LTM4622IY#PBF
Product Specifications
LTM4622IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4622IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTM4622IY#PBF: six watts out of thirty nine square millimetres
The LTM4622 is a dual step down module that puts the controller, the switches, the inductor and the compensation inside one 6.25 by 6.25 mm package that is 1.82 mm tall. It takes 3.6 V to 20 V in, produces 0.6 V to 5.5 V out on each channel, delivers 2.5 A per channel continuously with 3 A peaks, or 5 A from a single combined output, and holds total output error to plus or minus 1.5 percent over load, line and temperature. Only input and output capacitors are needed outside the package.
What the vendor page states
| Parameter | Value |
|---|---|
| Input range | 3.6 V to 20 V, 3.3 V rail usable with the bias pin tied to the input |
| Output range | 0.6 V to 5.5 V per channel |
| Current | dual 2.5 A with 3 A peaks, or 5 A combined |
| Regulation | plus or minus 1.5 percent total over load, line and temperature |
| Control | current mode, external frequency synchronization |
| Parallel | multiphase with current sharing |
| Features | output tracking, soft start, selectable burst mode, power good |
| Protection | input overvoltage and overtemperature |
| Package | 6.25 by 6.25 by 1.82 mm land grid array, or 2.42 mm ball grid array |
Thirty nine square millimetres, five amps and 128 milliamps per square millimetre
The footprint is 39.06 square millimetres and the volume 71 cubic millimetres. Five amps in that footprint is 128 mA per square millimetre, and at 1.2 V out it is 6 W of delivered power. At 85 percent efficiency the heat is 1.06 W, at 88 percent 0.82 W, and at 90 percent 0.67 W, which works out to 27, 21 and 17 mW per square millimetre. Those numbers, not the current rating, decide whether the module runs cool: a 39 square millimetre part with 0.8 W in it needs the board copper underneath to spread the heat, and a board that gives it two thin traces will run 30 to 40 C hotter than the datasheet curves suggest.
Six percent duty at the top of the input range
Twenty volts in and 1.2 V out is a duty cycle of 6 percent, and a current mode converter at that duty has very little time to deliver the inductor current each cycle. The module's internal inductor and compensation are fixed, so the usable input range for a given output depends on the switching frequency and on the minimum on time. Running 20 V into 1.2 V at 2.5 A is within the published envelope, but a buyer should check the efficiency curve at that operating point rather than at the 12 V point, because the two differ by several points and the difference is heat.
Two rails or one, and the tracking pin
Used as two channels, the part produces 11.25 W total at 2.5 A on 1.2 V and 2.5 A on 3.3 V, and the tracking pin lets the second rail come up behind the first, which is what a processor with a core and an input output rail needs. Used as one channel, the two outputs parallel with current sharing and give 5 A. The choice changes the external parts count and the sequencing, and it has to be made before the board is laid out because the two channels share the same output capacitor bank in the combined case.
Before the order goes out
The 1.5 percent total error band is a full specification over load, line and temperature rather than a room temperature number, and on a 1.2 V rail it is 18 mV while on a 3.3 V rail it is 49.5 mV, so a load that needs a tighter window than that needs remote sense or a different part. The power management cross reference lists the module alternatives by input, output and current, the lead time page is where to check when the land grid array package is on allocation, and the analog and mixed signal category page holds the rest of the power family.
Request Quote — In Stock, 100% New & Original, Full Warranty