Nylon Grommets and Hole Plugs for Panel Openings
Product Specifications
Product Overview
A hole in a sheet metal panel has two edges and no give. Every cable that moves through it is being rubbed against a 90 degree corner, and every unused hole is a path for dust and a place for a finger. A nylon bushing turns the corner into a radius. A nylon plug closes the hole. Both parts are moulded, both are pushed in by hand, and both are chosen by three numbers: the hole, the panel thickness and the cable or hose that has to pass.
The snap bushings on this page are the Heyco 2000, 2010, 2020, 2030, 2043, 2053, 2075, 2090, 2103 and 2110 series, in black or white nylon 6/6. They lock with fingers that snap into the hole under fingertip pressure, and the number of locking steps sets the panel range: a single step part takes up to 1.0 mm or 1.6 mm, a multiple step part takes up to 3.2 mm and locks at fractional depths in between. The push back force is 35 lb, which is the figure that matters when a cable is pulled hard from the far side of the panel.
The inside diameter is the second figure and the one that gets confused with the hole. A bushing in a 12.7 mm hole can have a 6.4 mm, 7.9 mm or 9.9 mm inside diameter, and the right one depends on the cable bundle rather than on the panel. The 2053 part with a 9.9 mm inside diameter in a 12.7 mm hole leaves a 1.4 mm wall, which is what protects a bundle of four 4 mm cables. The 2058 part in the same hole has a 6.4 mm inside diameter and a thicker wall, which is the right choice for a single 5 mm cable that is pulled through at an angle.
The dome plugs close the holes that are not used. They are moulded in heat stabilised nylon 6/6 in black, rated from -40 to 105 C, and in standard nylon 6/6 in white, rated from -40 to 85 C. The head is a convex matte dome about 1.6 mm thick, which sits almost flush and does not catch on a sleeve. The locking fingers work in the same fractional steps as the bushings, so a plug in a 12.7 mm hole takes panels up to 3.2 mm and holds at 1.6 mm without rattling.
The colour is not cosmetic. Black heat stabilised nylon is the part to use where the panel runs warm, because the stabiliser is what keeps the part from going brittle after a few hundred hours at 90 C. White nylon 6/6 is cheaper and fine on a cool panel, but its rating stops at 85 C. Both are 94V-2, so neither is the part to fit inside a sealed box that has to meet a V-0 requirement.
The practical rules are short. The hole has to be deburred before the part goes in, because a burr under the flange is what makes a bushing sit proud. The panel thickness has to be measured at the hole rather than on the drawing, because a formed panel is thinner at a corner. And the part is fitted before the cable is terminated, not after, because a bushing that is cut to slip over a finished connector is a bushing that no longer closes.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Bushing hole range | 6.4 mm to 22.2 mm | Snap bushings |
| Bushing inside diameter | 3.2 mm to 15.9 mm | Snap bushings |
| Bushing panel thickness | Up to 1.0 mm, 1.6 mm or 3.2 mm | By locking step |
| Bushing material | Nylon 6/6 | All bushings |
| Bushing flammability | 94V-2 | All bushings |
| Bushing temperature | -18 C to 105 C | All bushings |
| Bushing push back | 35 lb | All bushings |
| Bushing approvals | UL file E15331, CSA file 8919 | All bushings |
| Plug hole range | 4.7 mm to 50.8 mm | Dome plugs |
| Plug head thickness | About 1.6 mm | Dome plugs |
| Plug panel thickness | Up to 1.6 mm, 3.2 mm or 6.4 mm | By part |
| Plug material and temperature | Heat stabilised nylon 6/6, -40 to 105 C, or white nylon 6/6, -40 to 85 C | By colour |
| Plug approvals | UL file E51579, CSA file 8919 | Dome plugs |
Included Models and Order Codes
The rows below are the bushings we quote most often, in black with the white part number alongside. Hole, inside diameter and panel thickness are given per part because a 12.7 mm hole takes several bushings and only one of them has the wall the cable needs.
| Part Number Black | Part Number White | Hole Diameter | Inside Diameter | Head Diameter | Panel Thickness |
|---|---|---|---|---|---|
| 2003 | 2004 | 6.4 mm | 3.2 mm | 7.9 mm | Up to 1.0 mm |
| 2000 | 2001 | 6.4 mm | 3.6 mm | 7.9 mm | Up to 1.6 mm |
| 2010 | 2011 | 7.9 mm | 4.8 mm | 9.5 mm | Up to 1.6 mm |
| 2020 | 2021 | 9.5 mm | 4.8 mm | 11.9 mm | Up to 3.2 mm |
| 2030 | 2031 | 9.5 mm | 6.4 mm | 11.9 mm | Up to 3.2 mm |
| 2043 | 2044 | 11.1 mm | 7.9 mm | 13.5 mm | Up to 3.2 mm |
| 2053 | 2054 | 12.7 mm | 9.9 mm | 14.5 mm | Up to 3.2 mm |
| 2090 | 2091 | 19.1 mm | 9.9 mm | 21.6 mm | Up to 3.2 mm |
| 2103 | 2104 | 20.6 mm | 15.9 mm | 22.6 mm | Up to 3.2 mm |
| 2110 | 2111 | 22.2 mm | 9.5 mm | 24.2 mm | Up to 3.2 mm |
Dome Plugs for Unused Panel Holes
Dome plugs are quoted by hole and by panel thickness. The head is a convex matte dome about 1.6 mm thick, so the part sits close to flush and does not catch on a sleeve or a door seal.
