Butt Splices and Crimp Connectors for Wire Joins
Product Specifications
Product Overview
A butt splice is the plainest connector in a harness: a copper tube with a wire stop in the middle, an insulation sleeve over it, and two crimp stations, one at each end. The two wires enter from opposite ends and meet at the stop. That is the whole part, and almost every field failure traced to one comes down to three things: the wrong wire range, the wrong strip length, or a crimp made in the wrong die station.
The insulation sleeve is where the families differ. Vinyl is the cheapest and the most common, and it is rated to 105 C with a flammability rating of V-2 or HB. Nylon costs a little more and brings V-0 with it, which is why it turns up in cabinets that have to pass a flame test. Heat shrink polyolefin with an adhesive lining is the third family, and its job is not insulation but sealing: when the tube is shrunk, the adhesive flows into the joint and the splice resists water and salt. On a machine that gets washed down, or a masthead box that breathes every night, the sealed part is the only one worth quoting.
The Panduit BSV range is the vinyl family and it covers 22-18 in red, 16-14 in blue and 12-10 in yellow. Lengths are 1.03 in, 1.04 in and 1.17 in, and the maximum wire insulation diameter is 0.170 in, 0.211 in and 0.260 in. The 22-18 and 16-14 parts carry 600 V, and the 12-10 part carries 600 V with stranded wire but drops to 300 V when a 10 AWG solid wire is used. That note is on the maker drawing, not in the catalogue headline, and it is the sort of detail that decides whether a panel passes its inspection.
The BSN range is the nylon family, and it adds the 26-22 size that the vinyl range does not have. BSN22-C is 0.79 in long, BSN18-C and BSN14-C are 1.15 in, and BSN10-L is 1.14 in. The 22-18 part has a 0.13 in barrel bore and a 0.20 in barrel outside diameter, with a maximum insulation diameter of 0.115 in. All four are rated 600 V and 105 C with a V-0 sleeve, and the strip length is 9/32 in rather than the 5/16 in used on the vinyl parts. Two families that look alike on a bench take different strip lengths, which is exactly how a good splice gets a bad crimp.
The sealed family on this page is built from two makers. The 3M MH parts are a seamless copper barrel with an adhesive lined polyolefin sleeve: MH18BCK for 22-18, MH14BCK for 16-14 and MH10BCK for 12-10, at 1.2 in, 1.3 in and 1.5 in overall, with barrel bores of 0.062 in, 0.095 in and 0.142 in. Strip length is 3/8 in, the rating is 600 V for building wire and 1000 V for signs and fixtures, and the operating temperature is 105 C. The Molex Perma-Seal parts do the same job with a NiAc sleeve and a hot melt lining, and they add the step down versions that join a 22-18 wire to a 16-14 wire, or a 10-12 wire to a 14-16 wire, without doubling the wire over.
Step down splices are worth a paragraph of their own, because they solve a problem that a standard butt splice cannot. A harness that taps a 22 AWG signal wire into an 18 AWG return, or a 12 AWG feed into a 16 AWG tail, has two different barrel bores at the two ends. Forcing both wires into one bore either leaves the small wire loose or bunches the strands on the large one. Molex 19164-0043 takes 22-18 on one side and 16-14 on the other, and 191640077 takes 10-12 on one side and 14-16 on the other with a maximum wire insulation diameter of 6.99 mm.
