Contact Us

VBI2658

Brand: VBsemi
VBsemi VBI2658 is a discrete semiconductors component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBI2658 — Discrete & Power Semiconductors | Superb Automation

VBI2658

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBI2658 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBI2658: a 60 V P channel in an SOT89

The VBI2658 is a single P channel MOSFET rated at minus 60 V drain to source with a plus or minus 20 V gate window and a threshold of minus 1.7 V. It carries minus 6.5 A and its on resistance is 65 milliohm at a 4.5 V gate and 58 milliohm at 10 V. The die is trench silicon and the body is the SOT89.

A 60 V P channel at 58 milliohm is a load switch, a reverse polarity block, or a high side switch on a 24 V or 48 V rail. The 60 V rating covers a 24 V rail with generous margin and a 48 V rail with none, so in practice this is a 12 V or 24 V part. At 2 A it drops 116 millivolt and dissipates 232 milliwatt, which the SOT89 tab can shed on a normal board.

The negative threshold of 1.7 V is the useful number. It means the part turns on when the gate is pulled 1.7 V below the source, which a 3.3 V logic pin can do on a 3.3 V rail and cannot do directly on a 24 V rail without a divider or a small N channel.

Key data for the VBI2658

ConfigurationSingle P channel
PackageSOT89, three lead surface mount with tab
VDSMinus 60 V
VGSPlus or minus 20 V
VthMinus 1.7 V typical
IDMinus 6.5 A
RDS(on) at 4.5 V65 milliohm
RDS(on) at 10 V58 milliohm
TechnologyTrench
Gate chargeNot published on the catalogue page
Body diodeIntrinsic, cathode at drain, which is the orientation that makes a reverse polarity block work
Thermal pathTab on the drain, soldered to a copper island

The gate sits below the source, and that sets the circuit

On a P channel every gate voltage is measured from the source, and the source is normally at the rail. On a 24 V rail a gate tied to ground is 24 V below the source, which is outside the 20 V window and destroys the gate. The standard circuits are a resistor divider from the rail to the gate with a small N channel pulling the midpoint down, or a zener clamp across the gate and source with a resistor to ground.

The 1.7 V threshold means the part is on as soon as the gate is 1.7 V below the source, which happens quickly as the rail rises. On a hot plug event that is a problem: the gate divider charges with the rail, the part turns on before the load capacitors have charged, and the inrush current is limited only by the channel resistance and the wiring. A soft start circuit, or a resistor in series with the gate, is what keeps the inrush inside the rating.

The gate window of 20 V is measured from the source, so the safe gate range moves with the rail. Any circuit that clamps the gate to ground is only valid while the rail stays under 20 V, which is exactly the case on a 12 V rail and not on a 24 V one.

Six and a half amps in an SOT89

At 3 A the part dissipates 0.52 watt and the tab on a modest island puts the junction about 45 degrees above ambient. At 5 A it is 1.45 watt and the body needs a larger copper area or a lower duty cycle. The 6.5 A rating is a die and bond limit, and the continuous figure is nearer 3 A in still air.

The SOT89 tab is the drain, which on a high side switch is the switched rail. That means the copper under the tab moves with the load, and the island is a noise source as well as a heat path. On a reverse polarity block the tab sits at the battery potential, which is a different set of considerations again.

The body diode direction also decides the behaviour at power off. With the cathode at the drain, the diode conducts from source to drain when the drain is pulled below the source, which is what protects the circuit from a reversed supply before the channel turns on. A substitute with the opposite orientation would not protect anything.

Incoming checks on a small P channel

The parameters that vary most between suppliers on a part like this are the threshold window and the body diode drop, and neither shows up in a simple continuity test. Our incoming inspection plan page covers what is checked at the receiving dock before a reel goes to a line, including the sample plan and the record that is kept.

For a P channel the sign convention is the first thing a receiving test has to encode, because a fixture built for an N channel will read a P channel as a failed part. That is a documentation problem rather than a silicon one, and it is the most common reason a correct shipment is rejected.

The sourcing side of this part is covered on the date code management. For a small P channel that can sit in stores, that page covers how age is tracked and what will not be shipped into a new build.

Questions we get on this code

Can the gate be tied to ground on a 24 V rail? No. That is 24 V below the source and outside the 20 V window. Use a divider or a clamp.

Does it block reverse polarity by itself? The body diode orientation is right for it, but the channel has to be held off and the gate referenced to the source for the block to hold. A single part plus a resistor does the job at low current.

Is 6.5 A continuous? No. The SOT89 tab limits continuous current to around 3 A in still air at 65 milliohm.

What is the usual packing? SOT89 normally ships on a 1000 piece reel. We confirm the reel and the marking on the quotation.