Contact Us
  • Home
  • COMPONENTS
  • Diaphragm Vacuum Pumps for Analyser Vacuum Lines

Diaphragm Vacuum Pumps for Analyser Vacuum Lines

Oil free vacuum for sample lines, degassers and filter housings. One stage pumps hold 70 to 160 mbar, two stage pumps reach 1.5 to 7 mbar. PTFE diaphragms and FFPM valves for solvent and acid vapours.
quote now

Product Specifications

Product Overview

A vacuum line on an analyser is usually doing one of three jobs: pulling sample through a filter housing, holding a degassing module under vacuum, or evacuating a small chamber before a measurement. Each job needs a different ultimate vacuum, and picking a pump that is deeper than the job needs costs money in seals and maintenance without improving the measurement.

The two families on this page cover both ends of that range. Single stage diaphragm pumps are the workhorses for filtration and degassing, holding 70 to 160 mbar absolute at flows from 0.7 to 7.1 m3/h. Two stage pumps reach 1.5 to 7 mbar for vacuum ovens, rotary evaporation and sample concentration, where the boiling point of the solvent has to drop far enough to evaporate at a sensible temperature.

What separates a laboratory pump from a hardware store pump is the wetted path. Diaphragms coated in PTFE, valve plates in FFPM or FKM and a PPS or PTFE head let the same pump handle solvent vapours, dilute acids and reagent mist without the diaphragm swelling and the flow falling away. That is the specification to quote when the pump sits downstream of a reagent line rather than in clean air.

Key Specifications

ParameterValueNotes
Pumping speed0.7 to 7.8 m3/h at 50 and 60 HzDepends on heads and stages
Ultimate vacuum1.5 to 160 mbar absoluteOne stage 70 to 160 mbar, two stage 1.5 to 7 mbar
Heads and stagesOne head one stage up to two heads one stageMore heads raise the flow at the same vacuum
Motor power0.12 to 0.25 kW230 V or dual voltage versions
Inlet and outletHose nozzle DN 8 to 10 mm, KF 16 optionMatch the tubing on the line
Wetted materialsPTFE coated diaphragm, FFPM or FKM valves, PPS headSolvent and acid resistance
Media temperature5 to 40 CGas inlet limit
Ambient temperature5 to 40 C operatingStorage wider
Noise45 dBA typical at 50 HzWhisper quiet series
Protection classIP 20 to IP 54Per model, check before washdown
Gas ballastAvailable on two stage modelsHelps with condensable vapours

Included Models and Order Codes

The KNF N 86 family is the small end: one head, 5.5 to 6.5 l/min, 100 or 160 mbar, and a footprint that fits inside an instrument cabinet. The Vacuubrand NT series is the larger end: 0.7 to 7.1 m3/h with chemical duty heads, up to 7.1 m3/h at 70 mbar and 1.5 mbar from the two stage model. Both blocks are quoted with the inlet fitting and the voltage the instrument provides.

Part NumberMakerPumping SpeedUltimate VacuumHeads and StagesInletUse
N 86 KT.18KNF5.5 l/min160 mbar1 head, 1 stageHose ID 4 mmDegassing and filtration
N 86 KN.18KNF6.0 l/min100 mbar1 head, 1 stageHose ID 4 mmSample pull through filters
N 86 KNDCKNF6.5 l/min100 mbar1 head, 1 stageHose ID 4 mmCabinet mount, higher flow
N 86 KTDCKNF6.0 l/min160 mbar1 head, 1 stageHose ID 4 mmSolvent vapour duty
ME 1CVacuubrand0.7 m3/h100 mbar1 head, 1 stageDN 10Small filtration jobs
ME 2C NTVacuubrand2.1 m3/h70 mbar1 head, 1 stageDN 10Vacuum filtration
ME 4C NTVacuubrand3.9 m3/h70 mbar2 heads, 1 stageDN 10Larger filter housings
ME 8C NTVacuubrand7.1 m3/h70 mbar2 heads, 1 stageDN 10Multi port manifolds
MZ 2C NTVacuubrand2.3 m3/h7 mbar2 heads, 2 stagesDN 10 or KF 16Vacuum ovens and rotovaps
MD 4C NTVacuubrand3.4 m3/h1.5 mbar2 heads, 2 stagesDN 10 or KF 16Deeper vacuum, solvent recovery

Key Features

Oil free by construction – no oil mist to contaminate a sample line and no oil change in the maintenance schedule

Chemical duty wetted path – PTFE coated diaphragms, FFPM valves and a PPS or PTFE head for solvent and acid vapours

Two stage where it matters – 7 mbar and 1.5 mbar options when the job is evaporation rather than filtration

Flow quoted at atmospheric pressure – the number on the datasheet is the free air flow, and the curve shows what remains at working vacuum

Small footprint for cabinet builds – the single head models fit inside an instrument enclosure with the inlet and outlet on the same face

Gas ballast on two stage models – condensable vapours pass through instead of collecting in the head

Applications

The pump is usually the last item chosen on a sample line, after the filter, the degasser and the valve, and the flow at working vacuum is what ties them together.

Inline degassing – a single stage pump holding a membrane degasser at 70 to 160 mbar upstream of the detector

Filtration and sample prep – a pump pulling reagent or sample through a filter housing at a controlled flow

Vacuum ovens and concentration – a two stage pump at 1.5 to 7 mbar for solvent removal at moderate temperature

Instrument builders pair these pumps with SUPERB PCB and SUPERB PCBA assemblies, so the vacuum line and the control board are quoted together.

Sourcing and Cross-Reference

Quote the working vacuum, not the ultimate vacuum, when a pump sits behind a filter. A pump rated at 70 mbar will hold 200 to 300 mbar behind a loaded filter, and the flow curve at that point is the number that decides whether the line keeps up. Sending the filter specification with the pump enquiry is the fastest way to a right answer.

Diaphragm life is a consumable cost, and it moves with the vapour load. A pump handling only air runs for years on one set of diaphragms; the same pump handling chlorinated solvent mist may need a set a year. We state the diaphragm and valve set part number next to the pump so the maintenance budget is visible at quotation rather than at the first failure.

For a cabinet build there are two mechanical points worth settling early. The outlet needs somewhere to vent, because a pump pushing into a closed space heats the cabinet; and the inlet trap, if one is used, has to be reachable without removing the pump. Both affect the mounting plate more than the pump choice.

Pump, tubing and mounting plate arrive as one kit through SUPERB Assembly, matched to the enclosure cutouts.

Q: Can you supply a chemical duty diaphragm pump that holds 100 mbar behind a filter housing and runs on 24 V DC?

A: Yes. SUPERB Tech quotes the pump against the working vacuum behind the filter, and names the diaphragm and valve set for the vapour load.

Why Choose SUPERB for Diaphragm Vacuum Pumps

  1. Working point quoted: flow at the vacuum the line actually sees, not only the free air figure
  2. Chemical duty stated: diaphragm, valve and head materials named per model
  3. Consumables listed: diaphragm and valve sets quoted with the pump so the maintenance cost is known
  4. Cabinet fit checked: inlet, outlet and trap position reviewed against the mounting plate before the order

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Peristaltic and Diaphragm Micro Pumps, Inline Degassing Modules, Inline Filters and Frits, Bubble Traps and Debubblers, Peristaltic Pump Tubing and Heads, Immersion Assemblies and Sample Probes.