Contact Us

Door Interlock Switches for Safety Circuits

Tongue operated safety switches with 1NC/1NO, 2NC, 2NC/1NO and 3NC contact forms. Slow action contacts with positive opening on the NC side, 10 A thermal current. IP67 bodies in glass fibre reinforced thermoplastic, with M20, M12 or PG13.5 entry. Actuator ordered separately so the approach direction matches the door.
quote now

Product Specifications

Product Overview

A door interlock switch is the part that tells the control system a guard is closed. It is not a limit switch with a different label: the NC contact has to open by positive mechanical action when the actuator withdraws, so a welded contact cannot leave the machine running with the door open.

Two families cover most cabinet and guard doors. The tongue operated switch has a separate actuator that is mounted on the door and enters the head of the switch; the head can be rotated so the same switch works on a left or a right hinged door. Contact forms run from 1NC/1NO for a simple guard to 3NC for a door that feeds two contactors and a monitoring relay.

The installation detail that decides whether it works is the actuator gap. Too far and the guard is reported closed before the door is shut; too close and the tongue hits the head on a slammed door. The switch body, the actuator and the door stop have to be set together, which is why the actuator is a separate line on the order and not an accessory in the box.

Key Specifications

PropertySchmersal AZ 17Omron D4NS
Contact forms1 NO and 1 NC, or 2 NC1NC/1NO, 2NC, 2NC/1NO, 3NC, and make before break versions
Thermal current10 A10 A conventional free air
Utilisation categoryAC-15 230 V 4 A, DC-13 24 V 4 AAC-15 240 V 3 A, DC-13 250 V 0.27 A
Positive opening11 mm travel, 17 N minimum per NC contact10 mm travel, 60 N minimum opening force
ProtectionIP67IP67
Housingglass fibre reinforced thermoplastic, 30 x 60 x 30 mmresin body, slow action head
ConnectionM16 cable entry or M12 4-pin connectorPG13.5, G1/2, M20, 1/2-14NPT or M12 connector
Mechanical life1,000,000 operations minimum1,000,000 operations minimum

Included Models and Order Codes

The code after the family name is the contact form and the entry, not the actuator. AZ 17-11ZRK is one NO plus one NC with a latching force of 30 N and an M16 entry; the ST suffix swaps the cable entry for an M12 connector. Omron uses the digit after D4NS for the entry: 1 is PG13.5, 4 is M20, 9 is M12.

Part numberContact formEntry or connectorBodyProtection
AZ 17-11ZRK1 NO, 1 NCM16 cable entry30 x 60 x 30 mmIP67
AZ 17-11ZRK-ST1 NO, 1 NCM12, 4-pin, A-coded30 x 78.5 x 30 mmIP67
AZ 17-11ZRK-16371 NO, 1 NC, gold contactsM16 cable entry30 x 60 x 30 mmIP67
D4NS-1AF1NC/1NO, slow actionPG13.5resinIP67
D4NS-1BF2NC, slow actionPG13.5resinIP67
D4NS-1CF2NC/1NO, slow actionPG13.5resinIP67
D4NS-1DF3NC, slow actionPG13.5resinIP67
D4NS-4CF2NC/1NO, slow actionM20resinIP67
D4NS-9BF2NC, slow actionM12 connectorresinIP67

Choosing the Contact Form

The contact form follows the safety circuit, not the door. The table is the short version of the usual combinations.

CircuitContact formTypical part
One contactor, one monitoring channel1NC/1NOAZ 17-11ZRK, D4NS-1AF
Two contactors in series2NCD4NS-1BF
Two contactors plus a signal to the PLC2NC/1NOD4NS-1CF, D4NS-4CF
Two doors on one guard, both monitored3NCD4NS-1DF
Machine built for Europe, M20 entry2NC/1NOD4NS-4CF
Machine built for North America, M122NC, quick changeD4NS-9BF

Key Features

Positive opening on the NC contact – the NC side opens by mechanical action, not by spring force alone, which is the property the safety circuit relies on.

Contact forms from 1NC/1NO to 3NC – one family covers a simple guard and a door that feeds two contactors and a monitoring relay.

Rotatable head – the same switch works on a left or a right hinged door, so a spare part fits either side of the machine.

IP67 body – wash-down and coolant mist do not reach the contacts, and the slot cover keeps dust out of the unused opening.

M12 connector option – a door that has to be removed for transport can be unplugged and refitted without re-terminating the cable.

Low level coded actuator – the actuator is coded to the switch, so a screwdriver or a second actuator does not defeat the guard.

Applications

Interlocks are chosen by what the door protects and how often it is opened. Three patterns.

Machine guards and access doors – a tongue switch on the guard, with the actuator on the door and the head set so the NC contact opens before the door is wide enough to reach the tool.

Control cabinets with live busbars – an interlock on the cabinet door that drops the incomer when the door is opened, with a 2NC form feeding two contactors.

Test and burn-in chambers – a switch with an M12 connector, so the door can be lifted off for a chamber service and plugged back without a rewire.

Door stays and interlock switches are ordered with the hinges and locks for the same door, and both the SUPERB PCBA and the SUPERB PCB are checked against the panel wiring schedule so the safety circuit and the door hardware arrive together.

Sourcing and Cross-Reference

Order the actuator with the switch. The switch is supplied without it, and the actuator code depends on the approach direction and the door radius. A switch that arrives without an actuator cannot be commissioned.

Match the entry to the machine market. A machine for Europe normally takes M20; a machine for North America takes 1/2-14NPT; a machine with a pluggable door takes M12. An adapter is available but it adds a joint that can work loose.

Set the gap against the door stop. The actuator has to be inside the operating range when the door is closed and outside it when the door is open by the distance the risk assessment allows. The door stop, not the switch, sets that distance.

Do not rely on the switch to hold the door. The interlock reports position; the hinge and the door stay take the load. A switch used as a door stop fails at the head. See obsolete part cross reference when a machine is rebuilt around a discontinued switch.

The SUPERB Assembly team sets the actuator gap on the bench before the door is hung, because a tongue switch that is set after painting usually ends up too far from the actuator and trips on a slammed door.

Q: Is the actuator included, and can the switch be supplied with an M12 connector for a removable door?

A: Yes. Send the door drawing with the hinge side, the opening angle and the control voltage; the SUPERB Tech team quotes the stay and the interlock with the actuator and the connector that match the door.

Why Builders Buy Interlock Switches From SUPERB

  1. Contact form quoted against the circuit: the NC and NO count is checked against the contactors and the monitoring relay before the part number is confirmed.
  2. Actuator and entry in the same quote: the approach direction, the entry thread and the connector are listed so the switch can be commissioned on arrival.
  3. IP67 and coded actuation: the body is sealed for wash-down and the actuator is coded, so a spare key does not defeat the guard.
  4. Replacement for older machines: the same family covers PG13.5 and M20 entries, so a rebuild does not need the door plate to be re-punched.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Reed Switches and Magnetic Actuators, Inductive Proximity and Photoelectric Sensors, Cam Locks and Key Locking Latches, Continuous and Butt Hinges.