Reflectance and Transmission Probes for Spectrometers

Probes that light a sample and read it back through one ferrule. Six illumination fibers around one read fiber, 200 to 600 um cores. Transmission dip probes from 2 to 50 mm pathlength for in line absorbance.
quote now

Product Specifications

Product Overview

A reflectance probe is two optical paths inside one ferrule. Six fibers carry light down to the sample, and one fiber in the middle carries the returning light to the spectrometer. Because the same spot is lit and read from the same direction, the measurement is stable on a moving web, a painted panel, a tablet or a powder bed, where a cuvette cannot be used at all.

Core size sets the trade between spot size and signal. A 200 um bundle keeps a small spot and holds resolution on a fiber coupled instrument, a 400 um bundle roughly doubles the light for dark or scattering samples, and a 600 um bundle is for very low light levels and short working distances. The fiber type then decides the range: a solarization resistant fiber for 200 to 1100 nm, a high OH fiber for 300 to 1100 nm, a low OH fiber for 400 to 2500 nm. One fiber cannot cover the whole span well, which is why mixed 12 fiber bundles put both ranges in the same ferrule.

A transmission probe answers a different question. The dip probe sends light across a fixed gap and back off a mirror at the tip, so the reading is absorbance through a known pathlength rather than reflectance off a surface. The tip sets the pathlength, 2 mm for concentrated dye and 10 mm for dilute solutions, and the body sets where it can be used: a 6.35 mm stainless body fits a bioreactor head port, while a 12.7 mm industrial body with a quartz window takes the temperature and pressure of a process line.

Key Specifications

ParameterValueNotes
Fiber bundle6 illumination fibers around 1 read fiberRead fiber at the centre of the ferrule
Core options200, 400 and 600 umAvantes standard bundle 200 or 400 um
Numerical aperture0.22Holds through the bundle
UV and visible range300 to 1100 nm, high OH fiberSolarization resistant option 200 to 1100 nm
Visible and NIR range400 to 2500 nm, low OH fiberLow OH keeps the water bands out
Probe ferrule6.35 mm OD x 76.2 mm, or 3.18 mm OD x 74.2 mmSmall tip probes 1.5 or 2.5 mm OD x 100 mm
Fiber length2 m standardSplit point 1 m from the probe on the R series
ConnectorsSMA 905, two legsOne leg to the source, one to the spectrometer
Operating temperature-20 to 80 C, -30 to 100 C on AvantesHigh temperature build to 200 C
Pressure, reflectance head50 bar on a 200 um head, 10 bar on a 400 um headAt 25 C, Avantes 316 stainless body
Pressure, dip probe100 psi on the 6.35 mm body, 250 psi on the 12.7 mm bodyQuartz window and O ring seal at the tip
Bend radius8, 16 or 24 cm long term for 200, 400 and 600 umShort term is half the long term value
Pathlength, transmission2, 5, 10, 25 or 50 mmTip and body ordered as separate items

Included Models and Order Codes

The first table is the reflectance family: R series laboratory probes, QR premium probes, mixed 12 fiber probes for two channel work, and the Avantes FCR probes with a 316 stainless head that takes 50 bar. The second table is the transmission family, where the body and the pathlength tip are two separate order lines, so both have to be quoted together.

Part NumberBundleCoreRangeFerruleJacketUse
R200-7-UV-VIS6 around 1200 um300 to 1100 nm6.35 x 76.2 mmPVDF zipSmall spots and thin films
R400-7-UV-VIS6 around 1400 um300 to 1100 nm6.35 x 76.2 mmPVDF zipGeneral UV and visible work
R400-7-VIS-NIR6 around 1400 um400 to 2500 nm6.35 x 76.2 mmPVDF zipColour and NIR methods
R400-7-SR6 around 1400 um200 to 1100 nm6.35 x 76.2 mmPVDF zipDeep UV without solarization
R600-7-UV-125F6 around 1600 um300 to 1100 nm3.18 x 74.2 mmPVDF zipLow light levels
R600-7-VIS-125F6 around 1600 um400 to 2500 nm3.18 x 74.2 mmPVDF zipLow light in the NIR
R600-7-SR-125F6 around 1600 um200 to 1100 nm3.18 x 74.2 mmPVDF zipUV source monitoring
RP200-7-UV-VIS6 around 1200 um300 to 1100 nm6.35 mm PEEKPVDF zipCorrosive liquid samples
R400-7-ANGLE-VIS6 around 1, 30 degree window400 um400 to 2100 nm6.35 x 76.2 mmPVDF zipPowders and slurries
R200-12-MIXED6 plus 6 around 1 plus 1200 um300 to 1100 and 400 to 2100 nm6.35 x 76.2 mmPVDF zipTwo channel instruments
R200-REF-UV-VIS6 around 1 plus reference leg200 um300 to 1100 nm6.35 x 76.2 mmPVDF zipSource drift correction
QR400-7-UV-VIS6 around 1, premium grade400 um300 to 1100 nm6.35 x 76.2 mmSilicone monocoilPlant and field use
FCR-7UVIR200-2-BX6 around 1200 um200 to 2500 nm6.35 x 50 mmStainless BX, 6.0 mm ODBroadband with pressure
FCR-7UVIR400-2-ME6 around 1400 um200 to 2500 nm6.35 x 50 mmChrome brass, 5.0 mm ODFlexible runs on a bench
FCR-7UVIR200-2-45-BX6 around 1, 45 degree window200 um200 to 2500 nm6.0 x 140 mmStainless BXPowders and thick fluids
FCR-7UVIR200-2-1.5x1006 around 1, small tip200 um200 to 2500 nm1.5 x 100 mmPTFE with PVC sleeveMedical and wafer probes
FCR-7UVIR200-2-2.5x1006 around 1, small tip200 um200 to 2500 nm2.5 x 100 mmPTFE with PVC sleeveTight fixtures
FCR-COLCollimating lensFor 6.35 mm probes200 to 2500 nmSMA at both endsAnodised bodyWorking distance above 20 mm
FCR-90-Option90 degree reflectorFor 6.35 mm probes200 to 2500 nmSlip on tipMirror at 45 degreesDownward looking heads

Transmission Dip Probes and Pathlength Tips

A transmission measurement needs two order lines: the body with its fiber legs, and the tip that sets the gap. The 6.35 mm bodies are for laboratory vessels and bioreactor ports up to 100 C, while the 12.7 mm industrial body carries a quartz window and reaches 300 C and 250 psi. Tips are not interchangeable between the two body sizes.

