Mounting Brackets and DIN Rail Clips for Enclosures
Product Specifications
Product Overview
A DIN rail is a piece of formed steel. On its own it holds nothing. The parts that turn it into a mounting system are the terminal blocks that clip onto it and the end brackets that stop them moving. An end bracket is a small moulded part with a foot that hooks under the rail lip and a screw or a snap feature that locks it to the rail. It costs very little and it decides whether a bank of terminals stays where the drawing puts it after a cabinet has been on a truck.
The width of the bracket is the first figure to look at. The Phoenix CLIPFIX 35 is 9.5 mm wide and 54.6 mm high, with a depth of 33.5 mm on NS 35/7.5 rail and 41 mm on NS 35/15. The CLIPFIX 35-5 is 5.2 mm wide and 48.6 mm high, with a depth of 37.1 mm and 44.6 mm on the two rail heights. The narrower part is the one to use when the terminal pitch is 5.2 mm, because a 9.5 mm bracket at the end of a 5.2 mm row pushes the marking strip half a pitch out of line and the first label no longer sits over the first terminal.
The Weidmuller WEW 35/2 is 8 mm wide, 56 mm high and 46.5 mm deep on TS 35 rail, in Wemid, rated for continuous operation from -50 to 100 C. It is screwed to the rail rather than snapped, with a tightening torque of 0.5 to 1 Nm and a screw fixing interlock, which is the version to choose where the bank is long and the rail is expected to see vibration. The same part in the V0 grade, WEW 35/2 V0 GF SW, keeps the 8 mm width and the 46.5 mm depth and raises the continuous temperature to 130 C with a V-0 flammability rating.
The rail itself is standardised, which is why brackets from three makers fit the same steel. EN 60715 sets the 35 mm width and the two profile heights: 7.5 mm for the shallow rail and 15 mm for the deep one. The Phoenix NS 35/7.5 PERF is a perforated rail, 35 mm wide, 7.5 mm deep and 2000 mm long, in galvanised and passivated steel, with 15 mm by 6.2 mm holes on a 25 mm pitch. Its short-time withstand current for one second is 1.92 kA, against an equivalent copper cross section of 16 mm2. That is a rail figure, not a terminal figure, and it is the one to quote when a fault current has to pass through the rail rather than through a conductor.
Mounting brackets are the other half of the page. The same moulded parts are used to hold a rail off a panel, to fix a terminal bank to a cabinet wall, and to park spare bridges and test plugs. The CLIPFIX range carries a marking option and a parking option for FBS bridges, which is why the bracket at the end of a row often carries the row label. Where the bracket is used as a stand off, the depth on rail is the figure that decides clearance behind the terminals, and that clearance is what the door swing and the cable bend radius are checked against.
The practical point on any rail build is that the bracket is fitted last and tightened after the bank is complete. A bracket pulled up hard before the last terminal is landed bows the rail, and a bowed rail loses contact at the middle terminals, which shows up as a hot spot rather than as a loose part. On a long bank the rail is also worth cutting to length rather than joining, because a joint in the rail is a step that every terminal has to cross.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Rail standard | EN 60715, 35 mm profile | All parts |
| Rail heights | 7.5 mm and 15 mm | NS 35/7.5 and NS 35/15 |
| End bracket widths | 5.2 mm, 8 mm, 9.5 mm | By part |
| Bracket heights | 48.6 mm, 54.6 mm, 56 mm | By part |
| Depth on 7.5 mm rail | 33.5 mm, 35.3 mm, 37.1 mm, 46.5 mm | By part |
| Depth on 15 mm rail | 41 mm, 44.6 mm, 46.5 mm | By part |
| Bracket materials | PA, Wemid | By part |
| Flammability | HB, V0 | By part |
| Continuous temperature | -50 to 100 C, -50 to 130 C, up to 130 C index | By part |
| Screw torque on the rail | 0.5 to 1 Nm | WEW 35/2 |
| Rail material | Steel, galvanised and passivated | NS 35/7.5 |
| Rail hole pattern | 15 x 6.2 mm, 25 mm pitch | NS 35/7.5 PERF |
| Rail short-time current, 1 s | 1.92 kA at 16 mm2 equivalent copper | NS 35/7.5 PERF |
| Rail length | 2000 mm | NS 35/7.5 PERF |
Included Models and Order Codes
The rows below are the brackets and rail we quote most often. Width, height and depth on rail are given per part because those three figures decide whether the bank fits the cabinet, and a dash means the maker does not publish that figure.
