DAC8571IDGKR
Product Specifications
DAC8571IDGKR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DAC8571IDGKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DAC8571IDGKR: the 16-bit converter with an I2C port in an eight pin MSOP
The DAC8571IDGKR is a single channel, 16 bit voltage output converter in an eight pin MSOP, packed 2500 pieces on a large tape and reel. The vendor carries the part as ACTIVE and lists a single supply of 2.7 V to 5.5 V, a two wire I2C interface that supports standard, fast and high speed modes to 3.4 MHz, a settling time of 10 microseconds to 0.003 per cent of full scale, a relative accuracy of 0.098 per cent of full scale, an output range of zero to the reference, and an operating range of minus 40 to plus 105 degrees. Typical power is 800 microwatts at 5 V, falling to about 1 microwatt in power down.
The interface is what makes this part different from the other sixteen bit converters in the same catalogue. A two wire port means two pins and a shared bus, so four of these converters can sit behind one controller without four chip selects, and the part can be read back, which the serial parts of the same class cannot. The readback is the feature that matters in a system that has to verify the analogue output after a brownout, because it returns the contents of the shift register rather than a status bit.
The DAC8571IDGKR rows as the addendum publishes them
| Part class | Single channel 16 bit voltage output converter |
| Vendor status | ACTIVE, production data |
| Data sheet | SLAS373A, December 2002, revised July 2003 |
| Supply range | 2.7 V to 5.5 V, single supply |
| Resolution | 16 bits |
| Relative accuracy | 0.098 per cent of full scale range |
| Differential nonlinearity | 0.25 LSB typical, 1 LSB maximum, monotonic over temperature |
| Offset error at code 485 | 0.3 mV typical, 1.0 mV maximum at 25 degrees |
| Offset error over temperature | 1.0 mV typical, 5.0 mV maximum |
| Full scale error at code 64714 | 0.5 mV typical, 3.0 mV maximum at 25 degrees |
| Full scale error over temperature | 1.0 mV typical, 5.0 mV maximum |
| Absolute accuracy | 2.5 mV at 25 degrees, 3.5 mV over temperature |
| Zero code drift | minus 20 microvolts per degree |
| Gain temperature coefficient | minus 5 parts per million of full scale per degree |
| Settling time | 8 microseconds typical, 10 maximum, fast settling mode |
| Settling with 500 pF | 12 microseconds |
| Slew rate | 1 volt per microsecond |
| Output range | Zero to the reference voltage |
| Reference input impedance | 140 kilohm |
| Interface | Two wire I2C, standard, fast and high speed to 3.4 MHz |
| Update rate at 400 kHz | 22.22 thousand samples per second |
| Power down modes | High impedance, 1 kilohm to ground, 100 kilohm to ground |
| Body | MSOP, 8 pins, marking D871 |
| Reel row | DAC8571IDGKR, 2500 pieces, large tape and reel |
| Tube row | DAC8571IDGK, 80 pieces, tube |
| Moisture level | Level 2 at 260 degrees, one year floor life |
| Thermal | 260 degrees per watt junction to ambient, 44 junction to case |
The three power down modes are the row that a system engineer reads twice. A high impedance output leaves the node floating, a 1 kilohm output pulls it to ground through a known resistance, and a 100 kilohm output does the same with a smaller load. In a loop that must fail to a defined level when the controller stops talking, the choice between those three is the fail safe behaviour, and it is set by a register rather than by a pin, so it can be changed without a board change.
What the electrical table fixes
The absolute accuracy figure of 2.5 mV at 25 degrees and 3.5 mV over the whole range is the one to use for a control loop, because it is quoted across every code from 485 to 64714 rather than at a single point. On a 2.5 V reference 3.5 mV is 0.14 per cent of full scale, which is about 11 bits of absolute accuracy from a 16 bit converter. The resolution is real, the absolute accuracy is not, and a customer who needs 16 bit absolute accuracy has to calibrate in the end system.
The offset drift is printed as minus 20 microvolts per degree and the gain drift as minus 5 parts per million per degree, both with a sign, which is unusual and useful. Over the 145 degree operating window the offset moves about 2.9 mV and the gain about 725 parts per million, so a converter calibrated at 25 degrees will be outside its 3.5 mV absolute accuracy at both ends of the range. A loop that calibrates at the operating temperature does not have this problem, and a loop that calibrates on the bench does.
The I2C rate and the settling time together set the update rate, and the document gives the arithmetic: at 400 kHz of serial clock the maximum update rate is 22.22 thousand conversions per second, which is far above the 100 conversions per second that the 10 microsecond settling time allows if every conversion is a full scale step. The bus is not the limit on this part. The analogue settling in fast mode and the current in low power mode are the two limits, and they trade against each other.
Where the body fits on a board
The eight pin MSOP takes about 15 square millimetres of board and needs one decoupling capacitor, one reference connection and two bus lines, so the whole converter is smaller than the connector that brings the I2C in. The 260 degree per watt junction to ambient figure is high, and at 800 microwatts the rise is a fraction of a degree, so it only matters if the output is shorted or if the part is run in fast settling mode continuously into a heavy load.
The address pin is the constraint on a multi converter board. One pin gives two addresses, so two of these parts can share a bus without a multiplexer, and a third needs a second bus or a switch. A customer who plans four channels on one bus should count the address pins before the board is drawn, because adding a bus after the fact costs more than choosing a different converter at the start.
What the documents do not publish
The document is from 2003 and it predates the modern arrangement of a data sheet: it has no thermal information table in the current format, no ESD table beyond a warning about limited built in protection, and no typical characteristics for noise. The thermal numbers we quote are from the absolute maximum section and they are impedance figures at a point, not junction to ambient over a board. A customer who needs a thermal model for a simulation will not find one on the product page.
There is no long term drift figure and no life test data. The part has been in the catalogue for more than twenty years and the current document is unchanged since 2003, which is either reassuring or a warning depending on how the vendor treats a mature line. The product page does print the addendum with live rows, so the status is current even though the document is not.
Second source and long term availability
Sixteen bit converters with an I2C port are made by several vendors and the address scheme is standard, but the three power down modes and the readback behaviour are not, so a cross is a software change plus a check of the fail safe state. The ADC DAC cross reference page sets out the comparison we run, and the how to verify a drop in replacement page covers the bench tests.
The single source risk on a part this old is the die, not the package. A vendor that keeps the reel row live is still shipping the die, and the reel row here is 2500 pieces with a tube row at 80. A customer with a long programme should ask for a written statement of availability and a last time buy window rather than read a status column that changes with the vendor catalogue.
What to send with an enquiry
Send the exact string, the body, the quantity and the date you need it. State the reference voltage and its source, because the reference input impedance is 140 kilohms and a divider will not hold it. State whether the part must fail to a defined level on bus loss, since that decides which power down mode is loaded at start up.
If more than one converter shares the bus, say how many, because the address pin gives two. The BOM scrubbing page explains how we reconcile a line like this against the build quantity before a schedule is confirmed.