Contact Us

LTM8048EY#PBF

Brand: Analog Devices
Analog Devices LTM8048EY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8048EY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8048EY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8048EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8048EY: the isolated rail with the post regulator, guaranteed from zero degrees

The LTM8048EY#PBF is the commercial grade of the isolated flyback module with a linear post regulator: 3.1 V to 32 V in, a 725 VDC barrier, 2.5 V to 13 V out on the flyback side at up to 440 mA, and 1.2 V to 12 V at up to 300 mA after the regulator. The transformer, the switches and the controller are inside the 11.25 mm by 9 mm by 4.92 mm body. The electrical limits are the same as the industrial code; the guarantee is what moves, and it starts at 0 degrees rather than at -40.

Published values

ParameterValue
Input range3.1 V to 32 V
Isolation725 VDC, one second each polarity
Flyback output2.5 V to 13 V at up to 440 mA, set by one resistor
Post regulator1.2 V to 12 V at up to 300 mA, 0.25 V to 0.43 V of dropout
Post regulator noise20 microvolts RMS with a 0.01 microfarad bypass
Guaranteed range0 to +125 degrees internal; -40 assured by characterisation
Quiescent current850 microamps not switching, 1 microamp shut down
Load regulation1.5 percent on the flyback output, 2 mV to 10 mV on the regulator
BIASmay be tied to VIN; 3.1 V minimum, 8 mA at 12 V in
Thermal23.2 degrees per watt to ambient, 5.8 to the board
Package45 lead BGA, 11.25 mm by 9 mm by 4.92 mm, MSL 3, 1.1 g
Storage-55 to +125 degrees

A room temperature start covers the industrial switch and the instrument

Industrial switches, sensor interfaces and bench instruments are started in a room, and the ambient inside the enclosure is the number that matters. A 40 degree inlet with no airflow over the board can put 70 degrees at the package, which leaves 55 degrees of junction headroom and, through 23.2 degrees per watt, 2.37 W for the flyback and the regulator together. The E grade is fully specified at that point.

The application that does not fit is the outdoor cabinet, the pole mounted unit and the cold store. Those start below freezing, and the E grade only promises behaviour from 0 degrees upward even though the part will usually start. The honest way to handle it is to read the product specification's lowest operating temperature rather than the room the prototype was tested in.

Breaking a ground loop without giving up a quiet rail

The reason to pay for a barrier is a ground difference between two ends of a cable. A sensor at one end and an acquisition card at the other share a return that carries motor current, and the resulting offset appears in series with a millivolt signal. An isolated supply breaks that path at the supply, and the post regulator keeps the secondary quiet enough that the isolation does not simply move the noise to a different node.

Two things have to be checked on a real installation: the continuous voltage between the two grounds, which the hipot figure does not answer, and the capacitance across the barrier, which sets how much common mode current a fast transient will push through. Both are system questions, but they decide whether an isolated module solves the problem or relocates it.

The two grades on one order line

The E and I codes both appear over -40 to +125 in the order table and carry the same part marking, so a substitution cannot be spotted by eye. The grade lives on the reel label and in the test record. A product that is specified to start at minus 10 needs the I code or a written statement, and a product that is specified from 0 upward can take the E code without losing anything it was promised.

Tin lead and SAC305 are separate order lines as well, and the MP grade at -55 degrees exists in both finishes. A build that mixes finishes on one assembly is a reflow question long before it is a temperature question.

The pages that answer this most often are how to verify a drop in replacement for the family alternatives, the power management cross reference for the acceptance test, and vendor consolidation for the case where a replacement has to be fitted before the next build.

Two questions buyers ask about the isolated E grade

Is the flyback output current the same as the post regulator current? No. The flyback delivers up to 440 mA at 2.5 V, and the regulator delivers up to 300 mA, and the flyback has to carry the regulator current plus its own quiescent. At 300 mA out of the regulator the flyback is the limit at the top of the input range.

What happens if the secondary is shorted? The data sheet gives 30 mA of input short circuit current with the flyback output shorted, so the module limits rather than delivering full current into a fault. Recovery is automatic once the short is removed.