| Part Number | Type | Width | Height | Depth on Rail | Material | Notes |
|---|---|---|---|---|---|---|
| 3022218 | CLIPFIX 35 end bracket | 9.5 mm | 54.6 mm | 33.5 mm on 7.5, 41 mm on 15 | PA, gray | Marking option, wide body |
| 3022276 | CLIPFIX 35-5 end bracket | 5.2 mm | 48.6 mm | 37.1 mm on 7.5, 44.6 mm on 15 | PA, V0, gray | Parking option for FBS bridges |
| 1061200000 | WEW 35/2 end bracket | 8 mm | 56 mm | 46.5 mm on TS 35 | Wemid, dark beige | Screw fixing, 0.5 to 1 Nm, -50 to 100 C |
| 1479000000 | WEW 35/2 V0 GF SW | 8 mm | 56 mm | 46.5 mm on TS 35 | Wemid, V0, black | Continuous 130 C |
| 0801733 | NS 35/7.5 PERF rail | 35 mm | 7.5 mm | 2000 mm long | Steel, galvanised | 15 x 6.2 mm holes, 25 mm pitch, 1.92 kA for 1 s |
Key Features
Width matched to terminal pitch – 5.2 mm, 8 mm and 9.5 mm brackets are listed, because the bracket at the end of a row sets the pitch of the marking strip.
Depth stated for both rail heights – 33.5 mm and 41 mm on the 9.5 mm part, 37.1 mm and 44.6 mm on the 5.2 mm part, so the clearance behind the rail is known before the door is sized.
Screw and snap fixing – The WEW 35/2 is screwed to the rail at 0.5 to 1 Nm, which is the version to use on a long bank that sees vibration.
V0 grade available – The same 8 mm bracket comes in a V0 grade rated to 130 C, so a hot cabinet does not force a different rail layout.
Rail rated for fault current – The 35 mm rail is rated at 1.92 kA for one second, which is the figure that applies when fault current passes through the rail.
Standard profile – Every bracket and rail on the page follows EN 60715, so parts from different makers fit the same 35 mm steel.
Applications
These parts are used wherever a terminal bank, a relay row or a power supply has to be fixed to a panel and stay fixed.
Control cabinets – A bank of 5.2 mm terminals ends in a 5.2 mm CLIPFIX 35-5 bracket, so the marking strip stays in line and the row label sits over the first terminal.
Machine and skid builds – An 8 mm screwed bracket on TS 35 rail holds a long relay row through vibration, with the torque called out at 0.5 to 1 Nm.
Rail mounted power supplies – A 9.5 mm bracket at each end of a 35 mm rail keeps a power supply and its terminal bank from sliding when a cable is pulled.
Rail hardware is quoted against the rail that is already on the panel, so the depth on rail is checked against the SUPERB PCB envelope before the cabinet layout is fixed. On the SUPERB PCBA route the end brackets go on after the terminals are wired, because a bracket tightened down before the last terminal is landed is a bracket that gets loosened again.
Sourcing and Cross-Reference
A bracket is bought by rail and by width. The rail is standard, the width is not, and the width is what the drawing usually leaves out. When a bracket is replaced on a cabinet that is already built, the rail type and the depth on rail are the two figures to check first, because a 46.5 mm deep part where a 33.5 mm part was fitted will touch the door before it touches the terminals.
The second point is the fixing method. A snapped bracket is fast to fit and easy to move. A screwed bracket holds a long bank through vibration but needs a torque figure on the drawing. On a rail that carries a marking strip, the bracket also carries the row label, so the width has to match the terminal pitch or the label no longer lines up with the first pole.
The third point is the rail itself. A 35 mm rail is a conductor as well as a support, so its short-time current rating matters where fault current passes through it. Cutting the rail to length is better than joining it, and the cut end is worth deburring, because a burr on the rail lip is what makes a terminal sit at an angle. We quote the rail, the brackets and the terminals as one set, because the three are ordered together and fitted together.
SUPERB Assembly fits the first rail, slides a full bank of terminals onto it and pulls the end brackets up by hand before the screws are set, because a rail that bows under a tight bracket loses contact at the middle terminals.
Q: Can you supply 5.2 mm end brackets for NS 35/7.5 rail to match a 5.2 mm terminal pitch, and confirm the depth on rail and the fixing torque?
A: Send the rail type, the number of terminals in the bank and the depth behind the rail. The SUPERB Tech desk quotes the bracket with its width and its depth on the rail, because a 9.5 mm bracket on a 5.2 mm terminal pitch throws the marking strip out of line.
Why Buy DIN Rail Clips and Mounting Brackets Through SUPERB
- Width matched to the bank: Brackets are quoted in 5.2 mm, 8 mm and 9.5 mm so the end of a row lines up with its terminals.
- Depth checked before the door: Depth on both rail heights is stated, so the clearance behind the rail is known before the cabinet is closed up.
- Fixing method stated: Snap and screwed versions are separated, with the torque figure for the screwed part on the quote.
- Rail rated for current: The 35 mm rail is quoted with its one second short-time rating, because the rail is part of the fault path.
- Rail, bracket and terminal as one set: The three parts are ordered together and fitted together, so a 5.2 mm pitch is not delivered with a 9.5 mm bracket.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Screw Terminal Blocks and Pluggable Connectors for Field Wiring, DIN and Circular Connectors for Panel Wiring, Enclosure Handles and Corner Guards for Portable Units, Standoffs Spacers and Mounting Hardware for Board Stacks, PCB Card Guides and Board Retainers for Rack Cards, BOM Shortage Recovery.