Contact Us
  • Home
  • COMPONENTS
  • Heat Shrink Tubing and Sleeves for Harness Protection

Heat Shrink Tubing and Sleeves for Harness Protection

Heat shrink is chosen by recovered diameter, not by the size printed on the reel, and that is where most harness drawings go wrong. The 2:1 tubing here runs from 1.17 mm to 50.8 mm expanded, with recovered diameters down to half of that and walls from 0.41 mm to 1.14 mm. The 3:1 adhesive lined tubing runs from 3.18 mm to 38.1 mm expanded, with a meltable inner wall that seals the joint as it shrinks. Expanded diameter, recovered diameter, recovered wall and minimum shrink temperature are given per size.
quote now

Product Specifications

Product Overview

A piece of heat shrink tubing is a ratio, not a size. A 2:1 sleeve will recover to half of its supplied inside diameter; a 3:1 sleeve to a third. That single figure decides whether the sleeve grips the joint or sits loose on it, and it is the figure that is missing when a harness comes back with a sleeve that slid off. The size printed on the reel is the expanded diameter, which is the size that has to go over the connector, not the size that has to grip the splice.

The 2:1 tubing on this page is 3M FP-301, a flexible polyolefin with a 900 V/mil dielectric strength and a continuous rating from -55 to 135 C. Minimum shrink temperature is 100 C. It meets AMS-DTL-23053/5 Class 1 and Class 2, is UL recognised to 600 V and CSA certified. The range starts at 3/64 in with a 1.17 mm expanded diameter and a 0.58 mm recovered diameter, and runs to 4 in with a 101.6 mm expanded diameter and a 50.8 mm recovered diameter. The wall goes from 0.41 mm on the smallest size to 1.40 mm on the largest.

The numbers that matter on a harness are the recovered diameter and the wall. A 6.35 mm sleeve recovers to 3.18 mm with a 0.64 mm wall, so it grips a 3 mm splice and covers it with 0.64 mm of insulation. The same sleeve on an 8 mm splice will not recover far enough to grip, and it will slide. A 12.7 mm sleeve recovers to 6.35 mm, which covers a 6 mm splice, but the wall is the same 0.64 mm, so the abrasion protection does not improve with the size. Where more wall is needed, the answer is a heavier wall product rather than a larger size.

The 3:1 tubing is 3M EPS-300, a dual wall part with an adhesive inner layer that melts at about 110 C and fills the gap around the joint. It is rated from -55 to 110 C with a 500 V/mil dielectric strength, is UL recognised under file E-157227 and CSA certified, and is flame retardant to 600 V. The range runs from 3.18 mm expanded with a 1.02 mm recovered diameter and a 1.02 mm total wall, to 38.1 mm expanded with a 12.95 mm recovered diameter and a 2.54 mm total wall.

The 3:1 part is the one to use where the joint has to be sealed rather than just covered. A splice that sees moisture, a connector backshell that has to pass an immersion test, or a repair on a cable that will be buried in a conduit all need the adhesive layer, because the shrink alone leaves a capillary path under the sleeve. The cost is a higher shrink temperature and a shorter working window, so the heat gun has to be set and the sleeve rotated while it recovers.

The practical rules are short. Cut the sleeve long enough to overlap the insulation by at least one recovered diameter on each side, because a sleeve that ends exactly at the splice edge peels back. Shrink from the middle outwards so the air escapes at both ends. And do not stretch the sleeve while it is hot, because a stretched sleeve recovers thinner and the wall figure on the data sheet no longer applies.

Key Specifications

ParameterValueApplies to
Shrink ratio2:1, 3:1By product
MaterialFlexible polyolefin, adhesive lined on the 3:1 partBy product
Expanded diameter range1.17 mm to 101.6 mm, and 3.18 mm to 38.1 mmFP-301 and EPS-300
Recovered diameterHalf of expanded on 2:1, one third on 3:1By product
Recovered wall0.41 mm to 1.40 mm, and 1.02 mm to 2.54 mm totalBy product
Continuous temperature-55 to 135 C, -55 to 110 CFP-301 and EPS-300
Minimum shrink temperature100 CFP-301
Dielectric strength900 V/mil, 500 V/milFP-301 and EPS-300
Voltage rating600 VBoth products
UL and CSAUL E-39100, CSA LR38227, UL E-157227By product
SpecificationAMS-DTL-23053/5 Class 1 and Class 2FP-301
Longitudinal changePlus or minus 5 percentFP-301
ColoursBlack, clear, plus blue, green, red, white, yellowFP-301

Included Models and Order Codes

The rows below are the 2:1 sizes we quote most often. Expanded diameter, recovered diameter and recovered wall are given per size, because a sleeve that does not recover far enough to grip is a sleeve that slides off the joint.

Ordering SizeExpanded IDRecovered IDRecovered WallTypical Use
3/32 in2.36 mm1.17 mm0.51 mmSingle 0.5 mm wire, marker
1/8 in3.18 mm1.57 mm0.51 mmSingle 1 mm wire
3/16 in4.75 mm2.36 mm0.51 mmTwo wire splice
1/4 in6.35 mm3.18 mm0.64 mmThree wire splice
3/8 in9.53 mm4.75 mm0.64 mmSmall connector backshell
1/2 in12.70 mm6.35 mm0.64 mmCable jacket repair
3/4 in19.05 mm9.53 mm0.76 mmHarness branch
1 in25.40 mm12.70 mm0.89 mmBundle cover

Adhesive Lined 3:1 Tubing for Sealed Joints

The 3:1 range is used where the joint has to be sealed as well as covered. Recovered diameter and total wall are given per size, and the meltable inner wall is the layer that fills the gap around the splice.

