The LTM4630IY-1A#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4630IY-1A#PBF: the suffix on the order code and a 36 A rail from 12 V
The LTM4630IY-1A#PBF is an order code in the dual 18 A module family, in the 16 mm by 16 mm by 4.41 mm ball grid array with SAC305 balls and MSL 3. The family takes 4.5 V to 15 V in and delivers 0.6 V to 1.8 V per channel at 18 A, or 36 A with the channels tied, with 1.5 percent total DC error and multiphase operation up to 144 A. The -1A suffix is a variant of the base part, and the ratings in this block are the family's published figures rather than a claim about what that suffix changes.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 4.5 V to 15 V |
| Output voltage | 0.6 V to 1.8 V per channel |
| Output current | 18 A per channel, 36 A with channels tied |
| Multiphase | up to eight modules, 144 A |
| Total DC error | 1.5 percent over line, load and temperature |
| Minimum on time | 90 ns |
| Current limit | 30 A per channel |
| Junction to ambient | 7 C/W, 1.5 C/W to case bottom |
| Package | 16 mm x 16 mm x 4.41 mm BGA, 3.2 g |
| Temperature range | -40 C to 125 C, I grade |
The suffix has to be traced before the order goes out
The base document for this family covers LTM4630 and its pin compatible relatives, and it does not describe a -1A variant. That matters more than usual here because the -1A order code is a different reel with its own part marking, and the current limit, the foldback behaviour and the soft start are the fields a variant most often changes.
A buyer holding a requirement written against the base part should ask for the -1A document and check those three fields before releasing the order. Quoting the family ratings and shipping the variant is how a 30 A current limit becomes an 18 A one, or the reverse, without anyone noticing until the fault test.
36 A in one package and 7 C/W
The package is 16 mm by 16 mm and quoted at 7 C/W junction to ambient with 1.5 C/W to the case bottom, which is the best thermal path in this family by a wide margin. The vendor's own thermal example works backwards from a measured rise: 34 C over 5.5 W gives 6.2 C/W and 48 C over 7.9 W gives 6.0 C/W, both close to the tabulated 7 C/W.
At 12 V to 1.2 V and 18 A a channel is 21.6 W out and 2.4 W of loss at 90 percent, a 16.8 C rise. Two channels at 43.2 W out are about 4.8 W of loss, which is 34 C, and that is the number the vendor's example is measuring. A 40 C rise in a 16 mm package with a 1.5 C/W path to the board is a board question rather than a module question.
The 90 ns on-time floor
At 12 V in and 0.6 V out the duty cycle is 5 percent, so 90 ns of on time corresponds to 1.8 us and a frequency ceiling of about 555 kHz. At 0.9 V the duty cycle is 7.5 percent and the ceiling moves to 833 kHz, and at 1.8 V it is 15 percent and 1.67 MHz.
A rail at 0.6 V from a 12 V bus therefore cannot use the top of the frequency range, and a board that specifies 1 MHz for a 0.6 V rail is asking the module for a 50 ns on time it does not have. The same module on a 5 V bus has three times the duty cycle and three times the frequency headroom.
Multiphase, and what 144 A needs around it
Eight modules in multiphase reach 144 A with current sharing and frequency synchronisation, which is how a 1 V rail at 100 A is built from parts that each carry 18 A. The sharing is set by the pin to pin connection between the modules and by the same feedback resistor in each, which is why the vendor's note about using one resistor value for a parallel arrangement matters.
At 144 A the interconnect and the capacitor bank are the engineering, not the modules. A 1 V rail at 100 A is 100 W and a 90 percent figure means 11 W of loss spread over six modules, which is 1.8 W each, so each package sees a 13 C rise and the board sees the sum.
Where a customer needs a second position on this part, the power management cross reference is the starting point, the ADI second source page sets out the checks a substitution has to pass, and BOM shortage recovery is the short lead time route we quote against.
Two questions buyers ask
Are the family ratings valid for the -1A code? Not automatically. The ratings quoted here are the base family's. The current limit, foldback and soft start are the fields a variant most often changes, so the -1A document has to be checked before release.
What limits a 0.6 V rail at 12 V in? The 90 ns minimum on time. A 5 percent duty cycle puts the frequency ceiling at about 555 kHz, whatever the resistor on the frequency pin asks for.