| Part Number Black | Part Number White | Hole Diameter | Head Diameter | Overall Height | Panel Thickness |
|---|---|---|---|---|---|
| 2590 | 2591 | 4.7 mm | 6.4 mm | 5.9 mm | Up to 1.6 mm |
| 2603 | 2604 | 6.4 mm | 7.9 mm | 7.9 mm | Up to 1.6 mm |
| 2613 | 2614 | 7.9 mm | 9.5 mm | 9.5 mm | Up to 1.6 mm |
| 2617 | 2618 | 9.5 mm | 11.9 mm | 10.3 mm | Up to 3.2 mm |
| 2643 | 2644 | 12.7 mm | 14.2 mm | - | Up to 3.2 mm |
| 2683 | 2684 | 19.1 mm | 23.1 mm | - | Up to 3.2 mm |
| 2703 | 2704 | 22.2 mm | 25.8 mm | 11.5 mm | Up to 3.2 mm |
| 2713 | 2714 | 25.4 mm | 30.6 mm | - | Up to 3.2 mm |
| 2740 | 2741 | 31.7 mm | 34.9 mm | - | Up to 3.2 mm |
| 2783 | 2784 | 50.8 mm | 55.1 mm | - | Up to 6.4 mm |
Key Features
Hole and inside diameter both stated – A 12.7 mm bushing is listed with 6.4 mm, 7.9 mm and 9.9 mm inside diameters, because the cable decides which one is right.
Panel range per locking step – Single step parts take 1.0 mm or 1.6 mm panels and multiple step parts take 3.2 mm, with fractional locking in between.
Push back of 35 lb – The holding force is quoted, which is what matters when a harness is pulled from the far side of a panel.
Black and white part numbers together – Both colour codes are given in one row, so a black part is not ordered as the white equivalent by mistake.
Temperature graded by colour – Black heat stabilised nylon is rated to 105 C and white to 85 C, so a warm panel does not get the cheaper part.
Plugs to close the spare holes – Dome plugs from 4.7 mm to 50.8 mm close the holes that no cable uses, in the same nylon and the same locking style.
Applications
These parts are used on any panel where a cable passes through sheet metal or where a hole has to be closed after a change.
Instrument side panels – A 12.7 mm bushing with a 9.9 mm inside diameter carries a four cable bundle through a 1.6 mm panel without the edge cutting the jacket.
Outdoor and washdown cases – A 22.2 mm bushing in a 3.2 mm panel takes a hose run, and the dome plugs close the conduit holes that are no longer used.
Rack and cabinet blanks – A 25.4 mm dome plug closes a knockout left by a removed connector, with a head that sits close to flush under the door seal.
A hole edge is decided at the panel cut, so the bushing is checked against the SUPERB PCB outline and the cable route before the sheet is punched. On the SUPERB PCBA route the bushings and plugs are fitted after the harness is dressed, because a plug pressed in before the last cable is pulled is a plug that comes out again.
Sourcing and Cross-Reference
A bushing is bought by hole, and it is rejected by panel thickness. The same 12.7 mm part fits a 1.0 mm panel and a 3.2 mm panel only if it has multiple locking steps, and the single step version will sit loose on the thicker panel. When a part is replaced on a panel that is already punched, the hole, the panel thickness at the hole and the cable outside diameter are the three figures to send.
The second point is temperature. A black heat stabilised bushing is rated to 105 C and a white standard part to 85 C, and the difference only shows up after a few hundred hours. On a panel next to a power supply or a heatsink the black part is the one to specify, and the extra cost is small against a field return. Neither colour is V-0, so a sealed box that has to meet a flame requirement needs a different part.
The third point is fitting. The hole is deburred, the part is pressed in by hand until the flange seats, and the cable is pulled through before it is terminated. A bushing cut to slip over a finished connector no longer closes around the cable, which defeats the purpose. The plugs are fitted the same way, and a plug that is pressed in with a tool rather than a thumb is usually a plug that is one size too large for the hole.
SUPERB Assembly presses the first bushing by hand and pulls a spare cable through it at the working temperature, because a nylon part that fits cold and cracks at 90 C is a part that fails in the field rather than on the bench.
Q: Can you supply a 12.7 mm nylon bushing for a 2 mm panel with a 9.9 mm inside diameter, plus dome plugs for the spare 25.4 mm holes in the same panel?
A: Send the hole diameter, the panel thickness and the cable or hose outside diameter. The SUPERB Tech desk quotes the bushing with its inside diameter and its maximum panel thickness, because a 12.7 mm hole takes three different bushings and only one of them fits a 2 mm panel.
Why Buy Nylon Grommets and Hole Plugs Through SUPERB
- Hole, inside diameter and panel together: All three figures are quoted per part, which is where a 12.7 mm bushing gets ordered for a 3.2 mm panel with a single locking step.
- Temperature graded by colour: Black parts are rated to 105 C and white to 85 C, so a warm panel is not fitted with the cheaper moulding.
- Bushings and plugs in one order: The parts that protect a cable and the parts that close a spare hole ship together, in the same nylon and the same locking style.
- Holding force stated: The 35 lb push back figure is on the page, because a bushing that pulls out under harness tension is a warranty claim.
- Fitted before termination: The first unit is dressed and pulled at working temperature, because a part that fits cold is not proof that it fits hot.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Cable Glands and Strain Relief Bushings for Enclosure Entries, Breather Vents and Pressure Equalization Plugs for Sealed Cases, Cable Clamps and Harness Ties for Internal Wiring, Rubber Bumpers and Feet for Enclosure Support, Fan Guards and Filter Screens for Enclosure Cooling, How to Verify a Drop in Replacement.