TPS24701DGKR
Product Specifications
TPS24701DGKR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS24701DGKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS24701DGKR 2.5 V to 18 V hot swap controller with automatic retry after a fault
The TPS24701 is the same controller as the TPS24700 with one difference that changes how a product behaves in the field: when the fault timer expires it starts a restart cycle instead of staying off. That makes it the right part for equipment that nobody visits, where a transient has to be ridden out and the rail has to come back on its own. It drives an external N channel MOSFET and works on rails from 2.5 V to 18 V.
The protection scheme is unchanged. A 25 mV sense threshold sets the current limit, a 60 mV threshold sets the fast trip, a capacitor on TIMER sets the fault time, and the gate is pulled down inside 8 to 18 microseconds when the fast trip comparator acts. The retry duty cycle is set by the timer components, and the document describes the restart sequence in the circuit breaker section.
Key parameters taken from the TPS24701DGKR document
| Input range | 2.5 V to 18 V recommended operating on the sense and supply pins |
| Current limit threshold | 25 mV typical with a 22.5 to 27.5 mV window, which is 12.5 A on a 2 mOhm sense resistor |
| Fast trip threshold | 60 mV typical with a 52 to 68 mV window |
| Fast turn off | 8 to 18 microsecond from the comparator crossing to the gate being down |
| Fast turn off delay | 200 ns from an 80 mV step across the sense element |
| Retry | Automatic restart after the fault timer expires, with the duty cycle set by the timer components |
| Supply current | 1.4 mA maximum with the part enabled |
| UVLO | 2.32 V rising, 2.22 V falling, 0.1 V of hysteresis |
| Enable threshold | 1.3 V typical falling |
| Fault timer | Capacitor on TIMER, lower threshold 0.35 V, with a bleed down resistance between events |
| Over temperature | 140 C rising with 10 C of hysteresis |
| Power good | Open drain PGb output |
| Package | VSSOP DGK, 8 pins, 2500 pieces on a large reel and 80 pieces in a tube |
| Moisture and temperature | Level 1 at 260 C with unlimited floor life, minus 40 to 85 C |
| Addendum status | TPS24701DGKR and TPS24701DGK are Active and in Production, and the reel row carries marking 24701 |
Every row above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for a first article.
Where the numbers matter in a real build
The retry cycle is a budget decision as much as a part choice. A load that faults, cools and retries on a fixed duty cycle will keep the upstream supply loaded for the fraction of time the timer allows, and if that fraction is too large the upstream supply never recovers its own margin. The document describes the timer charging and the restart sequence, and the practical rule is to set the fault time long enough that the retry looks like a periodic pulse to the upstream converter rather than a continuous load.
The same two thresholds that make the latch part predictable make the retry part safe. A short crosses 60 mV and the gate is off in microseconds, so the retry energy is delivered into a fault for a very short time on each attempt. An overload that sits between 25 mV and 60 mV is where the energy goes, because the part regulates the current for the whole fault time, and that is the case that heats the MOSFET and needs a safe operating area check.
The sense resistor tolerance is worth more attention on a retry part than on a latch part. Every retry pushes current through the same element, so a resistor that drifts with temperature moves the limit on every attempt. A 1 percent low inductance part with a low temperature coefficient keeps the limit stable, and the 25 mV threshold means the resistor value is small, which is why the routing of the sense traces matters as much as the resistor itself.
Auto retry does not remove the need for a fault flag. The PGb output tells the system that the rail is not ready, and a controller that logs that signal can count the retries and decide to shut the slot down after a number of attempts. That combination, a retrying hot swap controller plus a system controller that counts the retries, is what gives a product both the self healing behaviour and the protection against a permanent fault.
The 18 V upper end of the range is the constraint that sends 24 V and 48 V products to a different part. The absolute maximum is only a little above the recommended maximum, so a 12 V rail with a wide tolerance, a battery rail that can reach 16.8 V, and a 15 V rail with a transient are all inside the range, while a 24 V industrial rail is not.
- Retry duty cycle against the upstream supply, since a retry that is too frequent never lets the supply recover.
- Sense resistor tolerance and temperature coefficient, because every retry uses the same element.
- Fault timer against the thermal time constant of the external MOSFET, not against the load capacitance alone.
- Safe operating area of the MOSFET at the current limit for the full fault time.
- Fault flag wiring so the system can count retries and give up on a permanent fault.
- Enable pin state during power up and during a system reset, since a floating pin is undefined.
Which projects this part fits
This part fits equipment that has to come back without a visit: remote radio units, outdoor cabinets, pole mounted cameras, industrial gateways, vending and ticketing machines, and any product with a pluggable module that a field technician inserts by hand and may not seat cleanly on the first attempt. It also fits the second source case for the LTC4211, on the same board, with only external component changes.
Questions that come up before a purchase order is released
How does the retry differ from the latch member?
On this part the fault timer expiry starts a restart cycle, so the rail comes back by itself. On the latch member the MOSFET stays off until the enable pin is cycled. The electrical limits are the same, which is why the two are easy to confuse in a bill of materials.
How is the retry duty cycle set?
By the timer components. The document describes the charging current into the TIMER capacitor and the lower threshold at which the timer resets, and the ratio between the two is what sets the fraction of time the part spends trying.
Can a permanent short damage the part?
The fast trip path keeps each attempt short and the timer keeps the average power low. The part is built to retry into a fault, but the external MOSFET still has to be chosen for the pulse energy, and the upstream supply has to be able to deliver the current for the short window.
What is the maximum rail voltage?
18 V recommended operating. A 24 V rail needs the higher voltage member of the family, and a 48 V telecom rail needs the power limiting controller with a 80 V rating.
Does the part need an external sense resistor?
Yes. The sense element is external on this controller, which is how the current rating is chosen by the board rather than by the package. The 25 mV threshold means the resistor is small and the sense traces have to be Kelvin connected.
What is the marking on the reel?
The addendum prints marking 24701 on the TPS24701DGKR rows and 24700 on the tube rows of the sibling part, so a marking check has to be matched to the orderable string and the carrier.
How SUPERB handles this line
We supply the TPS24701DGKR on original 2500 piece reels and as 80 piece tubes, with the date code and marking recorded. The power management cross reference page lists the controllers we carry by rail voltage and current class, pin to pin cross reference covers the second source case for the LTC4211, and BOM shortage recovery is how we handle a line that is short of one value in the middle of a build.