Contact Us

HXN40052

Brand: Hisiwell
Hisiwell HXN40052 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN40052 — Discrete & Power Semiconductors | Superb Automation

HXN40052

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN40052 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN40052: one hundred and twenty five watts at 4.4 to 5 GHz on a 32 V rail

The HXN40052 is the 51 dBm member of the Hisiwell 4.4 to 5 GHz ladder and the only continuous wave part on the band that runs from 32 V instead of 28 V. The published row reads 4.4 to 5 GHz, saturated output at least 51 dBm, gain at least 10 dB, drain efficiency at least 45 per cent, 32 V, plus or minus 0.8 dB of flatness, continuous wave. Both ports are 50 ohm on a film hybrid carrier.

One hundred and twenty six watts of radio frequency at 45 per cent efficiency draws 279.8 W from the 32 V rail, which is 8.74 A, and leaves 153.9 W of heat. Drive at the 10 dB gain floor is 41 dBm, 12.6 W. The rail step buys 1 dB of output over the 28 V member for 0.8 A more drain current, which is a better trade than raising the current on 28 V would be.

The output voltage into 50 ohm at saturation is 79.3 V RMS and 112.2 V peak. That is a level where the output path stops being a cable and becomes an assembly: a rated connector, a rated load and an isolator, with the measurement taken through a coupler rather than by direct connection.

A separate 32 V feed is the practical cost of this part. A chassis built on 28 V cannot carry it alongside the smaller members without a second converter, and that converter has to deliver 8.74 A with the sequencing and the overshoot behaviour the vendor does not specify.

The parameter rows Hisiwell publishes for HXN40052

Part classGallium nitride power transistor, internally matched
Frequency range4.4 to 5 GHz
Bandwidth, calculated600 MHz, 12.8 per cent fractional at a 4.70 GHz centre
Saturation output power as publishedat least 51 dBm
Saturation output power in watts, calculated125.89 W
Gain as publishedat least 10 dB
Drain efficiency as publishedat least 45 per cent
Drain voltage32 V
Flatness across the bandplus or minus 0.8 dB
Operating modecontinuous wave
Input impedance50 ohm
Output impedance50 ohm
Match technology as described by the vendorin plane matching synthesis, film hybrid integration
Output at 1 dB compressionnot published, the index prints a slash
DC input at saturation, calculated279.8 W
Drain current at saturation, calculated8.74 A at 32 V
Drain current if the same part ran on 28 V, calculated9.99 A, outside the published rail
Dissipation at saturation, calculated153.9 W
Dissipation if efficiency falls to 40 per cent, calculated314.7 W
Drive power for the rated output, calculated41 dBm, 12.59 W
Output per 100 MHz of the band, calculated20.98 W
Load voltage at saturation into 50 ohm, calculated79.3 V RMS, 112.2 V peak
Thermal resistance, junction to casenot published
Package outline and dimensionsnot published in text, one image on the product page
Scattering parametersnot published
Pinch off voltage and gate bias pointnot published
Operating and storage temperaturenot published
Moisture level and floor lifenot published
Orderable addendum and packingnot published
Neighbour on the same band at 50 dBmHXN40051, 28 V rail, 10 dB gain
Neighbour on the same band at 53 dBmHXN40053, 28 V rail, pulsed 100 microseconds at 10 per cent

Why the rail was raised instead of the current

At 51 dBm on 28 V the drain current would be about 10 A, which is a hard number for the feed, the choke and the source return. Raising the rail to 32 V brings the same power at 8.74 A, and the load line matches the higher voltage swing the die can produce. That is why the vendor moved the rail rather than the die for this 1 dB step.

The cost is organisational rather than electrical: a second rail in the chassis, a second converter, a second sequencing scheme and a second set of protection thresholds. Where the product already runs 32 V for other bands the step is free; where it does not, this part is the wrong rung and the 28 V member below it is the right one.

The thermal picture does not improve with the rail. 153.9 W of dissipation is 4 dB more heat than the 28 V member, so the carrier and sink have to be sized for the larger figure regardless of the current.

Thermal reality at one hundred and fifty watts of heat

At 3 C per watt the rise would be 462 C and at 5 C per watt 769 C, so this part only runs at saturation on a carrier well below 1 C per watt with a sink that is measured rather than assumed. In practice that means a copper carrier, a spreader and either forced air or a liquid plate.

At 6 dB backoff the output is 31.6 W and the dissipation, at an assumed 30 per cent, is 73.8 W, which is the operating point most C band link amplifiers actually use. The saturated figure is the rating; the backoff figure is the build.

Because the vendor publishes no junction to case, the thermal answer has to be closed on a measurement. A first article with a thermocouple on the flange and a known sink is the only way to establish the margin, and that measurement belongs in the build record rather than in a meeting note.

The band around it: 28 V, 32 V and pulsed members together

The 4.4 to 5 GHz ladder has seven members and three different supply and mode combinations. 37, 40, 43, 47 and 50 dBm run 28 V continuous wave. This part runs 32 V continuous wave. The 53 dBm member returns to 28 V but is pulsed at 100 microseconds and 10 per cent duty.

That shape is unusual in a single band and it matters for procurement: a customer who specifies the band and the output without the rail can be quoted the wrong part. The rail and the mode have to be on the request before a candidate is chosen.

Our RF power transistor cross reference page orders the checks rail first, mode second, band third and power fourth, which is the order that avoids exactly this mistake.

What to fix before a 32 V build is released

The 32 V rail is not specified for sequencing, overshoot or rise time, so the converter has to be conservative and the drain clamp has to be worked out from a measurement rather than copied. An overshoot on a 32 V rail with this die area is not recoverable.

The bias point is unpublished, and at 8.74 A of drain current the first power up has to be current limited with the gate swept from pinch off. The vendor gives no pinch off voltage, so the sweep starts from a low gate voltage and increases until the target quiescent current appears.

The output needs an isolator and a rated load. At 112 V peak into a matched load the mismatch case is well beyond what a laboratory attenuator will take, and a reflected pulse can destroy the carrier before a fuse or a detector reacts. Our guide to choosing an RF amplifier covers the protection order for a stage at this level.

Questions buyers ask about HXN40052

Can it run on 28 V. The published rail is 32 V and the 51 dBm figure is quoted there. Running it on 28 V would draw about 10 A for the same output, outside the published rail, and it is not a configuration the vendor documents.

Is there a pulsed version at this power. The 53 dBm member is the pulsed one and it returns to 28 V at 100 microseconds and 10 per cent duty. For a pulsed radar at this band that part is the ordinary choice.

Does the extra 1 dB justify the second rail. Only if the chassis already carries 32 V. Otherwise the 50 dBm member on 28 V is the cheaper build and the 1 dB is better found in the antenna.

How is it supplied. Through the RF procurement route, with rail, band, mode and quantity on the request and packing confirmed with the factory before a date is quoted.