Diaphragm Vacuum Pumps for Analyser Vacuum Lines
Product Specifications
Product Overview
A vacuum line on an analyser is usually doing one of three jobs: pulling sample through a filter housing, holding a degassing module under vacuum, or evacuating a small chamber before a measurement. Each job needs a different ultimate vacuum, and picking a pump that is deeper than the job needs costs money in seals and maintenance without improving the measurement.
The two families on this page cover both ends of that range. Single stage diaphragm pumps are the workhorses for filtration and degassing, holding 70 to 160 mbar absolute at flows from 0.7 to 7.1 m3/h. Two stage pumps reach 1.5 to 7 mbar for vacuum ovens, rotary evaporation and sample concentration, where the boiling point of the solvent has to drop far enough to evaporate at a sensible temperature.
What separates a laboratory pump from a hardware store pump is the wetted path. Diaphragms coated in PTFE, valve plates in FFPM or FKM and a PPS or PTFE head let the same pump handle solvent vapours, dilute acids and reagent mist without the diaphragm swelling and the flow falling away. That is the specification to quote when the pump sits downstream of a reagent line rather than in clean air.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Pumping speed | 0.7 to 7.8 m3/h at 50 and 60 Hz | Depends on heads and stages |
| Ultimate vacuum | 1.5 to 160 mbar absolute | One stage 70 to 160 mbar, two stage 1.5 to 7 mbar |
| Heads and stages | One head one stage up to two heads one stage | More heads raise the flow at the same vacuum |
| Motor power | 0.12 to 0.25 kW | 230 V or dual voltage versions |
| Inlet and outlet | Hose nozzle DN 8 to 10 mm, KF 16 option | Match the tubing on the line |
| Wetted materials | PTFE coated diaphragm, FFPM or FKM valves, PPS head | Solvent and acid resistance |
| Media temperature | 5 to 40 C | Gas inlet limit |
| Ambient temperature | 5 to 40 C operating | Storage wider |
| Noise | 45 dBA typical at 50 Hz | Whisper quiet series |
| Protection class | IP 20 to IP 54 | Per model, check before washdown |
| Gas ballast | Available on two stage models | Helps with condensable vapours |
Included Models and Order Codes
The KNF N 86 family is the small end: one head, 5.5 to 6.5 l/min, 100 or 160 mbar, and a footprint that fits inside an instrument cabinet. The Vacuubrand NT series is the larger end: 0.7 to 7.1 m3/h with chemical duty heads, up to 7.1 m3/h at 70 mbar and 1.5 mbar from the two stage model. Both blocks are quoted with the inlet fitting and the voltage the instrument provides.
| Part Number | Maker | Pumping Speed | Ultimate Vacuum | Heads and Stages | Inlet | Use |
|---|---|---|---|---|---|---|
| N 86 KT.18 | KNF | 5.5 l/min | 160 mbar | 1 head, 1 stage | Hose ID 4 mm | Degassing and filtration |
| N 86 KN.18 | KNF | 6.0 l/min | 100 mbar | 1 head, 1 stage | Hose ID 4 mm | Sample pull through filters |
| N 86 KNDC | KNF | 6.5 l/min | 100 mbar | 1 head, 1 stage | Hose ID 4 mm | Cabinet mount, higher flow |
| N 86 KTDC | KNF | 6.0 l/min | 160 mbar | 1 head, 1 stage | Hose ID 4 mm | Solvent vapour duty |
| ME 1C | Vacuubrand | 0.7 m3/h | 100 mbar | 1 head, 1 stage | DN 10 | Small filtration jobs |
| ME 2C NT | Vacuubrand | 2.1 m3/h | 70 mbar | 1 head, 1 stage | DN 10 | Vacuum filtration |
| ME 4C NT | Vacuubrand | 3.9 m3/h | 70 mbar | 2 heads, 1 stage | DN 10 | Larger filter housings |
| ME 8C NT | Vacuubrand | 7.1 m3/h | 70 mbar | 2 heads, 1 stage | DN 10 | Multi port manifolds |
| MZ 2C NT | Vacuubrand | 2.3 m3/h | 7 mbar | 2 heads, 2 stages | DN 10 or KF 16 | Vacuum ovens and rotovaps |
| MD 4C NT | Vacuubrand | 3.4 m3/h | 1.5 mbar | 2 heads, 2 stages | DN 10 or KF 16 | Deeper vacuum, solvent recovery |
Key Features
Oil free by construction – no oil mist to contaminate a sample line and no oil change in the maintenance schedule
Chemical duty wetted path – PTFE coated diaphragms, FFPM valves and a PPS or PTFE head for solvent and acid vapours
Two stage where it matters – 7 mbar and 1.5 mbar options when the job is evaporation rather than filtration
Flow quoted at atmospheric pressure – the number on the datasheet is the free air flow, and the curve shows what remains at working vacuum
Small footprint for cabinet builds – the single head models fit inside an instrument enclosure with the inlet and outlet on the same face
Gas ballast on two stage models – condensable vapours pass through instead of collecting in the head
Applications
The pump is usually the last item chosen on a sample line, after the filter, the degasser and the valve, and the flow at working vacuum is what ties them together.
Inline degassing – a single stage pump holding a membrane degasser at 70 to 160 mbar upstream of the detector
Filtration and sample prep – a pump pulling reagent or sample through a filter housing at a controlled flow
Vacuum ovens and concentration – a two stage pump at 1.5 to 7 mbar for solvent removal at moderate temperature
Instrument builders pair these pumps with SUPERB PCB and SUPERB PCBA assemblies, so the vacuum line and the control board are quoted together.
Sourcing and Cross-Reference
Quote the working vacuum, not the ultimate vacuum, when a pump sits behind a filter. A pump rated at 70 mbar will hold 200 to 300 mbar behind a loaded filter, and the flow curve at that point is the number that decides whether the line keeps up. Sending the filter specification with the pump enquiry is the fastest way to a right answer.
Diaphragm life is a consumable cost, and it moves with the vapour load. A pump handling only air runs for years on one set of diaphragms; the same pump handling chlorinated solvent mist may need a set a year. We state the diaphragm and valve set part number next to the pump so the maintenance budget is visible at quotation rather than at the first failure.
For a cabinet build there are two mechanical points worth settling early. The outlet needs somewhere to vent, because a pump pushing into a closed space heats the cabinet; and the inlet trap, if one is used, has to be reachable without removing the pump. Both affect the mounting plate more than the pump choice.
Pump, tubing and mounting plate arrive as one kit through SUPERB Assembly, matched to the enclosure cutouts.
Q: Can you supply a chemical duty diaphragm pump that holds 100 mbar behind a filter housing and runs on 24 V DC?
A: Yes. SUPERB Tech quotes the pump against the working vacuum behind the filter, and names the diaphragm and valve set for the vapour load.
Why Choose SUPERB for Diaphragm Vacuum Pumps
- Working point quoted: flow at the vacuum the line actually sees, not only the free air figure
- Chemical duty stated: diaphragm, valve and head materials named per model
- Consumables listed: diaphragm and valve sets quoted with the pump so the maintenance cost is known
- Cabinet fit checked: inlet, outlet and trap position reviewed against the mounting plate before the order
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Peristaltic and Diaphragm Micro Pumps, Inline Degassing Modules, Inline Filters and Frits, Bubble Traps and Debubblers, Peristaltic Pump Tubing and Heads, Immersion Assemblies and Sample Probes.