The crimp itself is where the joint is made or lost. Every part on this page has a recommended tool and a recommended station, and the die has a colour code that matches the sleeve. The wire has to reach the stop, the insulation must not enter the barrel, and the crimp is made once, not twice. A pull test on the first unit of a build is cheap, and it catches the two failures that a visual check cannot: an under crimp that looks neat and a wrong die that flattened the barrel without gripping the strands.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Connector type | Butt splice, butted seam or seamless barrel | All parts |
| Wire range | 26-22, 22-18, 16-14, 12-10 AWG | By part |
| Insulation materials | Vinyl, nylon, heat shrink polyolefin, NiAc | By family |
| Maximum voltage | 600 V per UL 486C | Vinyl, nylon, sealed |
| Voltage exception | 300 V with 10 AWG solid wire | BSV10X-Q |
| Maximum temperature | 105 C (221 F) | All parts |
| Flammability of sleeve | V-2 or HB on vinyl, V-0 on nylon | BSV and BSN |
| Barrel construction | Brazed seam on vinyl and nylon, seamless on sealed | By family |
| Wire stop | Internal stop in the barrel centre | All parts |
| Strip length | 5/16 in vinyl, 9/32 in nylon, 3/8 in sealed | By family |
| Maximum wire insulation diameter | 0.170, 0.211, 0.260 in on vinyl | BSV series |
| Sealing | Adhesive lined polyolefin, resistant to water and salt | MH and Perma-Seal |
| Crimp tools | CT-100A, CT-1550, CT-1551, TH-440, TH-450, 640017400 | By part |
| Approvals | UL 486C, CSA C22.2 No.65, UL E23438, UL E32244 | By family |
| Shelf life of sealed parts | 5 years in controlled storage | 3M MH series |
Included Models and Order Codes
The rows below are the splices we quote most often. Wire range, sleeve material and length are given per part because those three figures decide whether the joint fits the loom, and a dash means the maker does not publish that figure.
| Part Number | Type | Wire Range | Sleeve | Length | Notes |
|---|---|---|---|---|---|
| BSV18X-LY | Butt splice, butted seam | 22-18 AWG | Vinyl, red | 1.03 in, max ins 0.170 in | 600 V, strip 5/16 in |
| BSV14X-L | Butt splice, butted seam | 16-14 AWG | Vinyl, blue | 1.04 in, max ins 0.211 in | 600 V, strip 5/16 in |
| BSV10X-Q | Butt splice, butted seam | 12-10 AWG | Vinyl, yellow | 1.17 in, max ins 0.260 in | 300 V with 10 AWG solid |
| BSN22-C | Butt splice, brazed seam | 26-22 AWG | Nylon, yellow | 0.79 in, max ins 0.080 in | 600 V, V-0 sleeve |
| BSN18-C | Butt splice, brazed seam | 22-18 AWG | Nylon, red | 1.15 in, bore 0.13 in | 600 V, strip 9/32 in |
| BSN14-C | Butt splice, brazed seam | 16-14 AWG | Nylon, blue | 1.15 in, max ins 0.148 in | 600 V, V-0 sleeve |
| BSN10-L | Butt splice, brazed seam | 12-10 AWG | Nylon, yellow | 1.14 in, max ins 0.210 in | 600 V, 0.04 in copper wall |
| MH18BCK | Sealed butt splice, seamless | 22-18 AWG | Heat shrink, red | 1.2 in, barrel 0.28 in | Bore 0.062 in, 600 V, strip 3/8 in |
| MH14BCK | Sealed butt splice, seamless | 16-14 AWG | Heat shrink, blue | 1.3 in, barrel 0.30 in | Bore 0.095 in, 600 V |
| MH10BCK | Sealed butt splice, seamless | 12-10 AWG | Heat shrink, yellow | 1.5 in, barrel 0.38 in | Bore 0.142 in, 600 V |
| 19164-0013 | Sealed butt splice, Perma-Seal | 22-18 AWG | NiAc, red | Bulk carton | -10 to 105 C, wire ins 4.70 mm max |
| 19164-0014 | Sealed butt splice on tape | 22-18 AWG | NiAc, red | Mylar tape carrier | For automatic crimp machines |
| 19164-0043 | Step down butt splice | 22-18 to 16-14 AWG | NiAc, blue | Two bores in one barrel | Joins unlike wire gauges |
| 191640077 | Step down butt splice | 10-12 to 14-16 AWG | NiAc | Wire ins 6.99 mm max | -10 to 105 C |
Key Features
Wire stop inside the barrel – Every splice on the page has a centre stop, so both wires reach the same depth and the crimp lands over strands rather than over air.
Three sleeve families – Vinyl, nylon and adhesive lined polyolefin are listed with their own temperature, flammability and sealing behaviour, so a flame test and a wash down do not pull the part in two directions.
Sealed joints for wet locations – The heat shrink parts flow adhesive into the crimp when they are shrunk, which is what keeps water and salt out of a joint on a mast or a wash down line.
