DRV8844PWPR
Product Specifications
DRV8844PWPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV8844PWPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV8844PWPR: Four Half Bridges on One Die for Two Motors, One Stepper or Four Solenoids
DRV8844PWPR is a quad half bridge driver with individual channel control in a HTSSOP (PWP) body of 28 pins. It provides four independently controlled half bridges rated 2.5 A peak and 1.75 A RMS per bridge at 24 V and 25 C, running from 8 V to 60 V, with a 3.3 V 10 mA regulator on board and a logic ground that floats so the part can sit between split supplies up to plus or minus 30 V.
Order code and package
| Ordering string | DRV8844PWPR |
| Family | DRV8844 quad half bridge, document SLVSBA2E revised July 2025 |
| Package | HTSSOP with thermal pad, PWP body, 28 pins, 9.70 mm by 6.40 mm nominal |
| Reel and packing | 2000 pieces on a large reel, NiPdAu lead finish |
| Moisture level | Level 3, 260 C peak, 168 hour floor life |
| Part marking | DRV8844 |
| Tube row | DRV8844PWP is printed Obsolete, so the R string is the only active packing |
| Operating supply | 8 V to 60 V on the motor supply, with a 3.3 V 10 mA auxiliary regulator |
| Output rating | 2.5 A peak and 1.75 A RMS per bridge at 24 V and 25 C with adequate copper |
| Logic interface | One input per half bridge plus a reset and a sleep pin, all with internal pulldowns |
| Floating logic ground | Inputs and the fault output reference a separate ground pin for split supply work |
Electrical parameters that decide the application
| High side on resistance | 0.24 ohm typical at 25 C and 0.29 ohm at 85 C, at 24 V and 1 A |
| Low side on resistance | 0.24 ohm typical at 25 C and 0.29 ohm at 85 C, at 24 V and 1 A |
| Overcurrent trip | 2 A typical, with a deglitch time before the channel latches off |
| Under voltage lockout | 6.3 V minimum and 8 V maximum on the rising supply |
| Supply current | 5 mA typical with the bridges idle, 500 to 800 microamps in sleep |
| Auxiliary regulator | 3.18 V to 3.52 V at up to 10 mA, and it stays alive in sleep mode |
| Logic thresholds | Input high from 2.2 V above the logic ground, input low below 0.6 V |
| Internal pulldowns | About 100 k on every input, the reset and the sleep pin |
| Wake time | About 1 ms from sleep to full operation |
| Dead time | Inserted internally between the high and low side of each half bridge |
| Parallel operation | Outputs can be tied to double the current in one load |
| Thermal path | The PowerPAD has to be soldered to a copper area, the current figures assume it |
Family variants and how they differ
| DRV8844PWPRG4 | The same reel under the green material row, identical die and packing |
| DRV8313 | Three half bridges at the same 2.5 A and the same voltage class, with a comparator on board |
| DRV8412 | Two full bridges at 3 A continuous for a motor that needs more current per winding |
| DRV8803 | Four low side switches when the load is a relay, a solenoid or a unipolar stepper |
| DRV8825 | A stepper driver with the indexer built in when the controller should not generate the sequence |
| DRV8841 | A dual full bridge in the same family for a two motor load that does not need four independent halves |
Points to check before this part goes on a BOM
The current rating depends on copper, and the reel label does not say so. 2.5 A peak and 1.75 A RMS per bridge are quoted at 24 V and 25 C with proper heatsinking, which on this body means a thermal pad soldered to a copper area with vias under it. A board that pours the pad onto a single layer will reach thermal shutdown well below those numbers.
On resistance is quoted at 1 A, not at the rated current. At 0.24 ohm and 1.75 A the conduction loss is about 0.74 W per bridge in the high side device alone, and with four bridges running the package dissipation passes 3 W before switching losses, which is why the thermal pad in the next note matters more than the headline current.
The overcurrent trip is fixed at 2 A typical and it latches. When a channel trips, the part turns that channel off and holds it off until the reset pin is pulsed or the motor supply is cycled. A system that expects a retry has to drive the reset itself, because there is no automatic recovery in this part.
The logic ground can float, which is the feature that lets the part drive a load referenced to a negative rail. The inputs then have to be driven relative to that floating ground rather than to the controller ground, and an optocoupler or an isolator is normally needed. Boards that tie the logic ground to the controller ground lose that capability and should not assume the split supply arrangement still works.
The auxiliary 3.3 V regulator stays alive in sleep mode. That is useful for keeping a small logic section powered, and it also means the sleep current of 500 to 800 microamps is not zero, which matters on a battery product that relies on the driver being fully off.
Two motors, one stepper or four solenoids on the same part
Each half bridge has its own input, so the same package serves three different load types without a change. Two brushed motors use two half bridges each and the direction comes from which of the two is driven, a bipolar stepper uses all four in a bridge arrangement, and four solenoids use one half bridge each with the other end tied to ground or to the supply.
The parallel option is what covers a load slightly above the per bridge rating. Two half bridges tied in parallel give twice the current with the same on resistance path, at the cost of losing independent control of those two channels. That is the usual answer when a single motor needs 3 A and the board already carries this part for a second axis.
What a 60 V rating buys in a 48 V system
A 48 V rail with a regenerative load does not stay at 48 V. A motor that is decelerating pushes the rail up until a brake resistor or a clamp catches it, and a driver rated at 60 V has room for that excursion where a 40 V part does not. The absolute maximum is above the operating range, and the operating range is what the 8 V to 60 V figure describes.
The undervoltage lockout at 6.3 V to 8 V is the other end of the same story. A 12 V rail that sags during a start transient drops towards 8 V, and below the lockout the part turns all outputs off and reports a fault rather than driving the load with a weak gate. That behaviour is safer than it sounds but it does end the motion, so a supply with a soft start has to be checked against it.
Where this order code fits
The part is used where one package has to drive two small brushed motors, a bipolar stepper or a bank of solenoids from a 12 V to 48 V rail, and each channel has to be switched on its own. Teams comparing it with a neighbouring part start from our Pin to Pin Cross Reference page, and teams replacing a part that has gone end of life start from the Power Management Cross Reference page.
Questions buyers ask
How much current can all four bridges carry at once? The per bridge figure is 1.75 A RMS at 24 V and 25 C with the thermal pad soldered to copper. With all four running the package dissipation is roughly four times the single bridge figure, so the practical simultaneous current is set by the thermal resistance of the board rather than by the silicon. Measure the case temperature on the first prototype.
Does a fault clear itself? No. An overcurrent event latches the affected channel off until the reset pin is pulsed or the motor supply is cycled. Over temperature and undervoltage behave differently, and the fault pin reports all three conditions on one open drain output, so the controller has to distinguish them by other means.
Is there any difference between the R and the tube string? Only the packing. The tube row is printed Obsolete while the R row is active at 2000 pieces on a large reel, and the G4 row is the same reel under the green material heading. For a repair lot, a broken reel is the usual source rather than the tube row.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the OEM Procurement page sets out the checks that keep a substitute from failing on the bench.