HXN40033
Product Specifications
HXN40033
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXN40033 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXN40033: 158.5 W in a hundred microsecond pulse on the 2.7 to 3.7 GHz band
The HXN40033 takes the 2.7 to 3.7 GHz group into pulsed operation and onto a 32 V rail. Saturated output is 52 dBm, which is 158.5 W, gain is 12 dB, drain efficiency is 50 per cent, flatness is plus or minus 0.8 dB across the gigahertz, and the published mode is a 100 microsecond pulse at a 10 per cent duty cycle. It is the largest output on this band before the 50 V members begin.
At 50 per cent the rail supplies 317 W during the pulse, the drain current is 9.91 A at 32 V, and the heat is 158.5 W while the pulse is on. On a 10 per cent duty cycle the average dissipation falls to 15.8 W and the average drain current to 0.99 A, so the cooling is sized against a modest steady load while the supply and the feed see the full 317 W for a tenth of the time.
The drive is 40 dBm, or 10 W, which lines up exactly with the HXN40030 member of the same band. A two stage chain from 0.63 W to 158.5 W built from two parts of this family on two rails, 28 V for the driver and 32 V for the final, is the shape the vendor's own ladder invites.
The 32 V rail is worth flagging. It is above the 28 V members below and below the 50 V members above, so a system that standardises on 28 V cannot simply drop this part in, and a system built around a 32 V bus has to check that the driver stage and the drain supply share a ground and a sequencing scheme.
The parameter rows Hisiwell publishes for HXN40033
| Part class | Gallium nitride power transistor, internally matched |
| Frequency range | 2.7 to 3.7 GHz |
| Bandwidth, calculated | 1000 MHz, 31 per cent fractional |
| Saturation output power as published | at least 52 dBm |
| Saturation output power in watts, calculated | 158.5 W |
| Gain as published | at least 12 dB |
| Drain efficiency as published | at least 50 per cent |
| Drain voltage | 32 V |
| Flatness across the band | plus or minus 0.8 dB |
| Operating mode | pulsed, 100 microsecond width at 10 per cent duty |
| Input impedance | 50 ohm |
| Output impedance | 50 ohm |
| Output at 1 dB compression | not published, the index prints a slash |
| DC input at saturation, calculated | 317.0 W |
| Drain current at saturation, calculated | 9.91 A at 32 V |
| Dissipation during the pulse, calculated | 158.5 W |
| Average dissipation at 10 per cent duty, calculated | 15.8 W |
| Average drain current at 10 per cent duty, calculated | 0.99 A |
| Charge drawn per 100 microsecond pulse, calculated | 0.99 mC |
| Drive power for the rated output, calculated | 40 dBm, 10.0 W |
| Dissipation if efficiency falls to 45 per cent, calculated | 193.8 W |
| Thermal resistance, junction to case | not published |
| Transient thermal impedance | not published |
| Package outline and dimensions | not published in text, one image on the product page |
| Scattering parameters | not published |
| Pinch off voltage and gate bias point | not published on this page |
| Operating and storage temperature | not published |
| Moisture level and floor life | not published |
| Orderable addendum and packing | not published |
| Neighbour below on the same band | HXN40032 at 49 dBm on a 28 V rail, continuous wave |
| Neighbour above, narrower band | HXN40034 at 53 dBm over 2.8 to 3.6 GHz on a 50 V rail |
What a hundred microsecond pulse at ten per cent does to the heat budget
The pulse is short and the duty is low, so the average load is 15.8 W and a modest carrier handles it. What the average hides is the 158.5 W that crosses the die during each 100 microsecond window, and the junction excursion that follows. With no transient thermal impedance published, the excursion cannot be computed, and the difference between a good and a poor die attach at that instant is tens of degrees.
The energy per pulse is 0.0317 J at the rail, because 317 W for 100 microseconds is 31.7 mJ, and the charge drawn is 0.99 mC. A rail allowed to sag 1 V needs about 1 mF close to the device, and the ESR of that bank, of the feed and of the flange is what shows up as a leading edge droop. At 9.91 A of pulse current the droop is small but not negligible on a badly routed feed.
The published condition is 100 microseconds at 10 per cent, which is a 1 kHz repetition rate. A system that keys 1 ms at the same duty cycle is asking the die to hold 158.5 W for ten times as long, and the answer is a measurement rather than an assumption. Radar and datalink waveforms both vary in pulse length, so the waveform has to be agreed before the thermal path is fixed.
Efficiency at 45 per cent raises the pulse heat to 193.8 W and the current to 11.01 A. The efficiency row here is printed without a typical marker, unlike the continuous wave members, so the 50 per cent is read as the published value and a purchase specification that needs a floor should ask for one in writing.
A 32 V rail in a family of 28 V and 50 V members
The rail is the awkward row. Members below run on 28 V and members above on 50 V, so a 32 V part fits a system that has already chosen a 28 to 32 V bus for other reasons: a vehicle bus, a battery stack, a legacy amplifier chassis. Where the system runs on 28 V, the 79.4 W member on the same band is the natural choice and delivers half the output at the same gain floor.
Where the system runs on 50 V, this part still works but wastes the rail headroom and cannot deliver the 199.5 W and 251.2 W of the members above. The ladder is regular enough that the choice is made by the bus, not by the dBm, and that is worth knowing before a build is committed to a supply.
Thirty two volts at 9.91 A also sets the isolation and the clearance of the drain feed, and the bias sequencing has to bring the gate up before the drain at a rail where a mistake destroys a part worth more than the driver behind it.
Where a 158.5 W pulse stage over the octave fits
The fit is a pulsed transmitter over 2.7 to 3.7 GHz: a radar front end, a datalink, an instrumentation transmitter, a satellite S band uplink block at the low end, or a test amplifier for high power component work. The octave band and the 10 per cent duty make one unit usable across several allocations, and the 12 dB gain keeps the driver inside a 10 W part of the same family.
It is a poor fit for continuous wave, where 158.5 W of steady heat would need a cooling stack of a different class, and a poor fit for a long pulse at the same duty, and a poor fit for a 28 V bus that cannot be raised. Our RF power transistor cross reference work prints the rail, the mode and the pulse width against each output on this band so the ladder can be read at a glance, and the one stop RF supply view groups the driver, the capacitors and the flange hardware that a chain like this needs.
Where the application is a defence or radar build, the screening and temperature class questions are set out in our defence grade component supply view, because a part with no published temperature range has to have that range agreed in writing before it goes on a platform.
Questions we answer on HXN40033 before a lot is booked
The first is the waveform. Pulse width, duty cycle and repetition rate decide the thermal path, and none of them can be inferred from the 100 microsecond row.
The second is the rail. A 32 V bus has to be planned for 9.91 A of pulse current with a feed that does not ring, and the sequencing has to be enforced in hardware.
The third is the arriving lot. With no moisture level, no marking code and no orderable addendum, the purchase order names the band, the rail and the pulse condition, and the incoming inspection plan records the flange and the DC behaviour of each lot. The RF procurement process puts the pulse condition and the cooling interface in front of the vendor before the first shipment.