Contact Us
  • Home
  • COMPONENTS
  • PIR Motion Sensors and Pyroelectric Detector Modules

PIR Motion Sensors and Pyroelectric Detector Modules

A PIR sensor detects a change in infrared radiation, not motion itself, so a warm body crossing the field produces a pulse while a steady heat source does not. Module level parts such as the HC-SR501 include the comparator, the relay driver and the adjustable delay, so the output is already a logic level. Bare detectors such as the LHI878 need a lens and a signal chain, and they are chosen when the product has its own optics and firmware. Quiescent current runs from about 50 uA on the module to 170 uA on the digital PaPIRs part, which decides whether a battery product can use it. Every row lists supply, current, angle, range and output, because those decide the lens and the power budget.
quote now

Product Specifications

Product Overview

A passive infrared sensor measures the difference between the infrared radiation arriving from different parts of its field of view. Each element of the pyroelectric ceramic produces a charge when its temperature changes, and a moving warm body changes the radiation on one element faster than on the other, so the differential pair produces a pulse. That is why a PIR sensor detects a person walking across the field and does not detect a radiator standing still in it.

The lens does most of the work. A bare detector with a flat window has a field of view of about 70 to 100 degrees and no idea where in that field the change happened. A Fresnel lens in front of it splits the field into zones, and the sensor sees a sequence of alternating positive and negative pulses as a body crosses zone boundaries, which is what the comparator and the firmware count. That zoning is why the same detector is sold with a 5 m lens and with a 12 m lens, and why the detection range in a data sheet is always quoted with a lens and a temperature difference.

Module level parts put the whole chain on one board. The HC-SR501 carries a dual element detector, a BISS0001 signal processor, a comparator, a delay adjustment from 0.3 seconds to 5 minutes, a trigger mode jumper and a 3.3 V logic output, and it runs from 4.5 V to 20 V with a quiescent current under 50 microamps. That is enough for a lamp or an alarm input, and the adjustable delay removes the need for a timer in the host. The AM312 is the same idea in a 10 x 8 mm board with a fixed 2 second delay and a supply from 2.7 V to 12 V, which suits a battery node that only needs a trigger.

Digital detector parts put the signal chain inside the sensor can. The Panasonic PaPIRs EKMC1601111 integrates the detector, the amplifier, the comparator and the digital output in a TO-5 housing, and specifies 170 microamps average at 5 V with a 5 m detection range at a 4 degree temperature difference, 94 degrees horizontal and 82 degrees vertical coverage in 64 zones. It needs a 30 second stabilisation time after power is applied, during which the output is undefined, which the firmware has to respect.

Bare detectors are chosen when the optics and the signal chain are part of the product. The LHI878 is a dual element part in a TO-5 can with 2 x 1 mm elements and a 95 degree field of view, running from 2 V to 12 V with an internal source follower, and the RE200B is a three pin part with a 69 degree field of view that runs from 3 V to 10 V. Both need a load resistor, a band pass amplifier around 0.1 Hz to 10 Hz and a comparator, and both let the product choose the lens and the threshold.

The tables below list the modules and detectors we quote most often for lighting, intrusion, occupancy and appliance wake up. Supply, current, angle, range and output come from the maker data sheet for each order code.

Key Specifications

ParameterHC-SR501 moduleAM312 moduleEKMC1601111IRA-S210ST01LHI878
TypeModule with lens and signal processorModule with lens and signal processorDigital detector in TO-5 canBare detector in metal can with lensBare dual element detector in TO-5
Supply voltage4.5 V to 20 V2.7 V to 12 V3.0 V to 6.0 V2 V to 15 V2 V to 12 V
Quiescent currentUnder 50 uAUnder 0.1 mA170 uA average, 300 uA maximumSet by the external load resistorSet by the external load resistor
Detection angleUp to 120 degreesUp to 100 degrees94 degrees horizontal, 82 degrees verticalWide pattern lens95 degrees
Detection rangeUp to 7 m3 m to 5 m5 m at 4 C difference, 7 m at 8 C differenceSet by the lens and the signal chainSet by the lens and the signal chain
Output3.3 V logic, high on detection3.3 V logic, high on detectionDigital, active highAnalog voltage from the source followerAnalog voltage from the source follower
Delay and trigger0.3 s to 5 minutes adjustable, repeat or single trigger2 seconds fixed, repeatableInternal timing, 30 s stabilisation at power upSet by the host firmwareSet by the host firmware
Footprint32 x 24 mm board, 23 mm lens10 x 8 mm boardTO-5 canMetal can with lensTO-5 can, 2 x 1 mm elements

Included Models and Order Codes

The order codes below are the ones we quote most often. The three PaPIRs codes differ only in lens colour, which matters for a product where the sensor is visible. Module parts include the lens and the comparator, bare detectors do not, and the quotation states which is which because the firmware work differs by a factor of ten. Where a figure is not published for that exact code the cell is left empty rather than copied from a sister part.