Part NumberBodyFiberRangePathlengthPressureTemperature
T300-RT-UV-VIS6.35 mm x 127 mm300 um UV200 to 1100 nmTip ordered separately100 psi100 C without sleeve
T300-RT-VIS-NIR6.35 mm x 127 mm300 um VIS NIR400 to 2100 nmTip ordered separately100 psi100 C without sleeve
T200-RT-VIS-NIR6.35 mm x 127 mm200 um VIS NIR400 to 2500 nmTip ordered separately100 psi100 C without sleeve
RT-2MMTip for T200 and T300Quartz200 to 2500 nm2 mm100 psi100 C
RT-5MMTip for T200 and T300Quartz200 to 2500 nm5 mm100 psi100 C
RT-10MMTip for T200 and T300Quartz200 to 2500 nm10 mm100 psi100 C
T300SLEEVESpare stainless sleeveNoneNot applicableNot applicableNot applicableNot applicable
TI300-UV-VIS12.7 mm x 127 mm300 um UV200 to 1100 nmTip ordered separately250 psi300 C body
RT-TI-2MMTip for TI300Quartz200 to 2500 nm2 mm250 psi300 C
RT-TI-5MMTip for TI300Quartz200 to 2500 nm5 mm250 psi300 C
RT-TI-10MMTip for TI300Quartz200 to 2500 nm10 mm250 psi300 C
RT-TI-25MMTip for TI300Quartz200 to 2500 nm25 mm250 psi300 C
RT-TI-50MMTip for TI300Quartz200 to 2500 nm50 mm250 psi300 C

Key Features

Lit and read at one spot – six illumination fibers ring a single read fiber, so the viewing angle stays fixed when the sample moves

Fiber chosen by range – solarization resistant for 200 to 1100 nm, high OH for 300 to 1100 nm, low OH for 400 to 2500 nm

Ferrule by access – 6.35 mm for standard holders, 3.18 mm for tight fixtures, 1.5 and 2.5 mm for wafer and medical work

Reference leg on request – a second read fiber watches the lamp, so drift shows up as a ratio rather than as a false shift in the sample

Angled windows for powders – a 30 or 45 degree window keeps the surface reflection out of the read path on slurries and tablets

Tip sets the pathlength – 2 mm for strong absorbers, 10 mm for dilute solutions, 25 and 50 mm on the industrial body

Applications

Probes are chosen together with the light source and the spectrometer slit, so an enquiry usually names the range and the sample rather than the part on its own.

Coating and film thickness – a 400 um probe at 90 degrees over a coated web, with a reference leg to hold the lamp constant

Colour on plastic and paint – a 45 degree ferrule on a bench stand, read against a white tile before each batch

In line absorbance – a 6.35 mm dip probe in a bioreactor head port, 5 mm tip for protein concentration at 280 nm

Probes and fiber assemblies ship alongside SUPERB PCB and SUPERB PCBA work when an analyser build moves from the board to the optics.

Sourcing and Cross-Reference

Two probes can carry the same core size and behave differently, because the jacket, the ferrule and the fiber type all sit in the price. We quote the range and the ferrule first, then the jacket that suits the plant: PVDF zip tube for a bench, stainless BX for a cable tray, silicone monocoil where the cable flexes all day.

The common ordering error is a probe without its tip. On the T200 and T300 bodies the pathlength tip is a separate line, and a body on its own cannot make a transmission reading. The same applies to the industrial body, where the quartz window and the O ring seal come with the tip, and the tip for one body size will not fit the other.

Spare sleeves and replacement tips are worth quoting with the first order. A dip probe in a process line loses its window to deposits long before the fiber fails, and a spare tip on the shelf turns a shutdown into a ten minute change. Lead time on the fiber assemblies is normally stock to two weeks, and we state it per line on the quotation.

Optical kits for a new instrument are packed through SUPERB Assembly, so each probe arrives with its tip, cap and label in one bag.

Q: Can you supply a 400 um reflectance probe with a reference leg, and a 5 mm tip dip probe for the same instrument?

A: Yes. SUPERB Tech quotes the body and the pathlength tip as a pair, and states the fiber range and ferrule size before the order is placed.

Why Choose SUPERB for Spectrometer Probes

  1. Range matched to the fiber: the fiber type is named per part, so a 2500 nm method is not quoted on a visible probe
  2. Body and tip quoted together: transmission probes are checked for the pathlength tip before the order is confirmed
  3. Pressure and temperature stated: 50 bar heads and 250 psi industrial bodies are separated from laboratory parts
  4. Ferrule sizes in one place: 1.5, 2.5, 3.18, 6.0 and 6.35 mm options on one page for fixture work

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Fiber Bundles and Light Guides, Fiber Collimators and Patch Cords, Quartz Flow Cells and Cuvettes, Integrating Spheres and Reflectance Standards, Photodiode Arrays and Detector Modules, Optical Filter Mounts and Lens Holders.