Needle and Metering Valves for Analyser Lines

Needle, metering and splitter valves for analyser and LC MS lines. Adjustable flow down to 3.5 uL per minute from a 1 mL per minute inlet. PEEK and PTFE wetted path rated to 800 psi, graduated splitter to 4000 psi. 1/4-28 flat bottom and 10-32 coned ports for 1/16 and 1/8 inch tubing.
quote now

Product Specifications

Product Overview

Somewhere on almost every analyser line there is a restriction that has to be adjustable: a split to a mass spectrometer, a back pressure set so a degasser works, or a bleed that keeps a peristaltic pump from pulsing into the cell. A fixed orifice cannot do that job, and a ball valve has too little resolution. That is where a needle or metering valve belongs, and the two numbers that decide the part are the port thread and the tubing outside diameter.

The valves below are PEEK bodies with PTFE seals and a 0.020 inch thru hole, rated to 800 psi for the standard metering and splitter bodies. The graduated splitter raises that to 4000 psi and adds a scale so a working split setting can be written down and returned to, which matters on a method that has already been validated. Shut off valves are listed alongside because they are usually specified with the same port in the same block.

Port style is the most common ordering error. A 1/4-28 flat bottom port and a 10-32 coned port will not interchange, and a valve body built for 1/16 inch tubing will not seal on 1/8 inch tubing even with a different ferrule. Confirm the port and the tubing first, then choose between metering, splitter and shut off.

Key Specifications

ParameterValueNotes
Body materialPEEK with PTFE sealsBiocompatible flow path
Thru hole0.020 in (0.50 mm)All adjustable valves listed
Port thread1/4-28 flat bottom or 10-32 conedMust be matched to the existing port
Tubing outside diameter1/16 in or 1/8 inFixed by the valve body
Pressure rating800 psi (55 bar)Standard metering and splitter valves
High pressure splitter4000 psi (276 bar)Graduated splitter, stainless needle
Minimum controllable flow3.5 uL/minFrom 1.0 mL/min inlet with water
Internal volume1.2 uL to 7.7 uLMeasured at full open
Needle materialPEEK, or stainless steel on the splitterStainless on high pressure models
AdjustmentThumbscrew, graduated scale on the splitterRepeatable split settings

Included Models and Order Codes

The table is grouped by function. Metering valves set a continuous restriction; splitter valves divide one stream into two and are used ahead of a mass spectrometer; shut off valves stop flow quickly and are not meant for adjustment. Included fittings are listed because a valve ordered without them will not connect to the line.

Part NumberFunctionPort ThreadTubing ODInternal VolumeMax Pressure
P-445Metering valve1/4-28 flat bottom1/16 in7.7 uL800 psi
P-446Metering valve10-32 coned1/16 in7.2 uL800 psi
P-447Metering valve1/4-28 flat bottom1/8 in7.7 uL800 psi
P-450Splitter valve1/4-28 flat bottom1/16 in2.1 uL closed800 psi
P-451Splitter valve10-32 flat bottom1/16 in1.2 uL closed800 psi
P-470Graduated splitter10-32 coned1/16 in1.2 uL closed4000 psi
P-732Shut off valve1/4-28 flat bottom1/16 in2.5 uL500 psi
P-733Shut off valve1/4-28 flat bottom1/8 in10.0 uL500 psi
P-721Shut off valve, ETFE1/4-28 flat bottom1/8 in10.0 uL500 psi
P-782Shut off valve, ETFE1/4-28 flat bottom1/16 in2.5 uL500 psi
P-783Shut off valve, ETFE1/4-28 flat bottom1/8 in10.0 uL500 psi

Key Features

Fine control at low flow – flow can be trimmed to 3.5 uL per minute from a 1 mL per minute inlet, which is the range needed ahead of a mass spectrometer

PEEK and PTFE flow path – no metal in the wetted path on the standard bodies, so metal sensitive samples stay clean

0.020 inch thru hole – the same restriction across the range keeps pressure drop predictable when a valve is swapped

Graduated splitter – the P-470 scale lets a working split setting be recorded and returned to after a service

Two port styles – 1/4-28 flat bottom and 10-32 coned bodies cover most analyser and LC ports

High pressure option – 4000 psi rating on the graduated splitter with a stainless needle for higher pressure lines

Shut off to the same ports – stop valves use the same port and tubing so the block does not need a second fitting family

Fixed fittings listed – each valve states which fittings are included, so the line can be connected on arrival

Applications

Valves are placed where flow has to be trimmed or stopped without changing the tubing run.

LC and MS interfaces – a splitter valve takes a controlled fraction of the column effluent to the source and sends the rest to waste

Peristaltic pump lines – a metering valve absorbs the pulse and sets a steady flow into the mixing coil

Degasser and sparging lines – a needle valve sets gas flow so the vacuum degasser is not overrun

Valves for these lines ship alongside SUPERB PCB and SUPERB PCBA builds when the analyser also needs a new control board.

Sourcing and Cross-Reference

Replacement is decided by port, tubing and function. A 10-32 coned port cannot take a 1/4-28 flat bottom body, and a body for 1/16 inch tubing cannot be made to seal on 1/8 inch tubing. Once the port and the tube are fixed, the choice between metering, splitter and shut off follows from what the line has to do.

Internal volume matters more than it looks on a low flow system. A valve with 7.7 uL swept volume ahead of a narrow column adds delay and mixes peaks; the same job done with a 1.2 uL body keeps the injection sharp. We state the volume at full open because that is the figure that changes with the setting.

For methods that have already been validated, the graduated splitter is the safer replacement: the setting can be read off the scale and restored, which avoids a revalidation. We keep both the standard and the graduated versions available so the choice can be made on the line rather than in a catalogue.

Where a valve block sits on its own manifold board, the assembly is built through SUPERB Assembly.

Q: Can you supply a metering valve that matches the port and swept volume of the one we are replacing?

A: Yes. SUPERB Tech matches port thread, tubing diameter and swept volume against the valve being replaced before quoting.

Why Choose SUPERB for Analyser Valves

  1. Port checked first: the body is selected on port thread and tubing diameter, which is where most wrong orders start
  2. Swept volume stated: internal volume at full open is quoted so the effect on peak shape can be judged before ordering
  3. PEEK wetted path: standard bodies keep metal out of the flow path for ion sensitive work
  4. Graduated option held: a documented split setting can be restored without revalidating the method