Part NumberTypeSupplyQuiescent currentAngleOutputNote
HC-SR501Module4.5 V to 20 VUnder 50 uAUp to 120 degrees3.3 V logicAdjustable delay and trigger mode, 32 x 24 mm
AM312Module2.7 V to 12 VUnder 0.1 mAUp to 100 degrees3.3 V logicFixed 2 s delay, 10 x 8 mm board
EKMC1601111Digital detector3.0 V to 6.0 V170 uA average94 by 82 degreesDigitalWhite lens, 5 m at 4 C difference
EKMC1601112Digital detector3.0 V to 6.0 V170 uA average94 by 82 degreesDigitalBlack lens, same die as the white version
EKMC1601113Digital detector3.0 V to 6.0 V170 uA average94 by 82 degreesDigitalPearl white lens
IRA-S210ST01Bare detector2 V to 15 VSet by load resistorWide pattern lensAnalogMetal can, lensed, three lead
LHI878Bare detector2 V to 12 VSet by load resistor95 degreesAnalogDual element 2 x 1 mm, TO-5
RE200BBare detector3 V to 10 VSet by load resistor69 degreesAnalogThree pin, differential pair

Key Features

Detection range quoted with the temperature difference – the 5 m figure belongs to a 4 C difference between the body and the background, and the same part reaches 7 m at 8 C, so a range quoted alone is not usable.

Module parts give a logic output – the HC-SR501 and AM312 include the comparator and the driver, so a lamp or an alarm input can be switched without a signal chain on the carrier board.

Adjustable delay where the product needs it – the HC-SR501 delay runs from 0.3 seconds to 5 minutes and can repeat or latch, which removes a timer from the firmware.

Digital detector with a fixed specification – the PaPIRs part specifies current, angle, range and output in one data sheet, which shortens the technical review for a product that must be repeatable.

Bare detectors for custom optics – the LHI878 and RE200B let the product choose the lens and the threshold, which is the route for a wide coverage or a long range requirement.

Low quiescent current for battery nodes – the AM312 draws under 0.1 mA and the HC-SR501 under 50 uA, which is low enough for a node that wakes on motion and reports over a radio.

Stabilisation time stated – the PaPIRs part needs 30 seconds after power up before the output is valid, and ignoring that shows up as a false trigger on every power cycle.

Applications

These parts are quoted for products that react to a person moving, typically where:

Lighting and HVAC control – a corridor or a room light switches on when someone enters, and the adjustable delay on the module keeps it on while the person is still moving.

Intrusion and alarm panels – a detector with a defined angle and range gives a coverage pattern the installer can draw, and the digital output feeds the panel zone input.

Battery nodes and appliance wake up – a node that sleeps until someone walks past needs a quiescent current low enough to survive on a cell, and the AM312 fits that budget.

The detector shares the board with the lens holder, the radio and the power stage, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that board.

Sourcing and Cross-Reference

Selection starts with the coverage the product needs and the temperature conditions on site. A detector rated 5 m at a 4 degree difference will cover less in a warm room where people wear heavy clothing, so the range figure is derated, and a lens with more zones gives a more reliable trigger at the same distance. The second check is the output: a module with a logic output removes the analog chain, while a bare detector needs a load resistor, a band pass amplifier and a comparator, which is worth it only when the product owns the optics.

The third check is power and timing. A mains powered lamp can use the HC-SR501 at 50 microamps and its adjustable delay; a battery node needs the AM312 at under 0.1 mA or a digital detector that sleeps. The stabilisation time after power up has to be respected in firmware, and a product that power cycles the sensor on every wake will trigger falsely unless that time is allowed for. The lens material matters too: high density polyethylene passes the 8 to 14 micron band that the detector needs, and a painted or tinted window can block it.

Where a detector is discontinued, the swap is checked on field of view, element size, supply, output and lens interface at once, because a part with a different element size needs a different amplifier gain. The route for obsolete and last time buy parts is on our source obsolete components page, and the sensitivity comparison is on pin to pin cross reference. Related families are listed under sensors and detectors and multi function ICs.

For volume builds, SUPERB Assembly support covers the detector footprint, the lens holder clearance and the supply filtering that keeps the comparator from triggering on rail noise.

Q: Can you quote AM312 and EKMC1601111, and confirm the detection range at a 4 C temperature difference for both?

A: Yes. Send the coverage, the supply rail and the temperature range on site, and the SUPERB Tech team will confirm the module or detector, the range at the working temperature difference and the quiescent current from the maker data sheet before quoting.

Why Buyers Source PIR Sensors Through SUPERB

  1. Range quoted with its condition: the detection distance is given with the temperature difference and the lens, because a bare distance figure cannot be compared between parts.
  2. Module and bare detector kept apart: the quote states whether the lens, the comparator and the delay are included, so the firmware and the board work are not underestimated.
  3. Quiescent current given for the sleep budget: the 50 uA and 0.1 mA figures decide whether a battery node can keep the sensor powered between reports.
  4. Stabilisation time stated: the 30 second window after power up is quoted with the part, because a false trigger on every power cycle is a field complaint rather than a build fault.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: ambient light and proximity sensors, ultrasonic transducers and distance sensors, phototransistors for optical sensing, gas sensors for air quality.