Step down versions – 19164-0043 and 191640077 join a large wire to a small one with a bore for each, instead of forcing both into one barrel.
Strip length stated per family – 5/16 in on vinyl, 9/32 in on nylon and 3/8 in on the sealed parts, because one strip length across a mixed harness leaves copper outside the crimp.
Voltage note on the 12-10 vinyl part – 600 V applies to stranded wire and 300 V to 10 AWG solid, which is the figure the inspection sheet has to use.
Applications
These parts are used wherever a wire has to be lengthened, repaired or joined inside a harness and the joint has to pass a pull test and a voltage check.
Cabinet and panel harness – A 16-14 nylon splice on a 1.15 in barrel takes a 9/32 in strip and holds 600 V, which covers the control wiring in a machine cabinet.
Wet and outdoor joints – An MH14BCK sealed splice on a 16-14 wire shrinks down over the crimp and keeps water out of a joint that sits under a gland.
Mixed gauge taps – A step down splice joins a 12 AWG feed to a 16 AWG tail with a barrel bore for each wire, so neither end is loose.
A splice is chosen against the wire and the space around it, so the barrel length and the insulation diameter are checked against the SUPERB PCB harness drawing before the first crimp is made. On the SUPERB PCBA route the splices sit in the cable loom that leaves the board, and they are crimped after the connector is landed so the loom is not pulled through a finished assembly.
Sourcing and Cross-Reference
A splice is bought by wire, not by part number alone. The same 22-18 barrel comes in vinyl, nylon and sealed versions, and the three take different strip lengths and different crimp tools. When a splice is replaced on a harness that is already qualified, the wire range and the insulation diameter are the two figures to check first, because a 0.211 in sleeve will not enter a 0.170 in boot and a 26-22 part will not grip an 18 AWG strand bundle.
The second point is the joint environment. A dry cabinet joint can be vinyl and nothing is lost. A joint under a gland, on a mast or on a wash down line needs the adhesive lined part, because the failure mode there is not a loose wire but a corroded joint that reads fine on the bench and fails a year later. If the harness is already built, adding heat shrink over a plain splice is a second best route, and it is worth saying so on the drawing rather than leaving it to the line.
The third point is the record. Every part on this page has a wire range, a strip length, a tool and a die colour, and those four lines belong on the work instruction. We quote the splice together with the tool and the die, because a box of correct parts crimped with the wrong station is a batch of joints that passes a visual check and fails a pull test.
SUPERB Assembly pulls one splice from every reel and every box on the first build, cuts it open and checks the crimp height and the wire stop position, because a barrel that was crimped with the wrong die looks correct from the outside.
Q: Can you supply sealed butt splices that join a 22 AWG wire to a 16 AWG wire in a wet cabinet, and confirm the strip length and the crimp tool?
A: Send the wire gauge, the insulation diameter, the voltage on the circuit and whether the joint sits in a wet or a dry place. The SUPERB Tech desk quotes the splice with its strip length and its crimp tool, because a 22-18 part crimped with a 16-14 die is a joint that pulls out at 20 N instead of holding the wire.
Why Buy Butt Splices and Crimp Connectors Through SUPERB
- Wire range checked first: The splice is quoted against the wire and the insulation diameter, which is where a 0.170 in sleeve gets ordered for a 0.211 in wire.
- Sleeve matched to the location: Vinyl, nylon and sealed parts are on one page, so a flame test and a wet location are not forced onto the same connector.
- Strip length and tool on the quote: Each family carries its own strip length and tool, so the work instruction and the purchase order agree.
- Step down parts in the same order: The mixed gauge splices are quoted with the standard ones, because a harness usually needs both.
- Crimp checked on the first unit: A sample is cut open and checked for crimp height and wire stop position, because an under crimp looks correct from outside.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Wire Ferrules and Crimp Sleeves for Terminal Blocks, Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Wire to Board Crimp Housings and Headers for Harness Builds, Heat Shrink Tubing and Sleeves for Harness Protection, Cable Clamps and Harness Ties for Internal Wiring, BOM Shortage Recovery.