AD7795BRUZ-REEL
Product Specifications
AD7795BRUZ-REEL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7795BRUZ-REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD7795BRUZ-REEL: six differential channels at 16 bits, and the noise floor underneath them
The AD7795BRUZ-REEL is the 16-bit member of the AD7794 family, a complete analog front end for slow precision measurement. It carries six differential inputs, a low noise instrumentation amplifier with programmable gain, a band gap reference and a three wire serial port in a 24-lead TSSOP. The 24-bit sibling shares the same analog core, which is why the noise figures on the family sheet describe both parts.
What the vendor publishes
| Parameter | Value |
|---|---|
| Resolution | 16 bit, the AD7794 is the 24-bit version |
| Inputs | 6 differential |
| Front end | low noise instrumentation amplifier, programmable gain |
| Reference | internal band gap, 4 ppm per degree C typical, two external references accepted |
| Output rate | 4.17 Hz to 470 Hz |
| Noise | 40 nV rms at 4.17 Hz, 85 nV rms at 16.7 Hz |
| Supply current | 400 microamp typical, 1 microamp maximum in power down |
| Supply | 2.7 V to 5.25 V, separate interface supply |
| Rejection | 50 Hz and 60 Hz at the same time |
| Extras | programmable current sources, burnout currents, bias generator, low side power switch |
| Interface | 3 wire SPI, QSPI, MICROWIRE and DSP compatible |
| Temperature | B grade -40 to +105 C |
The noise floor against one 16-bit LSB
With a 2.5 V reference one LSB at 16 bits is 38.15 microvolts. The family noise is 40 nV rms at 4.17 Hz and 85 nV rms at 16.7 Hz, which is one thousandth of an LSB and two thousandths of an LSB. Put plainly, at the slow rates the converter is not what limits the measurement: the sensor, the reference and the cold junction take that role, and the 16-bit output word is comfortable.
That changes what the buyer is paying for. It is not the code count, it is the instrumentation amplifier in front of the modulator and the rejection that comes with a sigma delta. A 16-bit converter without a low noise front end needs an external amplifier, a filter and a reference, which is three more parts and three more error terms on a board that has to fit.
Six channels on one modulator
There is one converter inside and a multiplexer in front of it, so the six channels share the output rate. At 470 Hz each channel is seen 78 times a second. At 16.7 Hz each channel is seen 2.8 times a second. A process weighing six load cells at 10 readings per second each needs 60 Hz of total output rate, which the part reaches, and a temperature logger at one reading per second per channel needs 6 Hz, which is below the slowest setting and has to be built by sequencing channels on a timer.
Switching channels has a cost: the input capacitance of the new channel has to charge, and the first conversion after a channel change is not settled. Most systems discard one reading after each change, which cuts the effective rate by half in a six channel scan.
Why the line rejection and the burnout currents matter
Rejecting 50 Hz and 60 Hz at the same time means one product works in Europe and in North America without a filter setting change, and a scale built in one country does not read differently in the other. The burnout current sources inject a small current into the sensor and read the resulting voltage, so an open thermocouple or a broken bridge wire is detected as a fault instead of being reported as a valid reading near zero. The low side power switch removes power from a bridge between conversions, which is how a battery powered transmitter lasts years.
Two questions buyers ask
Should the order be 16 bit or 24 bit? Take 16 bit when the sensor and the reference together cannot support better than 16 bits, which is true of most thermocouples, pressure sensors and 0.1 percent bridges. Take the 24-bit part when the signal is a load cell used at low counts or a chromatograph, where the extra codes are used. The pinout and the package are the same, so the decision is made on the signal, not on the board.
Does it need an external reference? The internal band gap at 4 ppm per degree C typical is enough for most industrial measurements. For a ratiometric bridge the better answer is to use the bridge excitation as the reference, so the excitation drift cancels in the reading, and the part accepts two external differential references for exactly that.
SUPERB quotes the AD7795BRUZ-REEL against this row and confirms the B or C grade before shipment. The converter choice is compared under ADC DAC cross reference. A build waiting on a long lead time part is covered by component lead time solutions, and stock sits in the analog and mixed signal ICs index.
Request Quote — In Stock, 100% New & Original, Full Warranty