DRV8434PWPR
Product Specifications
DRV8434PWPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV8434PWPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV8434PWPR: Microstepping Stepper Driver With Integrated Current Sense
DRV8434PWPR is a microstepping stepper motor driver with the current sense built into the bridge in a 28-pin HTSSOP body of 28 pins. The part runs from 4.5 V to 48 V, holds 2.5 A full scale and 1.8 A rms, and removes the two sense resistors a discrete bridge needs, at the cost of the accuracy those resistors would have set by their own tolerance.
Order code and package
| Ordering string | DRV8434PWPR, HTSSOP-28 (PWP), 9.7 mm by 4.4 mm, PowerPAD down |
| Second package | DRV8434RGER, VQFN-24 (RGE), 4.0 mm by 4.0 mm, exposed pad |
| Supply | VM 4.5 V to 48 V, internal 5 V regulator for logic and charge pump |
| Output | 2.5 A full scale, 1.8 A rms, set by the TRQ setting and not by a resistor |
| Logic | 1.8 V, 3.3 V and 5 V inputs, STEP and DIR plus tri-level and quad-level pins |
| Temperature | -40 C to +125 C ambient, 150 C junction |
Electrical parameters that decide the application
| RDS(on), high side | 200 mOhm typ at 24 V and 25 C, 300 mOhm max at 150 C |
| RDS(on), low side | 280 mOhm typ at 25 C, 350 mOhm max at 150 C |
| Full scale accuracy | plus or minus 4 percent of 2.5 A |
| VM current, enabled | 5 mA typ, 6.5 mA max, no motor load |
| Sleep current | 2 uA typ, 4 uA max, nSLEEP low |
| Wake time | 0.8 ms to 1.2 ms from nSLEEP high to output |
| Charge pump | VM plus 5 V, switching at 360 kHz |
| STEP input | up to 500 kHz applied, bandwidth limited by the motor |
| Off times | 7 us, 16 us, 24 us and 32 us on the TOFF pin |
| Thermal resistance | 29.7 C/W to 39.0 C/W junction to ambient, HTSSOP |
Points to check before this part goes on a BOM
The 4 percent figure is a fraction of 2.5 A, which is 100 mA, and it is the whole error budget: a motor rated 2.0 A cannot be run at the 2.5 A setting because the plus 4 percent corner puts the winding at 2.6 A, 30 percent over its rating, so the useful ceiling here is about 1.9 A of programmed current and the rest of the range is thermal headroom for short moves.
Conduction loss follows the two FETs in series, not the current rating: 330 mOhm at 1.8 A rms is 1.07 W, and at the 39 C/W corner of the HTSSOP that is a 42 C rise inside the package before the board copper helps. The 48 V rating does not change the number, because loss follows current and resistance only, so a 48 V stage and a 12 V stage with the same motor run equally hot.
At the bottom of the supply range the part is not the same part: the internal regulator falls to 4.2 V at a 4.5 V input, the charge pump is then only 5 V above VM, and the high side FET sees the 4.2 V minus a diode drop of gate drive rather than the nominal figure, so a 5 V motor supply sits on the corner of the tables and needs the thermal margin recalculated.
Sleep current of 2 uA is 17.5 mAh over a year while the enabled part at 5 mA is 43.8 Ah, a factor of 2500, so nSLEEP has to be driven by the controller and never tied high. The wake time of 1.2 ms is the price, and a stage that wakes for every 5 ms move spends a fifth of its time waking.
At 1/256 microstepping the 500 kHz STEP limit becomes 1953 full steps a second, which is 9.8 revolutions a second on a 1.8 degree motor, so the indexer is not the limit in a printer or an inspection stage; the motor, its supply and the decay setting are.
Open load detection looks for the current signature of a missing winding, so it only reports a fault while the motor is stepping. A stage that holds position with the bridge off shows a clean status with the connector unplugged, and the first indication is a move that does not happen. Spread spectrum clocking moves the bridge frequency by a few percent, which spreads the emission peak enough to pass a radiated limit without a shield, at the cost of a small current ripple that the decay setting has to absorb.
The off time is the knob that most boards get wrong first: 16 us against a 2 mH winding at 24 V gives 192 mA of ripple, 10 percent of a 2 A setting, while 32 us doubles it to 384 mA and takes a low inductance motor into discontinuous current on every step. Discontinuous current is not a fault, but it is audible as a tick and it changes the torque at low speed, which is why 7 us and 16 us are the settings used in quiet equipment.
Where this order code fits
Printers, cash handling machines, textile equipment, stage lighting and 3D printers use this part where two sense resistors and their Kelvin connections would not fit. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
How is the coil current set with no sense resistor? Through the sense FETs in the bridge and the TRQ setting, with 4 percent accuracy over temperature. No external resistor is needed, and none can be added to tighten it.
Will it drop into a DRV8426 socket? The vendor lists pin compatibility with the DRV8426, the DRV8436 and the DRV8424/25, but the 33 V members and the 900 mOhm members are different silicon with different thermal limits, so the socket saves rework and not re-qualification.
What clears a latched fault? A low pulse on nSLEEP of 20 us to 40 us. The nFAULT pin is open drain and needs a pull up, and the fault type is only visible by reading which protection responded.
Does smart tune change the current waveform? It adjusts the decay automatically to hold regulation as the motor warms, which reduces audible noise, but it also means the current waveform at the same TRQ setting differs from a fixed slow decay setting, so acoustic and torque measurements are not comparable between the two modes.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.