HXC50010
Product Specifications
HXC50010
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXC50010 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXC50010: the 1000 W part on a 50 V rail, with 0.2 degrees per watt and a full fixture
The HXC50010 is the largest single device on the HXC50 shelf: 1000 W capable, unmatched, filed for HF and VHF, on a 50 V rail, usable in CW and in pulse. The index row gives it 1000 W, a band below 100 MHz and 80 per cent efficiency. The document behind the page, titled HX5011K00B4, gives the numbers that let a buyer size a heat sink, a rail and an output network, and it measures the part on a 130 to 160 MHz wideband fixture with the device soldered: 900 W at 130 MHz with 18.3 dB and 77 per cent, 1000 W at 145 MHz with 18 dB and 73 per cent, and 1070 W at 160 MHz with 17 dB and 71 per cent.
The document also carries the figure that decides whether this part is buildable at all, 0.2 degrees per watt from junction to case, published with its conditions: 80 degree case, 1000 W CW, 50 V rail, 200 mA of quiescent current. A 0.2 degrees per watt path on a 1000 W part is what turns a 370 W heat load into a 74 degree rise. Without that figure a buyer would be guessing at the single most important number on the page.
The third piece of good news is the transient thermal impedance, 0.04 degrees per watt at a 100 microsecond pulse and 20 per cent duty. That is the figure that matters for a plasma generator, an MRI driver or a laser exciter, where the part runs in bursts and the die survives on thermal mass rather than on steady state conduction. The vendor publishes both the steady and the transient number, which is rare on this shelf and is the reason this row can be specified from the document alone.
The HXC50010 rows as the vendor publishes them
| Part class | LDMOS RF power transistor, unmatched, high power, high ruggedness |
| Output, index row | 1000 W |
| Output in dBm, calculated | 60.00 dBm |
| Output measured at 130 MHz, document | 900 W with 18.3 dB gain and 77 per cent efficiency |
| Output measured at 145 MHz, document | 1000 W with 18 dB gain and 73 per cent efficiency |
| Output measured at 160 MHz, document | 1070 W with 17 dB gain and 71 per cent efficiency |
| Frequency range, index row | Below 100 MHz, with the fixture covering 130 to 160 MHz |
| Drain rail | 50 V nominal, 55 V maximum operating |
| Quiescent current in the fixture | 200 mA |
| Drain to source breakdown, document | 130 V minimum at 18 mA |
| Gate to source maximum, document | minus 7 V to plus 10 V |
| Junction temperature maximum, document | 225 degrees C |
| Case operating temperature, document | 150 degrees C |
| Thermal resistance, junction to case, document | 0.2 degrees C per watt at 80 degree case and 1000 W CW |
| Transient thermal impedance, document | 0.04 degrees C per watt at 150 degree junction, 100 microsecond pulse, 20 per cent duty |
| Gate threshold voltage, document | 2.6 V at 600 microamps, 50 V drain |
| Gate quiescent voltage, document | 3.14 V at 200 mA, 50 V rail |
| Input capacitance, document | 400 pF at 50 V and 1 MHz, measured per side |
| Output capacitance, document | 97 pF at 50 V and 1 MHz, measured per side |
| Feedback capacitance, document | 1.95 pF at 50 V and 1 MHz, measured per side |
| Leakage currents, document | 1 microamp drain at 50 V, 1 microamp gate |
| ESD class, document | Human body model Class 2 |
| Package, document | Earless flanged ceramic, four leads, PKG-B4 |
| Fixture board, document | Rogers RO4350B, 0.762 mm, 1 oz copper |
| Fixture transformers, document | 50 ohm RFSFBU-086-50, 12.5 ohm 4 to 1 and 9 to 1 SFF lines, 16.7 ohm SFF line |
| Fixture bulk capacitance, document | Two 4700 microfarad 63 V electrolytics |
| Document title against catalogue number | HX5011K00B4 against HXC50010, not explained by the vendor |
| Orderable addendum | None published |
| Packing quantity and moisture level | Not published |
What 1000 W on a 50 V rail asks of the supply, the load and the output network
1000 W into 50 ohm is 223.6 V rms and 316.2 V peak. On a 50 V rail that is 6.32 times the supply, which only works because the part is a push pull device in which each side drives half the load line and the output transformer sums the two halves. The 130 V minimum breakdown is what allows each drain to swing past twice the rail at full power, and the four lead ceramic body with the source on the flange is what carries the current.