Ordering SizeExpanded IDRecovered IDTotal WallMeltable Wall
1/8 in3.18 mm1.02 mm1.02 mm0.51 mm
3/16 in4.75 mm1.57 mm1.02 mm0.51 mm
1/4 in6.35 mm2.03 mm1.02 mm0.51 mm
3/8 in9.53 mm3.05 mm1.40 mm0.62 mm
1/2 in12.70 mm4.06 mm1.78 mm0.76 mm
3/4 in19.05 mm6.35 mm2.16 mm0.89 mm
1 in25.40 mm8.13 mm2.54 mm1.02 mm
1-1/2 in38.10 mm12.95 mm2.54 mm1.02 mm

Key Features

Recovered diameter per size – Every size is listed with its recovered diameter, because that is the figure that decides whether the sleeve grips the joint.

Wall stated separately – 0.51 mm and 0.64 mm walls are typical on the 2:1 range, so a larger size is not assumed to give more abrasion protection.

2:1 and 3:1 on one page – A connector backshell and a splice that has to be sealed are chosen from the same table without changing maker.

Shrink temperature stated – 100 C minimum for the 2:1 part, which is what a heat gun has to reach at the sleeve rather than at the nozzle.

UL and CSA listed – 600 V UL recognition and CSA certification are quoted per product, because a harness that goes into a mains product needs both.

Adhesive lined option – The 3:1 part has a meltable inner wall that fills the gap, which is what stops a capillary path under the sleeve.

Applications

These parts are used on harnesses where a joint has to be insulated, strain relieved or sealed against moisture.

Cable splice insulation – A 3/16 in sleeve recovers from 4.75 mm to 2.36 mm with a 0.51 mm wall, which covers a two wire splice and holds it straight.

Connector backshells – A 3/8 in sleeve over a 9.5 mm backshell recovers to 4.75 mm and grips the cable jacket behind the shell, so the bend is taken by the sleeve.

Sealed repairs – A 1/2 in adhesive lined sleeve recovers from 12.7 mm to 4.06 mm and fills the gap with a 0.76 mm meltable wall, which seals a repair that sees moisture.

A sleeve is chosen against the joint, so the recovered diameter is checked against the SUPERB PCB connector height before the harness drawing is released. On the SUPERB PCBA route the tubing is shrunk after the connector is soldered and cleaned, because a sleeve put on before cleaning traps the flux under it.

Sourcing and Cross-Reference

Tubing is bought by ratio and by recovered diameter. The expanded size is what has to pass over the connector, and the recovered size is what has to grip the joint, and a part is only right when both fit. When a sleeve is replaced on a harness that is already in production, the outside diameter of the splice and the length of the overlap are the two figures to send.

The second point is the wall. A 12.7 mm sleeve and a 6.35 mm sleeve both have a 0.64 mm wall, so moving up a size does not add abrasion protection, it only adds clearance. Where the harness runs against an edge, the answer is a heavier wall part or a braided sleeve over the tubing, not a larger shrink size. Where the joint has to be sealed, the adhesive lined part is the only one of the two that fills the gap.

The third point is the shrink itself. The sleeve is cut with an overlap of at least one recovered diameter on each side, shrunk from the middle outwards, and left to cool before it is bent. A sleeve that is stretched while hot recovers thinner than its data sheet says, and a sleeve shrunk from one end traps air at the other. We quote the tubing with the recovered diameter and the wall, because those are the two figures the harness drawing needs.

SUPERB Assembly shrinks the first harness at the quoted temperature and cuts a sample open, because a sleeve that looks tight on the outside can still have a void over the splice.

Q: Can you supply 3:1 adhesive lined tubing that recovers from 12.7 mm to 4 mm for a sealed splice, and confirm the wall and the shrink temperature?

A: Send the outside diameter of the part to be covered, the length, and whether the joint has to be sealed. The SUPERB Tech desk quotes the size by expanded diameter, because a 6.35 mm sleeve on an 8 mm splice does not recover far enough to grip.

Why Buy Heat Shrink Tubing Through SUPERB

  1. Recovered diameter on the quote: Sizes are quoted by expanded and recovered diameter together, because the expanded size alone does not say whether the sleeve will grip.
  2. Wall stated per size: The wall is given for every size, so a larger sleeve is not ordered expecting more abrasion protection.
  3. Sealed and unsealed options: 2:1 and 3:1 adhesive lined parts are on one page, so a splice and a backshell are chosen from the same range.
  4. UL and CSA figures: The 600 V rating and the file numbers are on the page, which is what a mains product harness needs at drawing review.
  5. Checked on the first harness: The first assembly is shrunk at the quoted temperature and cut open, because a sleeve that looks tight can still have a void.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Cable Clamps and Harness Ties for Internal Wiring, Braided Sleeving and Expandable Sleeves for Harness Protection, Cable Markers and Wire Labels for Harness Identification, Cable Glands and Strain Relief Bushings for Enclosure Entries, Wire Ferrules and Crimp Sleeves for Terminal Blocks, How to Verify a Drop in Replacement.