16 | XCKP | 1NC plus 1NO snap | steel roller plunger, two directions | M16 | 30 degree cam actuation |
| XCKP2145G11 | XCKP | 1NC plus 1NO snap | variable length roller lever, two directions | Pg11 | adjustable reach |
| SZL-VL-S-D-N-M | SZL-VL-S | SPDT snap | top pin plunger | conduit entry | metal housing, IP67 |
| SZL-VL-S-H-N-M | SZL-VL-S | SPDT snap | top roller plunger, 12.5 mm steel roller | conduit entry | 9 N operating force |
Matching the Actuator to the Motion
The actuator is chosen from the way the machine approaches the switch, not from the space left on the bracket. The table pairs the usual motions with an actuator and states what has to be checked on the drawing. Travel figures are the ones the makers publish for the standard head.
| Motion at the switch | Actuator | What to check | Typical use |
|---|---|---|---|
| straight approach, short stroke | top pin or roller plunger | pre-travel and over-travel against the stop position | end stop on a slide or a press ram |
| approach from the side, rotating arm | roller lever, fixed or adjustable length | lever radius and the angle that trips the contact | conveyor diverter, hinged guard |
| two possible directions | cross roller plunger | which direction trips first and the return spring force | pallet stop, bidirectional carriage |
| slow closing door | slow action lever with direct opening | positive opening travel and force on the NC contact | guard door on a machine cell |
| long travel, soft contact | steel wire or coil spring rod | rod length and the minimum force at the tip | fabric or film web edge sensing |
Key Features
Dry contact output – no supply and no sensing distance, so the switch can drop into a circuit that already has a PLC input or a relay coil waiting for it.
Direct opening on the NC contact – a safety rated version opens by mechanical linkage even if the contact welds, which is the property a guard monitoring circuit relies on.
Snap or slow action in one family – the same body is ordered with either mechanism, so a fast cam and a slow guard door can use the same bracket and the same spare.
Three gland threads – Pg13.5, G1/2 and M20 on the same body means the switch matches the cable gland already stocked in the panel shop.
IP66 and IP67 sealing – washdown and coolant mist are the normal environment on a machine frame, and the seal is stated rather than assumed.
10 million mechanical operations – the mechanism outlasts the machine cycle count in most handling equipment, so the switch is replaced with the machine, not between services.
Applications
Three positions where a mechanical switch still beats a proximity sensor. Each one sets the actuator and the contact arrangement.
End stop on a linear slide – roller plunger on the moving carriage, one NC contact into the drive enable and one NO contact into the PLC, so the stop is hard wired and the position is reported.
Hinged guard door – slow action lever with direct opening on the NC contact, wired into a safety relay as one channel of a dual channel circuit, with the second switch on the frame.
Cam position on a rotating shaft – roller lever on a cam disc, snap action so the contact changes state at the same angle every revolution regardless of shaft speed.
The position switch is quoted with the controller that reads it, so the SUPERB PCBA and the SUPERB PCB are checked against the same machine list and the input type matches the contact.
Sourcing and Cross-Reference
Choose the mechanism from the approach speed. A cam that passes the lever in a few milliseconds needs snap action, because a slow action contact would still be travelling when the cam has gone. A guard door that closes by hand needs slow action, because the contact has to follow the door and open positively before the door is fully closed.
Check the electrical load against the contact rating, not against the thermal current. The 10 A figure on most bodies is a thermal current, while the switching rating in a DC circuit is far lower, often 0.27 A at 250 V DC in the AC-15 and DC-13 categories. A switch that carries a 10 A rating can still weld on a 24 V DC brake coil without an arc suppressor.
Keep the safety and the standard circuits apart. A general purpose switch on a guard door is a switch without direct opening, and no amount of wiring turns it into a safety device. If the circuit is a guard monitoring function, the NC contact has to be stated as direct opening and the switch has to be the safety version of the family. See lead time and availability for the build schedule and shortage recovery when the original switch is on allocation.
The SUPERB Assembly team keeps the safety channel on its own two cores back to the relay, because a shared return turns a dual channel guard circuit into a single channel one.
Q: Can you supply the limit switch with the lever or plunger already fitted, so the bracket does not need a second actuator order?
A: Yes. Send the approach direction, the travel available, the contact arrangement and whether the circuit is a guard function, and the SUPERB Tech team returns the family, the actuator and the cable entry that fit.
Why Machine Builders Buy Limit Switches From SUPERB
- Mechanism stated per code: snap action, slow action and direct opening are separated in the table, so a guard circuit never receives a general purpose switch by mistake.
- Actuator and thread together: the lever type and the gland thread are on the same row, which is the pair that has to match the bracket and the cable gland.
- Contact rating in the open: the switching category is quoted next to the thermal current, so a DC coil load is checked before the switch is fitted.
- Spares for installed machines: the same body with Pg13.5, G1/2 and M20 entries is quoted together, which keeps a service part that fits the existing cable gland.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Door Interlock Switches for Safety Circuits, Safety Relay Modules for Guard Monitoring, Inductive Proximity and Photoelectric Sensors for Automation, Reed Switches and Magnetic Actuators for Position Sensing, Industrial Pushbuttons and Selector Switches for Panel Fronts.