The current is the constraint that shapes the product. At 73 per cent efficiency the DC input is 1370 W, which is 27.4 A at 50 V; at 60 per cent it is 1667 W and 33.3 A. A 33 A bus on a 0.762 mm board with 1 oz copper is not a trace, it is a bus bar, and the fixture in the document uses two 4700 microfarad electrolytics at the device to hold the rail through the key down step. A buyer who sizes the supply for the average current and not the pulse current will see the rail sag on every burst.
The output side sees 316 V peak at full power, 632 V at a 2 to 1 mismatch and 949 V at 3 to 1. Those are the numbers that decide the capacitor voltage rating, the connector and the transformer insulation. On a 1 kW part the output network is not an accessory, it is half the product, and the failure that ends a build is usually a capacitor chosen for 50 V because the rail is 50 V.
Thermal: 0.2 degrees per watt steady and 0.04 transient
At 73 per cent efficiency the heat is 370 W. With 0.2 degrees per watt the rise is 74 degrees, so at an 85 degree case the junction is at 159 degrees, 66 degrees below the 225 degree limit. Move the case to 100 degrees and the junction is at 174 degrees, still inside the limit but with less room for a hot day or a failed fan. The published condition is an 80 degree case, and an assembly that holds the flange at 80 degrees is the one the vendor measured.
The transient figure changes the argument for a pulsed product. At 0.04 degrees per watt and a 100 microsecond pulse at 20 per cent duty, the junction follows the pulse with a small swing rather than the average, which is why a 1 kW part can be run in a 10 per cent duty plasma application on a heat sink sized for a fraction of the average. The limit is the average over the duty cycle, not the peak, and the vendor publishes both numbers so the arithmetic can be done once.
Two practical points. The flange must be flat and the interface material must be specified by thickness and pressure, because at 370 W a 20 micron error in the interface is worth several degrees. And the thermocouple goes on the flange next to the device, not on the heat sink fin stack, because the 0.2 degrees per watt already accounts for the die to case path and only the case temperature is left to measure.
Drive, gain and the band edge
At 18 dB of gain the drive for 1000 W is 15.85 W, or 42 dBm, and at 17 dB it is 20 W. That is a real driver stage, not a small one, and it is the reason a 1 kW amplifier is usually built as a chain rather than as a single stage. The 400 pF input capacitance per side is the load that driver has to charge, and at 160 MHz that capacitance is a low impedance that the driver must be able to drive without loss of gain.
The measured points run from 900 W at 130 MHz to 1070 W at 160 MHz, a spread of 0.75 dB, with gain falling from 18.3 dB to 17 dB over the same range. So the part delivers more power at the top of the fixture band and needs 1.3 dB more drive there, which is what happens when the input match is set for the low end. A product that must hold a flat output across 130 to 160 MHz needs a driver with 2 dB of gain slope compensation, or an input network tuned at the top of the band.
The 50 V rail is where this part is comfortable and it is also the rail the market supplies. A 50 V bus with 33 A of pulse current is a standard industrial arrangement, and the parts around it, the capacitors, the connectors and the current sense, are all available for that rail. That is the practical reason the 1 kW shelf sits on 50 V rather than on a higher voltage where the current would be smaller.
Where the HXC50010 sits on the shelf
Near it are the 700 W and 850 W parts on a 40 V rail at 915 MHz with 15 and 16 dB, the 500 W part at 433 MHz with 21 dB and 74 per cent, and the 650 W single at 50 V to 500 MHz. In decibels the step from 650 W to 1000 W is 1.87 dB and from 850 W to 1000 W is 0.71 dB, so the top of the shelf is crowded and a requirement can usually be met by two different rows.
Read as a choice, this row is the one for a 1 kW socket on 50 V where a published thermal resistance, a published transient impedance and a published fixture matter more than the last half decibel. A buyer who needs the same power in a narrower band at 915 MHz takes the 850 W part on 40 V and accepts a rail change; a buyer who needs 650 W takes the single at 50 V and keeps the same supply and the same output network family.
Before the purchase order goes out
Two procurement points follow. The document is filed as HX5011K00B4 rather than HXC50010, so the incoming route has to handle two names for one die, which is set out on the incoming inspection plan page. And no orderable addendum is published for this row, so the tray quantity, the moisture level and the marking need written confirmation before a production order. Buyers lining this part up against a competitor's 1 kW LDMOS should work from the RF power transistor cross reference, where rail, package and thermal resistance sit side by side. The sourcing side of a 1 kW bill of materials, including the capacitors and the combiners, is covered on the RF component sourcing page.